Development of a method based on thermal desorption-gas chromatography/mass spectrometry for the determination of 103 volatile organic compounds in mattresses. Issue 9 (14th July 2020)
- Record Type:
- Journal Article
- Title:
- Development of a method based on thermal desorption-gas chromatography/mass spectrometry for the determination of 103 volatile organic compounds in mattresses. Issue 9 (14th July 2020)
- Main Title:
- Development of a method based on thermal desorption-gas chromatography/mass spectrometry for the determination of 103 volatile organic compounds in mattresses
- Authors:
- Cao, Shurui
Wen, Yao
Xi, Cunxian
Li, Xianliang
Zhang, Lei
Wang, Guomin
Shang, Jingchuan - Abstract:
- ABSTRACT: A sensitive and reliable method based on environment test chamber coupled with thermal desorption and gas chromatography-mass spectrometry (ETC-TD-GC/MS) was developed and validated for the determination of 103 volatile organic compounds (VOCs) emitted from mattresses. In the study, two commercial sorbent tubes were compared in terms of adsorption efficiency towards the target analytes. The result illustrated that the multisorbent tubes containing Carbopack C, Carbopack B and Carboxen 1000 had better performance than Tenax TA tubes owing to their large surface area, low capacity for water and high temperature stability, which allowed a wide range of VOCs to be absorbed, especially for VOCs with low boiling points and small molecules. To achieve the optimum conditions for the analysis, several thermal desportion parameters were accurately investigated. Under the optimal conditions, the method showed good linearities, with correlation coefficients ranging from 0.9982 to 0.9999 and the method detection limits and method quantification limitsfor target compounds in the range of 0.006 ~ 0.561 µg/m 3 and 0.020 ~ 1.870 µg/m 3, respectively. In order to evaluate the performance of the developed method on real samples, various mattresses from different manufacturers were analysed. All mattress samples were found to emit VOCs and the values of area-specific emission rate (SERs) for total target compounds were in the range of 90.25 ~ 288.63 µg/m 2 ·h. Moreover, the SERs ofABSTRACT: A sensitive and reliable method based on environment test chamber coupled with thermal desorption and gas chromatography-mass spectrometry (ETC-TD-GC/MS) was developed and validated for the determination of 103 volatile organic compounds (VOCs) emitted from mattresses. In the study, two commercial sorbent tubes were compared in terms of adsorption efficiency towards the target analytes. The result illustrated that the multisorbent tubes containing Carbopack C, Carbopack B and Carboxen 1000 had better performance than Tenax TA tubes owing to their large surface area, low capacity for water and high temperature stability, which allowed a wide range of VOCs to be absorbed, especially for VOCs with low boiling points and small molecules. To achieve the optimum conditions for the analysis, several thermal desportion parameters were accurately investigated. Under the optimal conditions, the method showed good linearities, with correlation coefficients ranging from 0.9982 to 0.9999 and the method detection limits and method quantification limitsfor target compounds in the range of 0.006 ~ 0.561 µg/m 3 and 0.020 ~ 1.870 µg/m 3, respectively. In order to evaluate the performance of the developed method on real samples, various mattresses from different manufacturers were analysed. All mattress samples were found to emit VOCs and the values of area-specific emission rate (SERs) for total target compounds were in the range of 90.25 ~ 288.63 µg/m 2 ·h. Moreover, the SERs of VOCs were influenced by the type of sponge materials and mattress fabric layers. The study demonstrated that the method is sensitive, accurate and well-suited for the determination of VOCs emitted from mattresses. … (more)
- Is Part Of:
- International journal of environmental analytical chemistry. Volume 100:Issue 9(2020)
- Journal:
- International journal of environmental analytical chemistry
- Issue:
- Volume 100:Issue 9(2020)
- Issue Display:
- Volume 100, Issue 9 (2020)
- Year:
- 2020
- Volume:
- 100
- Issue:
- 9
- Issue Sort Value:
- 2020-0100-0009-0000
- Page Start:
- 1044
- Page End:
- 1065
- Publication Date:
- 2020-07-14
- Subjects:
- Environment test chamber -- thermal desorption -- gas chromatography-mass spectrometry -- volatile organic compounds -- mattress
Ecology -- Periodicals
Chemistry, Analytic -- Periodicals
Environmental chemistry -- Periodicals
Pollution -- Periodicals
577.14 - Journal URLs:
- http://www.tandfonline.com/toc/geac20/current ↗
http://www.tandfonline.com/ ↗ - DOI:
- 10.1080/03067319.2019.1647187 ↗
- Languages:
- English
- ISSNs:
- 0306-7319
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4542.241000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 22950.xml