In vitro CT visualization of the biopsy location by filling the core biopsy needle with contrast media. (October 2022)
- Record Type:
- Journal Article
- Title:
- In vitro CT visualization of the biopsy location by filling the core biopsy needle with contrast media. (October 2022)
- Main Title:
- In vitro CT visualization of the biopsy location by filling the core biopsy needle with contrast media
- Authors:
- Thunswärd, Per
Eksell, David
Ahlström, Håkan
Magnusson, Anders - Abstract:
- Background: When performing computed tomography (CT)-guided biopsy procedures with non-disposable, automatic biopsy instruments, the actual course of the biopsy needle is not registered. Purpose: To evaluate the ability to visualize the sampling location after CT-guided biopsy in vitro using a novel method, where the space between the inner needle and the outer cannula in a core biopsy needle is filled with contrast media; and to compare the grade of visibility for two different concentrations of contrast media. Material and Methods: Core needle biopsies were performed in a tissue phantom using biopsy needles primed with two different iodine contrast media concentrations (140 mg I/mL and 400 mg I/mL). Commercially available needle-filling contraptions with sealing membranes were used to fill the needles. Each biopsy was imaged with CT, and the visibility was evaluated twice by three senior radiologists in a randomized order. Results: The presence of traces was confirmed after biopsy, almost without exception for both concentrations. The visibility was sufficient to determine the biopsy location in all observations with the 400 mg I/mL filling, and in 7/10 observations with the 140 mg I/mL filling. The grade of visibility of the trace and the proportion of the biopsy needle course outlined were higher with the 400 mg I/mL filling. Conclusion: With CT-guided biopsy in vitro, the sampling location can be visualized using a novel method of priming the biopsy needle with iodineBackground: When performing computed tomography (CT)-guided biopsy procedures with non-disposable, automatic biopsy instruments, the actual course of the biopsy needle is not registered. Purpose: To evaluate the ability to visualize the sampling location after CT-guided biopsy in vitro using a novel method, where the space between the inner needle and the outer cannula in a core biopsy needle is filled with contrast media; and to compare the grade of visibility for two different concentrations of contrast media. Material and Methods: Core needle biopsies were performed in a tissue phantom using biopsy needles primed with two different iodine contrast media concentrations (140 mg I/mL and 400 mg I/mL). Commercially available needle-filling contraptions with sealing membranes were used to fill the needles. Each biopsy was imaged with CT, and the visibility was evaluated twice by three senior radiologists in a randomized order. Results: The presence of traces was confirmed after biopsy, almost without exception for both concentrations. The visibility was sufficient to determine the biopsy location in all observations with the 400 mg I/mL filling, and in 7/10 observations with the 140 mg I/mL filling. The grade of visibility of the trace and the proportion of the biopsy needle course outlined were higher with the 400 mg I/mL filling. Conclusion: With CT-guided biopsy in vitro, the sampling location can be visualized using a novel method of priming the biopsy needle with iodine contrast media, specifically highly concentrated contrast media. … (more)
- Is Part Of:
- Acta radiologica. Volume 63:Number 10(2022)
- Journal:
- Acta radiologica
- Issue:
- Volume 63:Number 10(2022)
- Issue Display:
- Volume 63, Issue 10 (2022)
- Year:
- 2022
- Volume:
- 63
- Issue:
- 10
- Issue Sort Value:
- 2022-0063-0010-0000
- Page Start:
- 1406
- Page End:
- 1414
- Publication Date:
- 2022-10
- Subjects:
- CT -- Biopsy -- Contrast Agents-Other -- Experimental Investigations
Radiology, Medical -- Periodicals
Radiography, Medical -- Periodicals
Radiotherapy -- Periodicals
616.0757 - Journal URLs:
- http://acr.sagepub.com ↗
http://ar.rsmjournals.com ↗
http://www.uk.sagepub.com/home.nav ↗
http://informahealthcare.com/loi/ard ↗
http://www.tandf.co.uk/journals/titles/02841851.asp ↗ - DOI:
- 10.1177/02841851211041831 ↗
- Languages:
- English
- ISSNs:
- 0284-1851
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 0662.000000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 22878.xml