Deeper may not be better: relationship between catheter dysfunction and location of the catheter tip in right-sided tunnelled haemodialysis catheters. Issue 9 (September 2022)
- Record Type:
- Journal Article
- Title:
- Deeper may not be better: relationship between catheter dysfunction and location of the catheter tip in right-sided tunnelled haemodialysis catheters. Issue 9 (September 2022)
- Main Title:
- Deeper may not be better: relationship between catheter dysfunction and location of the catheter tip in right-sided tunnelled haemodialysis catheters
- Authors:
- Soh, N.Y.T.
Tan, B.S.
Chan, S.J.M.
Patel, A.
Gogna, A.
Zhuang, K.D.
Tashi, S.
Venkatanarasimha, N.
Tay, K.H.
Chandramohan, S. - Abstract:
- Abstract : Aim: To examine the relationship between catheter tip location and catheter dysfunction in the context of tunnelled central venous catheters (CVCs) for haemodialysis. Materials and methods: This was a retrospective study of 993 haemodialysis patients who underwent insertion of tunnelled CVCs of step-tip design via the right internal jugular vein (IJV). Based on intra-procedural radiographs, the catheter tip was characterised as being in the superior vena cava (SVC), cavo-atrial junction (CAJ), or deep right atrium (DRA). Patients were tracked for 90 days post-procedure for complications resulting in catheter replacement, and these were compared between cohorts. Statistical analysis was performed with Pearson's chi-square and Fisher's exact tests for categorical variables and two-sample t-test and one-way analysis of variance (ANOVA) for continuous variables. Results: Ninety-five patients (9.6%) experienced catheter dysfunction necessitating replacement within 90 days of insertion. Tip location in SVC was associated with lower occurrence of catheter dysfunction (1.9%) as compared with the CAJ (8%) and DRA (11%; p= 0.049). Catheter replacement due to other complications (catheter-associated bacteraemia, cuff dislodgement, exit-site infection, external catheter damage) showed no statistically significant relation to location of the CVC tip. Conclusion: When utilising tunnelled CVCs with a step-tip design inserted via the right IJV, location of the catheter tip in theAbstract : Aim: To examine the relationship between catheter tip location and catheter dysfunction in the context of tunnelled central venous catheters (CVCs) for haemodialysis. Materials and methods: This was a retrospective study of 993 haemodialysis patients who underwent insertion of tunnelled CVCs of step-tip design via the right internal jugular vein (IJV). Based on intra-procedural radiographs, the catheter tip was characterised as being in the superior vena cava (SVC), cavo-atrial junction (CAJ), or deep right atrium (DRA). Patients were tracked for 90 days post-procedure for complications resulting in catheter replacement, and these were compared between cohorts. Statistical analysis was performed with Pearson's chi-square and Fisher's exact tests for categorical variables and two-sample t-test and one-way analysis of variance (ANOVA) for continuous variables. Results: Ninety-five patients (9.6%) experienced catheter dysfunction necessitating replacement within 90 days of insertion. Tip location in SVC was associated with lower occurrence of catheter dysfunction (1.9%) as compared with the CAJ (8%) and DRA (11%; p= 0.049). Catheter replacement due to other complications (catheter-associated bacteraemia, cuff dislodgement, exit-site infection, external catheter damage) showed no statistically significant relation to location of the CVC tip. Conclusion: When utilising tunnelled CVCs with a step-tip design inserted via the right IJV, location of the catheter tip in the SVC is associated with reduced occurrence of catheter dysfunction as compared to either the CAJ or DRA. Highlights: CVC tip in the SVC is associated with lower incidence of catheter dysfunction. In the context of tunneled CVCs for haemodialysis When utilising a step-tip catheter design inserted via the right IJV Largest study to date examining this relationship … (more)
- Is Part Of:
- Clinical radiology. Volume 77:Issue 9(2022)
- Journal:
- Clinical radiology
- Issue:
- Volume 77:Issue 9(2022)
- Issue Display:
- Volume 77, Issue 9 (2022)
- Year:
- 2022
- Volume:
- 77
- Issue:
- 9
- Issue Sort Value:
- 2022-0077-0009-0000
- Page Start:
- 678
- Page End:
- 683
- Publication Date:
- 2022-09
- Subjects:
- Medical radiology -- Periodicals
Radiotherapy -- Periodicals
Radiotherapy -- Periodicals
Radiology -- Periodicals
Societies, Medical -- Periodicals
Medical radiology
Radiotherapy
Electronic journals
Periodicals
616.0757 - Journal URLs:
- http://www.sciencedirect.com/science/journal/00099260 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.crad.2022.04.020 ↗
- Languages:
- English
- ISSNs:
- 0009-9260
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3286.350000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 23044.xml