Feasibility of a novel mapping system combined with remote magnetic navigation for catheter ablation of premature ventricular contractions. Issue 2 (31st January 2019)
- Record Type:
- Journal Article
- Title:
- Feasibility of a novel mapping system combined with remote magnetic navigation for catheter ablation of premature ventricular contractions. Issue 2 (31st January 2019)
- Main Title:
- Feasibility of a novel mapping system combined with remote magnetic navigation for catheter ablation of premature ventricular contractions
- Authors:
- Dang, Shipeng
Jons, Christian
Jacobsen, Peter Karl
Pehrson, Steen
Chen, Xu - Abstract:
- Abstract: Background: Remote magnetic navigation (RMN) is often used in combination with a 3‐dimensional mapping system to perform catheter ablations. This study aim to investigate the feasibility and effectiveness of a novel 3D‐mapping system, EnSite Precision, combined with RMN for catheter ablation of premature ventricular contractions (PVCs), and compared it to the procedures performed by CARTO3 with RMN. Methods: Forty‐three consecutive PVC patients were either ablated with the guidance of EnSite Precision (n = 22) or CARTO (n = 21) navigated by RMN. Procedure‐related details, acute and long‐term success were assessed. Results: Patient characteristics between both the groups were similar (age: 47.1 ± 19.8 vs 47.1 ± 12.7, female: 63.6% vs 57.1%). No significant difference was found in the procedure time (99.5 ± 30.4 vs 92.9 ± 24.8 min, P = 0.436), mapping time (18.6 ± 12.8 vs 15.5 ± 10.2 min, P = 0.390), radiofrequency ablation time (333.4 ± 267.0 vs 469.3 ± 343.1 s, P = 0.154), fluoroscopy time (4.0 ± 1.9 vs 3.8 ± 2.0 min, P = 0.635), and X‐ray dose (1.8 ± 1.4 vs 2.0 ± 1.2 Gycm 2, P = 0.649) between the two groups. No significant procedural complication occurred in either group. In addition, there was no significant differences regarding the acute success rate (90.9% vs 90.5%, P = 0.961) and long‐term success rate (86.4% vs 81.0%, P = 0.631) after 16.2 ± 6.2 months of follow‐up between the two groups. Conclusions: RMN combined with EnSite PrecisionAbstract: Background: Remote magnetic navigation (RMN) is often used in combination with a 3‐dimensional mapping system to perform catheter ablations. This study aim to investigate the feasibility and effectiveness of a novel 3D‐mapping system, EnSite Precision, combined with RMN for catheter ablation of premature ventricular contractions (PVCs), and compared it to the procedures performed by CARTO3 with RMN. Methods: Forty‐three consecutive PVC patients were either ablated with the guidance of EnSite Precision (n = 22) or CARTO (n = 21) navigated by RMN. Procedure‐related details, acute and long‐term success were assessed. Results: Patient characteristics between both the groups were similar (age: 47.1 ± 19.8 vs 47.1 ± 12.7, female: 63.6% vs 57.1%). No significant difference was found in the procedure time (99.5 ± 30.4 vs 92.9 ± 24.8 min, P = 0.436), mapping time (18.6 ± 12.8 vs 15.5 ± 10.2 min, P = 0.390), radiofrequency ablation time (333.4 ± 267.0 vs 469.3 ± 343.1 s, P = 0.154), fluoroscopy time (4.0 ± 1.9 vs 3.8 ± 2.0 min, P = 0.635), and X‐ray dose (1.8 ± 1.4 vs 2.0 ± 1.2 Gycm 2, P = 0.649) between the two groups. No significant procedural complication occurred in either group. In addition, there was no significant differences regarding the acute success rate (90.9% vs 90.5%, P = 0.961) and long‐term success rate (86.4% vs 81.0%, P = 0.631) after 16.2 ± 6.2 months of follow‐up between the two groups. Conclusions: RMN combined with EnSite Precision mapping system is effective and safe for catheter ablation of PVCs. … (more)
- Is Part Of:
- Journal of arrhythmia. Volume 35:Issue 2(2019)
- Journal:
- Journal of arrhythmia
- Issue:
- Volume 35:Issue 2(2019)
- Issue Display:
- Volume 35, Issue 2 (2019)
- Year:
- 2019
- Volume:
- 35
- Issue:
- 2
- Issue Sort Value:
- 2019-0035-0002-0000
- Page Start:
- 244
- Page End:
- 251
- Publication Date:
- 2019-01-31
- Subjects:
- CARTO -- EnSite Precision -- premature ventricular contractions -- remote magnetic navigation
Arrhythmia -- Periodicals
Cardiac pacing -- Periodicals
Arrhythmias, Cardiac
Arrhythmia
Cardiac pacing
Periodicals
Electronic journals
Periodicals
616.128 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1883-2148/issues ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/joa3.12157 ↗
- Languages:
- English
- ISSNs:
- 1880-4276
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 22997.xml