Automatic contouring QA method using a deep learning–based autocontouring system. Issue 8 (17th May 2022)
- Record Type:
- Journal Article
- Title:
- Automatic contouring QA method using a deep learning–based autocontouring system. Issue 8 (17th May 2022)
- Main Title:
- Automatic contouring QA method using a deep learning–based autocontouring system
- Authors:
- Rhee, Dong Joo
Akinfenwa, Chidinma P. Anakwenze
Rigaud, Bastien
Jhingran, Anuja
Cardenas, Carlos E.
Zhang, Lifei
Prajapati, Surendra
Kry, Stephen F.
Brock, Kristy K.
Beadle, Beth M.
Shaw, William
O'Reilly, Frederika
Parkes, Jeannette
Burger, Hester
Fakie, Nazia
Trauernicht, Chris
Simonds, Hannah
Court, Laurence E. - Abstract:
- Abstract: Purpose: To determine the most accurate similarity metric when using an independent system to verify automatically generated contours. Methods: A reference autocontouring system (primary system to create clinical contours) and a verification autocontouring system (secondary system to test the primary contours) were used to generate a pair of 6 female pelvic structures (UteroCervix [uterus + cervix], CTVn [nodal clinical target volume (CTV)], PAN [para‐aortic lymph nodes], bladder, rectum, and kidneys) on 49 CT scans from our institution and 38 from other institutions. Additionally, clinically acceptable and unacceptable contours were manually generated using the 49 internal CT scans. Eleven similarity metrics (volumetric Dice similarity coefficient (DSC), Hausdorff distance, 95% Hausdorff distance, mean surface distance, and surface DSC with tolerances from 1 to 10 mm) were calculated between the reference and the verification autocontours, and between the manually generated and the verification autocontours. A support vector machine (SVM) was used to determine the threshold that separates clinically acceptable and unacceptable contours for each structure. The 11 metrics were investigated individually and in certain combinations. Linear, radial basis function, sigmoid, and polynomial kernels were tested using the combinations of metrics as inputs for the SVM. Results: The highest contouring error detection accuracies were 0.91 for the UteroCervix, 0.90 for theAbstract: Purpose: To determine the most accurate similarity metric when using an independent system to verify automatically generated contours. Methods: A reference autocontouring system (primary system to create clinical contours) and a verification autocontouring system (secondary system to test the primary contours) were used to generate a pair of 6 female pelvic structures (UteroCervix [uterus + cervix], CTVn [nodal clinical target volume (CTV)], PAN [para‐aortic lymph nodes], bladder, rectum, and kidneys) on 49 CT scans from our institution and 38 from other institutions. Additionally, clinically acceptable and unacceptable contours were manually generated using the 49 internal CT scans. Eleven similarity metrics (volumetric Dice similarity coefficient (DSC), Hausdorff distance, 95% Hausdorff distance, mean surface distance, and surface DSC with tolerances from 1 to 10 mm) were calculated between the reference and the verification autocontours, and between the manually generated and the verification autocontours. A support vector machine (SVM) was used to determine the threshold that separates clinically acceptable and unacceptable contours for each structure. The 11 metrics were investigated individually and in certain combinations. Linear, radial basis function, sigmoid, and polynomial kernels were tested using the combinations of metrics as inputs for the SVM. Results: The highest contouring error detection accuracies were 0.91 for the UteroCervix, 0.90 for the CTVn, 0.89 for the PAN, 0.92 for the bladder, 0.95 for the rectum, and 0.97 for the kidneys and were achieved using surface DSCs with a thickness of 1, 2, or 3 mm. The linear kernel was the most accurate and consistent when a combination of metrics was used as an input for the SVM. However, the best model accuracy from the combinations of metrics was not better than the best model accuracy from a surface DSC as an input. Conclusions: We distinguished clinically acceptable contours from clinically unacceptable contours with an accuracy higher than 0.9 for the targets and critical structures in patients with cervical cancer; the most accurate similarity metric was surface DSC with a thickness of 1, 2, or 3 mm. … (more)
- Is Part Of:
- Journal of applied clinical medical physics. Volume 23:Issue 8(2022)
- Journal:
- Journal of applied clinical medical physics
- Issue:
- Volume 23:Issue 8(2022)
- Issue Display:
- Volume 23, Issue 8 (2022)
- Year:
- 2022
- Volume:
- 23
- Issue:
- 8
- Issue Sort Value:
- 2022-0023-0008-0000
- Page Start:
- n/a
- Page End:
- n/a
- Publication Date:
- 2022-05-17
- Subjects:
- auto‐contour -- deep learning -- similarity metrics
Medical physics -- Periodicals
Clinical medicine -- Periodicals
Health Physics
Clinical Medicine
Electronic journals
Periodicals
Periodicals
Fulltext
Internet Resources
610.153 - Journal URLs:
- http://aapm.onlinelibrary.wiley.com/hub/journal/10.1002/(ISSN)1526-9914/ ↗
http://bibpurl.oclc.org/web/7294 ↗
http://www.jacmp.org/ ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/acm2.13647 ↗
- Languages:
- English
- ISSNs:
- 1526-9914
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 22977.xml