Energy Dose-Response in Selective Laser Trabeculoplasty: A Review. Issue 8 (15th August 2022)
- Record Type:
- Journal Article
- Title:
- Energy Dose-Response in Selective Laser Trabeculoplasty: A Review. Issue 8 (15th August 2022)
- Main Title:
- Energy Dose-Response in Selective Laser Trabeculoplasty: A Review
- Authors:
- Radcliffe, Nathan
Gazzard, Gus
Samuelson, Thomas
Khaw, Peng
Sun, Xinghuai
Aung, Tin
Lam, Dennis
Singh, Kuldev
Katz, L. Jay
Aronov, Michael
Sacks, Zachary
Solberg, Yoram
Lindstrom, Richard
Belkin, Michael - Abstract:
- Abstract : Précis: A literature review of selective laser trabeculoplasty (SLT) energy dose-response found no definitive relationship between intraocular pressure (IOP) reduction with respect to total or pulse energy, race, pigmentation, or application pattern. Purpose: SLT is a safe and effective treatment for lowering IOP. Although evidence is mounting for the advantage of its use as a first-line treatment for IOP reduction, the SLT procedures in use vary widely. The purpose of this literature review was to investigate whether there were any relationships between SLT energy and efficacy for lowering IOP in the published literature. Methods: A literature review was undertaken that included studies in which energy levels required for successful SLT treatment were investigated: in general, with respect to angle pigmentation, race or ethnicity, and treatment arc extent. Results: There was no indication that higher (or lower) energy used in the treatment leads to greater (or less) IOP reduction. Similar results were obtained regarding the level of trabecular meshwork pigmentation. Race was not found to be associated with altered dose response in SLT. There were indications that treating the full 360 degrees, as opposed to smaller arcs, could be beneficial for more IOP reduction. IOP reduction from SLT was found to be similar to that provided by topical medications. Conclusions: The optimal energy level of SLT needed for IOP reduction has not yet been definitively established,Abstract : Précis: A literature review of selective laser trabeculoplasty (SLT) energy dose-response found no definitive relationship between intraocular pressure (IOP) reduction with respect to total or pulse energy, race, pigmentation, or application pattern. Purpose: SLT is a safe and effective treatment for lowering IOP. Although evidence is mounting for the advantage of its use as a first-line treatment for IOP reduction, the SLT procedures in use vary widely. The purpose of this literature review was to investigate whether there were any relationships between SLT energy and efficacy for lowering IOP in the published literature. Methods: A literature review was undertaken that included studies in which energy levels required for successful SLT treatment were investigated: in general, with respect to angle pigmentation, race or ethnicity, and treatment arc extent. Results: There was no indication that higher (or lower) energy used in the treatment leads to greater (or less) IOP reduction. Similar results were obtained regarding the level of trabecular meshwork pigmentation. Race was not found to be associated with altered dose response in SLT. There were indications that treating the full 360 degrees, as opposed to smaller arcs, could be beneficial for more IOP reduction. IOP reduction from SLT was found to be similar to that provided by topical medications. Conclusions: The optimal energy level of SLT needed for IOP reduction has not yet been definitively established, with all reported pulse energies resulting in similar IOP reduction. Furthermore, similar lack of conclusive findings exists regarding optimal SLT energy dosage for use in different races and degrees of trabecular meshwork pigmentation. This parameter and each of the abovementioned factors requires further research. … (more)
- Is Part Of:
- Journal of glaucoma. Volume 31:Issue 8(2022)
- Journal:
- Journal of glaucoma
- Issue:
- Volume 31:Issue 8(2022)
- Issue Display:
- Volume 31, Issue 8 (2022)
- Year:
- 2022
- Volume:
- 31
- Issue:
- 8
- Issue Sort Value:
- 2022-0031-0008-0000
- Page Start:
- e49
- Page End:
- e68
- Publication Date:
- 2022-08-15
- Subjects:
- selective laser trabeculoplasty -- energy dose-response -- glaucoma -- trabecular meshwork pigmentation -- ethnicity
Glaucoma -- Periodicals
617.741005 - Journal URLs:
- http://ovidsp.ovid.com/ovidweb.cgi?T=JS&NEWS=n&CSC=Y&PAGE=toc&D=yrovft&AN=00061198-000000000-00000 ↗
http://www.glaucomajournal.com ↗
http://journals.lww.com/glaucomajournal/pages/default.aspx ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/IJG.0000000000002062 ↗
- Languages:
- English
- ISSNs:
- 1057-0829
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4996.230000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 22903.xml