A simple method to detect leaks after left atrial appendage occlusion with Watchman. (10th July 2020)
- Record Type:
- Journal Article
- Title:
- A simple method to detect leaks after left atrial appendage occlusion with Watchman. (10th July 2020)
- Main Title:
- A simple method to detect leaks after left atrial appendage occlusion with Watchman
- Authors:
- Ayhan, Hüseyin
Mohanty, Sanghamitra
Gedikli, Ömer
Trivedi, Chintan
Canpolat, Ugur
Tapia, Alfredo Chauca
Chen, Qiong
Della Rocca, Domenico G.
Gianni, Carola
Salwan, Anu
Annanab, Alisara
MacDonald, Bryan
Mayedo, Angel
Burkhardt, J. David
Horton, Rodney
Gallinghouse, Gerald J.
Di Biase, Luigi
Al‐Ahmad, Amin
Natale, Andrea - Abstract:
- Abstract: Background: We evaluated the efficacy of a new method in identifying peri‐device leak (PDL) using morphology of the thrombus formed inside the left atrial appendage (LAA) as seen on follow‐up transesophageal echo (TEE). Method: A total of 291 consecutive patients undergoing Watchman procedure were included in this analysis. TEE was performed at 45 days postprocedure. Based on the presence of the thrombus inside the LAA behind the device, patients were grouped as (1) white (W) group: LAA completely filled with thrombus ( n = 101), 2) nonwhite (NW) group: LAA completely black or mixed (part black and part white; n = 190). Follow‐up TEE was repeated at 6 and 12 months. Results: Baseline characteristics were comparable between groups except the device size, number of patients with chicken‐wing morphology, and prevalence of left atrial "smoke" that were significantly higher in the NW group. Detection of black appearance was comparable between the pre‐coil closure image and the NW population (26/36 [72.2%] vs 99/154 [64.3%], p = .37). After adjusting for clinically relevant covariates, NW appearance of the LAA was associated with the presence of significant leak (odds ratio: 47.96, 95% confidence interval: 2.91–790.2, p < .001). The 11 patients with mixed appearance at the 6‐month TEE remained unchanged (part black and part white) at the 12‐month TEE. LAA appearance was white in all 36 patients following coil closure. Conclusion: Our findings demonstrated white andAbstract: Background: We evaluated the efficacy of a new method in identifying peri‐device leak (PDL) using morphology of the thrombus formed inside the left atrial appendage (LAA) as seen on follow‐up transesophageal echo (TEE). Method: A total of 291 consecutive patients undergoing Watchman procedure were included in this analysis. TEE was performed at 45 days postprocedure. Based on the presence of the thrombus inside the LAA behind the device, patients were grouped as (1) white (W) group: LAA completely filled with thrombus ( n = 101), 2) nonwhite (NW) group: LAA completely black or mixed (part black and part white; n = 190). Follow‐up TEE was repeated at 6 and 12 months. Results: Baseline characteristics were comparable between groups except the device size, number of patients with chicken‐wing morphology, and prevalence of left atrial "smoke" that were significantly higher in the NW group. Detection of black appearance was comparable between the pre‐coil closure image and the NW population (26/36 [72.2%] vs 99/154 [64.3%], p = .37). After adjusting for clinically relevant covariates, NW appearance of the LAA was associated with the presence of significant leak (odds ratio: 47.96, 95% confidence interval: 2.91–790.2, p < .001). The 11 patients with mixed appearance at the 6‐month TEE remained unchanged (part black and part white) at the 12‐month TEE. LAA appearance was white in all 36 patients following coil closure. Conclusion: Our findings demonstrated white and nonwhite appearance of the appendage on TEE to be reliable markers of complete closure and leak respectively, following LAA occlusion with the Watchman device. … (more)
- Is Part Of:
- Journal of cardiovascular electrophysiology. Volume 31:Number 9(2020)
- Journal:
- Journal of cardiovascular electrophysiology
- Issue:
- Volume 31:Number 9(2020)
- Issue Display:
- Volume 31, Issue 9 (2020)
- Year:
- 2020
- Volume:
- 31
- Issue:
- 9
- Issue Sort Value:
- 2020-0031-0009-0000
- Page Start:
- 2338
- Page End:
- 2343
- Publication Date:
- 2020-07-10
- Subjects:
- leak -- left atrial appendage (LAA) -- thrombus -- transoesophageal echocardiography (TEE) -- Watchman
Blood vessels -- Physiology -- Periodicals
Electrophysiology -- Periodicals
Heart -- Physiology -- Periodicals
612.1 - Journal URLs:
- http://onlinelibrary.wiley.com/ ↗
- DOI:
- 10.1111/jce.14641 ↗
- Languages:
- English
- ISSNs:
- 1045-3873
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4954.866000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 23036.xml