"Comparative intra‐ and inter‐rater reliability of maximal voluntary contraction with unidigital and bidigital vaginal palpation and construct validity with Peritron manometer". Issue 2 (24th December 2019)
- Record Type:
- Journal Article
- Title:
- "Comparative intra‐ and inter‐rater reliability of maximal voluntary contraction with unidigital and bidigital vaginal palpation and construct validity with Peritron manometer". Issue 2 (24th December 2019)
- Main Title:
- "Comparative intra‐ and inter‐rater reliability of maximal voluntary contraction with unidigital and bidigital vaginal palpation and construct validity with Peritron manometer"
- Authors:
- Silva, Jordana B. da
Sato, Tatiana O.
Rocha, Ana P. R.
Driusso, Patricia - Abstract:
- Abstract: Aims: Evaluate the intra‐ and inter‐rater reliability of maximal voluntary contraction (MVC) of pelvic floor muscle (PFM) assessment by unidigital and bidigital vaginal palpation. As a secondary aim, evaluate the construct validity of vaginal palpation and a manometer. Methods: A total of 120 women were recruited and allocated into three groups according to age (group 1 [G1]: 18‐35; G2: 36‐59; G3: ≥60 years). Examiner A conducted an interview and examiners B and C performed evaluations of PFM function using both unidigital and bidigital vaginal palpation. Seven to 10 days later, examiner B repeated both types of vaginal palpation and measured the MVC pressure with a Peritron. Reliability was analyzed using Cohen's linear weighted Kappa ( κ w ). The construct validity was calculated using the Spearman's correlation ( r s ). Results: Intra‐rater reliability of unidigital and bidigital palpation was κ w = 0.75 and κ w = 0.58 in G1, κ w = 0.59 and κ w = 0.73 in G2, and κ w = 0.79 and κ w = 0.86 in G3, respectively. Inter‐rater reliability of unidigital and bidigital palpation was κ w = 0.52 and κ w = 0.48 in G1, κ w = 0.47 and κ w = 0.52 in G2, and κ w = 0.50 and κ w = 0.64 in G3, respectively. Spearman's correlation coefficients were significant at r s = 0.79 and r s = 0.80 for unidigital and bidigital vaginal palpation, respectively. Conclusions: Unidigital or bidigital vaginal palpation were indicated to evaluate G1 and G2 but bidigital palpation wasAbstract: Aims: Evaluate the intra‐ and inter‐rater reliability of maximal voluntary contraction (MVC) of pelvic floor muscle (PFM) assessment by unidigital and bidigital vaginal palpation. As a secondary aim, evaluate the construct validity of vaginal palpation and a manometer. Methods: A total of 120 women were recruited and allocated into three groups according to age (group 1 [G1]: 18‐35; G2: 36‐59; G3: ≥60 years). Examiner A conducted an interview and examiners B and C performed evaluations of PFM function using both unidigital and bidigital vaginal palpation. Seven to 10 days later, examiner B repeated both types of vaginal palpation and measured the MVC pressure with a Peritron. Reliability was analyzed using Cohen's linear weighted Kappa ( κ w ). The construct validity was calculated using the Spearman's correlation ( r s ). Results: Intra‐rater reliability of unidigital and bidigital palpation was κ w = 0.75 and κ w = 0.58 in G1, κ w = 0.59 and κ w = 0.73 in G2, and κ w = 0.79 and κ w = 0.86 in G3, respectively. Inter‐rater reliability of unidigital and bidigital palpation was κ w = 0.52 and κ w = 0.48 in G1, κ w = 0.47 and κ w = 0.52 in G2, and κ w = 0.50 and κ w = 0.64 in G3, respectively. Spearman's correlation coefficients were significant at r s = 0.79 and r s = 0.80 for unidigital and bidigital vaginal palpation, respectively. Conclusions: Unidigital or bidigital vaginal palpation were indicated to evaluate G1 and G2 but bidigital palpation was more reliable in G3 when two examiners performed the evaluation. For the assessment conducted by one examiner, unidigital palpation was more reliable in G1 while bidigital palpation was more reliable in G2 and G3. Both unidigital and bidigital palpation have high measures of validity. … (more)
- Is Part Of:
- Neurourology and urodynamics. Volume 39:Issue 2(2020:Feb.)
- Journal:
- Neurourology and urodynamics
- Issue:
- Volume 39:Issue 2(2020:Feb.)
- Issue Display:
- Volume 39, Issue 2 (2020)
- Year:
- 2020
- Volume:
- 39
- Issue:
- 2
- Issue Sort Value:
- 2020-0039-0002-0000
- Page Start:
- 721
- Page End:
- 731
- Publication Date:
- 2019-12-24
- Subjects:
- manometry -- outcome and process assessment -- palpation -- pelvic floor -- reproducibility of results -- strength
Urinary organs -- Periodicals
Urodynamics -- Periodicals
Urology -- Periodicals
616.6 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1520-6777 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/nau.24263 ↗
- Languages:
- English
- ISSNs:
- 0733-2467
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6081.589000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 23030.xml