Ex vivo evaluation of the Ozaki procedure in comparison with the native aortic valve and prosthetic valves. (27th July 2022)
- Record Type:
- Journal Article
- Title:
- Ex vivo evaluation of the Ozaki procedure in comparison with the native aortic valve and prosthetic valves. (27th July 2022)
- Main Title:
- Ex vivo evaluation of the Ozaki procedure in comparison with the native aortic valve and prosthetic valves
- Authors:
- Saisho, Hiroyuki
Scharfschwerdt, Michael
Schaller, Tim
Sadat, Najla
Aboud, Anas
Ensminger, Stephan
Fujita, Buntaro - Abstract:
- Abstract: OBJECTIVES: We investigated the hydrodynamic performance and cusp kinematics of the Ozaki neocuspidized aortic valve in comparison with the native aortic and prosthetic valves in an ex vivo study. METHODS: Native aortic valves of swine hearts were replaced by aortic valve substitutes, and their hydrodynamic performance (effective orifice area and mean pressure gradient) was evaluated in a mock circulation under defined conditions. The following aortic valve substitutes were investigated: native aortic valve, Ozaki valve, Perimount Magna Ease, Trifecta and St. Jude Medical Masters. All prosthetic valves had a labelled size of 21 mm. RESULTS: The Ozaki valve and native aortic valve showed a similar and significantly larger orifice area than all investigated prosthetic valves particularly at high flow rates. There was no significant difference between the Ozaki valve and the native aortic valve. The native aortic valve and Ozaki valve showed a similar increase in orifice area with increasing flow through the valve while prosthetic valves showed a markedly weaker increase. Similarly, the native and Ozaki valve showed a similar increase in mPG with forward flow which was weaker than prosthetic valves. Cusp kinematics were similar between the native and Ozaki valve, whilst prosthetic valves were clearly distinguishable from them. CONCLUSIONS: The Ozaki procedure showed excellent hydrodynamic performance compared to prosthetic valves and showed similar cusp motionAbstract: OBJECTIVES: We investigated the hydrodynamic performance and cusp kinematics of the Ozaki neocuspidized aortic valve in comparison with the native aortic and prosthetic valves in an ex vivo study. METHODS: Native aortic valves of swine hearts were replaced by aortic valve substitutes, and their hydrodynamic performance (effective orifice area and mean pressure gradient) was evaluated in a mock circulation under defined conditions. The following aortic valve substitutes were investigated: native aortic valve, Ozaki valve, Perimount Magna Ease, Trifecta and St. Jude Medical Masters. All prosthetic valves had a labelled size of 21 mm. RESULTS: The Ozaki valve and native aortic valve showed a similar and significantly larger orifice area than all investigated prosthetic valves particularly at high flow rates. There was no significant difference between the Ozaki valve and the native aortic valve. The native aortic valve and Ozaki valve showed a similar increase in orifice area with increasing flow through the valve while prosthetic valves showed a markedly weaker increase. Similarly, the native and Ozaki valve showed a similar increase in mPG with forward flow which was weaker than prosthetic valves. Cusp kinematics were similar between the native and Ozaki valve, whilst prosthetic valves were clearly distinguishable from them. CONCLUSIONS: The Ozaki procedure showed excellent hydrodynamic performance compared to prosthetic valves and showed similar cusp motion characteristics to the native aortic valve. Our results suggest that the Ozaki neocuspidized valve behaves physiologically in many aspects, which may contribute to beneficial clinical outcomes. Abstract : Treatment of aortic stenosis (AS) in non-elderly patients poses a tremendous clinical challenge. … (more)
- Is Part Of:
- Interactive cardiovascular and thoracic surgery. Volume 35:Number 3(2022)
- Journal:
- Interactive cardiovascular and thoracic surgery
- Issue:
- Volume 35:Number 3(2022)
- Issue Display:
- Volume 35, Issue 3 (2022)
- Year:
- 2022
- Volume:
- 35
- Issue:
- 3
- Issue Sort Value:
- 2022-0035-0003-0000
- Page Start:
- Page End:
- Publication Date:
- 2022-07-27
- Subjects:
- Ozaki procedure -- Aortic valve replacement -- Ex vivo -- Valve motion -- Hydrodynamic performance
Chest -- Surgery -- Periodicals
Cardiovascular system -- Diseases -- Periodicals
616.1 - Journal URLs:
- http://icvts.oxfordjournals.org/ ↗
http://ukcatalogue.oup.com/ ↗ - DOI:
- 10.1093/icvts/ivac199 ↗
- Languages:
- English
- ISSNs:
- 1569-9293
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4531.871920
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 22910.xml