Comparison of iridocorneal angle parameters measured by spectral domain optical coherence tomography and ultrasound biomicroscopy in dogs. (16th November 2021)
- Record Type:
- Journal Article
- Title:
- Comparison of iridocorneal angle parameters measured by spectral domain optical coherence tomography and ultrasound biomicroscopy in dogs. (16th November 2021)
- Main Title:
- Comparison of iridocorneal angle parameters measured by spectral domain optical coherence tomography and ultrasound biomicroscopy in dogs
- Authors:
- Shim, Jaeho
Kang, Seonmi
Jeong, Youngseok
Lee, Eunji
Jeong, Dajeong
Seo, Kangmoon - Abstract:
- Abstract: Objective: To compare the measurements of iridocorneal angle parameters between spectral domain optical coherence tomography (SD‐OCT) and ultrasound biomicroscopy (UBM) in dogs. Animals studied and procedures: A total of 47 eyes of dogs were scanned at the temporal limbus using SD‐OCT and UBM. Iridocorneal angle (ICA) and angle opening distance (AOD) were measured from the obtained images accordingly. The intra‐observer and inter‐observer reproducibility were evaluated using the intraclass correlation coefficient. To evaluate intra‐observer reproducibility, measurements of the first and second grading from the first examiner were compared. To evaluate inter‐observer reproducibility, measurements between the two examiners were compared. Agreement between ICA and AOD for SD‐OCT and UBM was evaluated using Bland‐Altman plots. Results: In the first grading, the mean ICA and AOD for SD‐OCT were 31.4 ± 6.4° and 641.4 ± 270.8 µm, respectively. The mean ICA and AOD for UBM were 32.0 ± 4.8° and 700.4 ± 238.8 µm, respectively. For ICA and AOD measurements, intra‐observer reproducibility was excellent for both devices, whereas inter‐observer reproducibility was excellent for SD‐OCT and good for UBM. The mean difference in ICA between SD‐OCT and UBM was 0.6° with a limit of agreement (LoA) span of 18.9°. The mean difference in AOD between SD‐OCT and UBM was 58.9 µm with a LoA span of 804.4 µm. Conclusions: Spectral domain optical coherence tomography is an effectiveAbstract: Objective: To compare the measurements of iridocorneal angle parameters between spectral domain optical coherence tomography (SD‐OCT) and ultrasound biomicroscopy (UBM) in dogs. Animals studied and procedures: A total of 47 eyes of dogs were scanned at the temporal limbus using SD‐OCT and UBM. Iridocorneal angle (ICA) and angle opening distance (AOD) were measured from the obtained images accordingly. The intra‐observer and inter‐observer reproducibility were evaluated using the intraclass correlation coefficient. To evaluate intra‐observer reproducibility, measurements of the first and second grading from the first examiner were compared. To evaluate inter‐observer reproducibility, measurements between the two examiners were compared. Agreement between ICA and AOD for SD‐OCT and UBM was evaluated using Bland‐Altman plots. Results: In the first grading, the mean ICA and AOD for SD‐OCT were 31.4 ± 6.4° and 641.4 ± 270.8 µm, respectively. The mean ICA and AOD for UBM were 32.0 ± 4.8° and 700.4 ± 238.8 µm, respectively. For ICA and AOD measurements, intra‐observer reproducibility was excellent for both devices, whereas inter‐observer reproducibility was excellent for SD‐OCT and good for UBM. The mean difference in ICA between SD‐OCT and UBM was 0.6° with a limit of agreement (LoA) span of 18.9°. The mean difference in AOD between SD‐OCT and UBM was 58.9 µm with a LoA span of 804.4 µm. Conclusions: Spectral domain optical coherence tomography is an effective non‐contact imaging modality for the evaluation of canine iridocorneal angle parameters in a clinical setting. Reproducibility of measurements obtained is comparable or superior to UBM, but values obtained by SD‐OCT and UBM for AOD are not interchangeable between devices. … (more)
- Is Part Of:
- Veterinary ophthalmology. Volume 25(2022)Supplement 1
- Journal:
- Veterinary ophthalmology
- Issue:
- Volume 25(2022)Supplement 1
- Issue Display:
- Volume 25, Issue 1 (2022)
- Year:
- 2022
- Volume:
- 25
- Issue:
- 1
- Issue Sort Value:
- 2022-0025-0001-0000
- Page Start:
- 103
- Page End:
- 110
- Publication Date:
- 2021-11-16
- Subjects:
- angle opening distance -- dogs -- iridocorneal angle -- iridocorneal angle parameters -- spectral domain optical coherence tomography -- ultrasound biomicroscopy
Veterinary ophthalmology -- Periodicals
636.08977 - Journal URLs:
- http://www.blackwell-synergy.com/member/institutions/issuelist.asp?journal=vop ↗
http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1463-5224 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1111/vop.12950 ↗
- Languages:
- English
- ISSNs:
- 1463-5216
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 9229.162000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 22938.xml