T1‐corrected quantitative chemical shift‐encoded MRI. Issue 6 (14th November 2019)
- Record Type:
- Journal Article
- Title:
- T1‐corrected quantitative chemical shift‐encoded MRI. Issue 6 (14th November 2019)
- Main Title:
- T1‐corrected quantitative chemical shift‐encoded MRI
- Authors:
- Wang, Xiaoke
Colgan, Timothy J.
Hinshaw, Louis A.
Roberts, Nathan T.
Bancroft, Leah C. Henze
Hamilton, Gavin
Hernando, Diego
Reeder, Scott B. - Abstract:
- Abstract : Purpose: To develop and validate a T1 ‐corrected chemical‐shift encoded MRI (CSE‐MRI) method to improve noise performance and reduce bias for quantification of tissue proton density fat‐fraction (PDFF). Methods: A variable flip angle (VFA)‐CSE‐MRI method using joint‐fit reconstruction was developed and implemented. In computer simulations and phantom experiments, sources of bias measured using VFA‐CSE‐MRI were investigated. The effect of tissue T1 on bias using low flip angle (LFA)‐CSE‐MRI was also evaluated. The noise performance of VFA‐CSE‐MRI was compared to LFA‐CSE‐MRI for liver fat quantification. Finally, a prospective pilot study in patients undergoing gadoxetic acid‐enhanced MRI of the liver to evaluate the ability of the proposed method to quantify liver PDFF before and after contrast. Results: VFA‐CSE‐MRI was accurate and insensitive to transmit B1 inhomogeneities in phantom experiments and computer simulations. With high flip angles, phase errors because of RF spoiling required modification of the CSE signal model. For relaxation parameters commonly observed in liver, the joint‐fit reconstruction improved the noise performance marginally, compared to LFA‐CSE‐MRI, but eliminated T1 ‐related bias. A total of 25 patients were successfully recruited and analyzed for the pilot study. Strong correlation and good agreement between PDFF measured with VFA‐CSE‐MRI and LFA‐CSE‐MRI (pre‐contrast) was observed before (R 2 = 0.97; slope = 0.88, 0.81–0.94 95%Abstract : Purpose: To develop and validate a T1 ‐corrected chemical‐shift encoded MRI (CSE‐MRI) method to improve noise performance and reduce bias for quantification of tissue proton density fat‐fraction (PDFF). Methods: A variable flip angle (VFA)‐CSE‐MRI method using joint‐fit reconstruction was developed and implemented. In computer simulations and phantom experiments, sources of bias measured using VFA‐CSE‐MRI were investigated. The effect of tissue T1 on bias using low flip angle (LFA)‐CSE‐MRI was also evaluated. The noise performance of VFA‐CSE‐MRI was compared to LFA‐CSE‐MRI for liver fat quantification. Finally, a prospective pilot study in patients undergoing gadoxetic acid‐enhanced MRI of the liver to evaluate the ability of the proposed method to quantify liver PDFF before and after contrast. Results: VFA‐CSE‐MRI was accurate and insensitive to transmit B1 inhomogeneities in phantom experiments and computer simulations. With high flip angles, phase errors because of RF spoiling required modification of the CSE signal model. For relaxation parameters commonly observed in liver, the joint‐fit reconstruction improved the noise performance marginally, compared to LFA‐CSE‐MRI, but eliminated T1 ‐related bias. A total of 25 patients were successfully recruited and analyzed for the pilot study. Strong correlation and good agreement between PDFF measured with VFA‐CSE‐MRI and LFA‐CSE‐MRI (pre‐contrast) was observed before (R 2 = 0.97; slope = 0.88, 0.81–0.94 95% confidence interval [CI]; intercept = 1.34, −0.77–1.92 95% CI) and after (R 2 = 0.93; slope = 0.88, 0.78–0.98 95% CI; intercept = 1.90, 1.01–2.79 95% CI) contrast. Conclusion: Joint‐fit VFA‐CSE‐MRI is feasible for T1 ‐corrected PDFF quantification in liver, is insensitive to B1 inhomogeneities, and can eliminate T1 bias, but with only marginal SNR advantage for T1 values observed in the liver. … (more)
- Is Part Of:
- Magnetic resonance in medicine. Volume 83:Issue 6(2020)
- Journal:
- Magnetic resonance in medicine
- Issue:
- Volume 83:Issue 6(2020)
- Issue Display:
- Volume 83, Issue 6 (2020)
- Year:
- 2020
- Volume:
- 83
- Issue:
- 6
- Issue Sort Value:
- 2020-0083-0006-0000
- Page Start:
- 2051
- Page End:
- 2063
- Publication Date:
- 2019-11-14
- Subjects:
- chemical‐shift encoded imaging -- fat quantification -- hepatic steatosis -- liver fat -- magnetic resonance imaging -- proton density fat‐fraction -- T1 bias -- T1 correction
Nuclear magnetic resonance -- Periodicals
Electron paramagnetic resonance -- Periodicals
616.07548 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-2594 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/mrm.28062 ↗
- Languages:
- English
- ISSNs:
- 0740-3194
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5337.798000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 22899.xml