Assessing the Sensitivity of Dual-Energy Computed Tomography 3-Material Decomposition for the Detection of Gout. Issue 9 (21st September 2022)
- Record Type:
- Journal Article
- Title:
- Assessing the Sensitivity of Dual-Energy Computed Tomography 3-Material Decomposition for the Detection of Gout. Issue 9 (21st September 2022)
- Main Title:
- Assessing the Sensitivity of Dual-Energy Computed Tomography 3-Material Decomposition for the Detection of Gout
- Authors:
- Tse, Justin J.
Kondro, Douglas A.
Kuczynski, Michael T.
Pauchard, Yves
Veljkovic, Andrea
Holdsworth, David W.
Frasson, Viviane
Manske, Sarah L.
MacMullan, Paul
Salat, Peter - Abstract:
- Abstract : Objectives: The aim of this study was to assess the accuracy and precision of a novel application of 3-material decomposition (3MD) with virtual monochromatic images (VMIs) in the dual-energy computed tomography (DECT) assessment of monosodium urate (MSU) and hydroxyapatite (HA) phantoms compared with a commercial 2-material decomposition (2MD) and dual-thresholding (DT) material decomposition methods. Materials and Methods: Monosodium urate (0.0, 3.4, 13.3, 28.3, and 65.2 mg/dL tubes) and HA (100, 400, and 800 mg/cm 3 tubes) phantoms were DECT scanned individually and together in the presence of the foot and ankle of 15 subjects. The raw data were decomposed with 3MD-VMI, 2MD, and DT to produce MSU-only and HA-only images. Mean values of 10 × 10 × 10–voxel volumes of interest (244 μm 3 ) placed in each MSU and HA phantom well were obtained and compared with their known concentrations and across measurements with subjects' extremities to obtain accuracy and precision measures. A statistical difference was considered significant if P < 0.05. Results: Compared with known phantom standards, 3MD-VMI was accurate for the detection of MSU concentrations as low as 3.4 mg/dL ( P = 0.75). In comparison, 2MD was limited to 13.3 mg/dL ( P = 0.06) and DT was unable to detect MSU concentrations below 65.2 mg/L ( P = 0.16). For the HA phantom, 3MD-VMI and 2MD were accurate for all concentrations including the lowest at 100 mg/cm 3 ( P = 0.63 and P = 0.55, respectively).Abstract : Objectives: The aim of this study was to assess the accuracy and precision of a novel application of 3-material decomposition (3MD) with virtual monochromatic images (VMIs) in the dual-energy computed tomography (DECT) assessment of monosodium urate (MSU) and hydroxyapatite (HA) phantoms compared with a commercial 2-material decomposition (2MD) and dual-thresholding (DT) material decomposition methods. Materials and Methods: Monosodium urate (0.0, 3.4, 13.3, 28.3, and 65.2 mg/dL tubes) and HA (100, 400, and 800 mg/cm 3 tubes) phantoms were DECT scanned individually and together in the presence of the foot and ankle of 15 subjects. The raw data were decomposed with 3MD-VMI, 2MD, and DT to produce MSU-only and HA-only images. Mean values of 10 × 10 × 10–voxel volumes of interest (244 μm 3 ) placed in each MSU and HA phantom well were obtained and compared with their known concentrations and across measurements with subjects' extremities to obtain accuracy and precision measures. A statistical difference was considered significant if P < 0.05. Results: Compared with known phantom standards, 3MD-VMI was accurate for the detection of MSU concentrations as low as 3.4 mg/dL ( P = 0.75). In comparison, 2MD was limited to 13.3 mg/dL ( P = 0.06) and DT was unable to detect MSU concentrations below 65.2 mg/L ( P = 0.16). For the HA phantom, 3MD-VMI and 2MD were accurate for all concentrations including the lowest at 100 mg/cm 3 ( P = 0.63 and P = 0.55, respectively). Dual-thresholding was not useful for the decomposition of HA phantom. Precision was high for both 3MD-VMI and 2MD measurements for both MSU and HA phantoms. Qualitatively, 3MD-VMI MSU-only images demonstrated reduced beam-hardening artifact and voxel misclassification, compared with 2MD and DT. Conclusions: Three-material decomposition-VMI DECT is accurate for quantification of MSU and HA concentrations in phantoms and accurately detects a lower concentration of MSU than either 2MD or DT. For concentration measurements of both MSU and HA phantoms, 3MD-VMI and 2MD have high precision, but DT had limitations. Clinical implementation of 3MD-VMI DECT promises to improve the performance of this imaging modality for diagnosis and treatment monitoring of gout. … (more)
- Is Part Of:
- Investigative radiology. Volume 57:Issue 9(2022)
- Journal:
- Investigative radiology
- Issue:
- Volume 57:Issue 9(2022)
- Issue Display:
- Volume 57, Issue 9 (2022)
- Year:
- 2022
- Volume:
- 57
- Issue:
- 9
- Issue Sort Value:
- 2022-0057-0009-0000
- Page Start:
- 613
- Page End:
- 619
- Publication Date:
- 2022-09-21
- Subjects:
- dual-energy computed tomography -- gout -- monosodium urate -- 3-material decomposition -- virtual monochromatic images -- dual-thresholding
Diagnosis, Radioscopic -- Periodicals
Radiology, Medical -- Periodicals
616.0757 - Journal URLs:
- http://journals.lww.com/investigativeradiology/pages/default.aspx ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/RLI.0000000000000879 ↗
- Languages:
- English
- ISSNs:
- 0020-9996
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4560.350000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 22903.xml