An optimized and highly repeatable MRI acquisition and processing pipeline for quantitative susceptibility mapping in the head‐and‐neck region. Issue 6 (3rd July 2020)
- Record Type:
- Journal Article
- Title:
- An optimized and highly repeatable MRI acquisition and processing pipeline for quantitative susceptibility mapping in the head‐and‐neck region. Issue 6 (3rd July 2020)
- Main Title:
- An optimized and highly repeatable MRI acquisition and processing pipeline for quantitative susceptibility mapping in the head‐and‐neck region
- Authors:
- Karsa, Anita
Punwani, Shonit
Shmueli, Karin - Abstract:
- Abstract : Purpose: Quantitative Susceptibility Mapping (QSM) is an emerging technique sensitive to disease‐related changes including oxygenation. It is extensively used in brain studies and has increasing clinical applications outside the brain. Here we present the first MRI acquisition protocol and QSM pipeline optimized for the head‐and‐neck region together with a repeatability analysis performed in healthy volunteers. Methods: We investigated both the intrasession and the intersession repeatability of the optimized method in 10 subjects. We also implemented two, Tikhonov‐regularisation‐based susceptibility calculation techniques that were found to have higher contrast‐to‐noise than existing methods in the head‐and‐neck region. Repeatability was evaluated by calculating the distributions of susceptibility differences between repeated scans and the corresponding minimum detectable effect sizes (MDEs). Results: Deep brain regions had higher QSM repeatability than neck regions. As expected, intrasession repeatability was generally better than intersession repeatability. Susceptibility maps calculated using projection onto dipole fields for background field removal were more repeatable than using the Laplacian boundary value method in the head‐and‐neck region. Small (short‐axis diameter <5 mm) lymph nodes had the lowest repeatability (MDE = 0.27 ppm) as imperfect segmentation included some of the surrounding paramagnetic fatty fascia, highlighting the importance of accurateAbstract : Purpose: Quantitative Susceptibility Mapping (QSM) is an emerging technique sensitive to disease‐related changes including oxygenation. It is extensively used in brain studies and has increasing clinical applications outside the brain. Here we present the first MRI acquisition protocol and QSM pipeline optimized for the head‐and‐neck region together with a repeatability analysis performed in healthy volunteers. Methods: We investigated both the intrasession and the intersession repeatability of the optimized method in 10 subjects. We also implemented two, Tikhonov‐regularisation‐based susceptibility calculation techniques that were found to have higher contrast‐to‐noise than existing methods in the head‐and‐neck region. Repeatability was evaluated by calculating the distributions of susceptibility differences between repeated scans and the corresponding minimum detectable effect sizes (MDEs). Results: Deep brain regions had higher QSM repeatability than neck regions. As expected, intrasession repeatability was generally better than intersession repeatability. Susceptibility maps calculated using projection onto dipole fields for background field removal were more repeatable than using the Laplacian boundary value method in the head‐and‐neck region. Small (short‐axis diameter <5 mm) lymph nodes had the lowest repeatability (MDE = 0.27 ppm) as imperfect segmentation included some of the surrounding paramagnetic fatty fascia, highlighting the importance of accurate region delineation. MDEs in the larger lymph nodes (0.16 ppm), submandibular glands (0.10 ppm), and especially the parotid glands (0.06 ppm) were much lower, comparable to those of the brain regions. Conclusions: The high repeatability of the acquisition and pipeline optimized for QSM will facilitate clinical studies in the head‐and‐neck region. … (more)
- Is Part Of:
- Magnetic resonance in medicine. Volume 84:Issue 6(2020)
- Journal:
- Magnetic resonance in medicine
- Issue:
- Volume 84:Issue 6(2020)
- Issue Display:
- Volume 84, Issue 6 (2020)
- Year:
- 2020
- Volume:
- 84
- Issue:
- 6
- Issue Sort Value:
- 2020-0084-0006-0000
- Page Start:
- 3206
- Page End:
- 3222
- Publication Date:
- 2020-07-03
- Subjects:
- head and neck -- lymph node -- parotid gland -- QSM -- repeatability -- submandibular gland -- susceptibility mapping
Nuclear magnetic resonance -- Periodicals
Electron paramagnetic resonance -- Periodicals
616.07548 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-2594 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/mrm.28377 ↗
- Languages:
- English
- ISSNs:
- 0740-3194
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5337.798000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 23038.xml