Surgical aortic valve replacement with a stented pericardial bioprosthesis: 5-year outcomes. (5th July 2022)
- Record Type:
- Journal Article
- Title:
- Surgical aortic valve replacement with a stented pericardial bioprosthesis: 5-year outcomes. (5th July 2022)
- Main Title:
- Surgical aortic valve replacement with a stented pericardial bioprosthesis: 5-year outcomes
- Authors:
- Klautz, Robert J M
Dagenais, François
Reardon, Michael J
Lange, Rüdiger
Moront, Michael G
Labrousse, Louis
Weissman, Neil J
Rao, Vivek
Patel, Himanshu J
Liu, Fang
Sabik, Joseph F - Abstract:
- Abstract: OBJECTIVES: This analysis evaluated the safety, durability and haemodynamic performance of a stented bovine pericardial valve through 5 years of follow-up in patients with an indication for surgical aortic valve replacement. METHODS: Kaplan–Meier analysis was used to estimate the incidence of survival and valve-related thromboembolism, major paravalvular leak, endocarditis, structural valve deterioration (SVD) and reintervention. The mean aortic gradient and New York Heart Association (NYHA) functional class were also evaluated. RESULTS: A total of 1118 patients have received the Avalus valve; 564 have completed the 5-year follow-up. The median follow-up was 4.85 years (4810 patient-years total follow-up). At baseline, the mean age was 70.2 ± 9.0 years; 75.1% of patients were male. The Society of Thoracic Surgeons predicted risk of mortality was 2.0 ± 1.4%. Most patients were in NYHA functional class II (46.8%) or III (40.3%). At the 5-year follow-up, the overall Kaplan–Meier survival rate was 88.1% (85.9–90.0%). The Kaplan–Meier event rates were 5.6% (4.3–7.2%) for thromboembolism, 4.4% (3.2–6.0%) for endocarditis, 0.2% (0.0–0.7%) for a major paravalvular leak and 3.2% (2.3–4.6%) for reintervention. There were no cases of SVD. The mean gradient decreased from 42.1 ± 17.1 mmHg at baseline, to 13.1 ± 4.7 mmHg at discharge and remained stable at 12.5 ± 4.6 mmHg at 5 years. More than 95% of patients were in NYHA functional class I/II 5 years after surgery.Abstract: OBJECTIVES: This analysis evaluated the safety, durability and haemodynamic performance of a stented bovine pericardial valve through 5 years of follow-up in patients with an indication for surgical aortic valve replacement. METHODS: Kaplan–Meier analysis was used to estimate the incidence of survival and valve-related thromboembolism, major paravalvular leak, endocarditis, structural valve deterioration (SVD) and reintervention. The mean aortic gradient and New York Heart Association (NYHA) functional class were also evaluated. RESULTS: A total of 1118 patients have received the Avalus valve; 564 have completed the 5-year follow-up. The median follow-up was 4.85 years (4810 patient-years total follow-up). At baseline, the mean age was 70.2 ± 9.0 years; 75.1% of patients were male. The Society of Thoracic Surgeons predicted risk of mortality was 2.0 ± 1.4%. Most patients were in NYHA functional class II (46.8%) or III (40.3%). At the 5-year follow-up, the overall Kaplan–Meier survival rate was 88.1% (85.9–90.0%). The Kaplan–Meier event rates were 5.6% (4.3–7.2%) for thromboembolism, 4.4% (3.2–6.0%) for endocarditis, 0.2% (0.0–0.7%) for a major paravalvular leak and 3.2% (2.3–4.6%) for reintervention. There were no cases of SVD. The mean gradient decreased from 42.1 ± 17.1 mmHg at baseline, to 13.1 ± 4.7 mmHg at discharge and remained stable at 12.5 ± 4.6 mmHg at 5 years. More than 95% of patients were in NYHA functional class I/II 5 years after surgery. CONCLUSIONS: The findings of a high survival rate, excellent safety, no SVD and stable haemodynamic performance and functional status through 5 years of follow-up are encouraging. Additional follow-up is needed to assess the long-term durability of this contemporary surgical bioprosthesis. Abstract : Surgical aortic valve replacement (SAVR) is one of the most frequently performed cardiac operations. … (more)
- Is Part Of:
- European journal of cardio-thoracic surgery. Volume 62:Number 3(2022)
- Journal:
- European journal of cardio-thoracic surgery
- Issue:
- Volume 62:Number 3(2022)
- Issue Display:
- Volume 62, Issue 3 (2022)
- Year:
- 2022
- Volume:
- 62
- Issue:
- 3
- Issue Sort Value:
- 2022-0062-0003-0000
- Page Start:
- Page End:
- Publication Date:
- 2022-07-05
- Subjects:
- Cardiac surgery -- Aortic valve disease -- Surgical aortic valve replacement -- Bovine pericardial aortic bioprosthesis
Heart -- Surgery -- Periodicals
Chest -- Surgery -- Periodicals
617.54 - Journal URLs:
- http://ejcts.oxfordjournals.org/ ↗
http://www.sciencedirect.com/science/journal/10107940 ↗
http://ukcatalogue.oup.com/ ↗ - DOI:
- 10.1093/ejcts/ezac374 ↗
- Languages:
- English
- ISSNs:
- 1010-7940
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3829.725620
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 22899.xml