BLADE turbo gradient- and spin-echo in the assessment of sinonasal lesions: a comprehensive comparison of image quality in readout-segmented echo-planar imaging. (October 2022)
- Record Type:
- Journal Article
- Title:
- BLADE turbo gradient- and spin-echo in the assessment of sinonasal lesions: a comprehensive comparison of image quality in readout-segmented echo-planar imaging. (October 2022)
- Main Title:
- BLADE turbo gradient- and spin-echo in the assessment of sinonasal lesions: a comprehensive comparison of image quality in readout-segmented echo-planar imaging
- Authors:
- Geng, Yue
Shi, Yiqian
Chen, Wei
Tang, Zuohua
Zhang, Zhongshuai
Zhou, Kun
Sha, Yan - Abstract:
- Background: A two-dimensional turbo gradient-echo and spin-echo diffusion-weighted pulse sequence with a non-Cartesian BLADE trajectory (TGSE BLADE) can eliminate image artifacts and distortion with clinically acceptable scan times. This process has the potential to overcome the shortcomings of current diffusion-weighted imaging (DWI) techniques, especially in the sinonasal region. Purpose: To investigate the feasibility of TGSE BLADE in the assessment of sinonasal lesions and compare the quality of TGSE BLADE with RESOLVE images both qualitatively and quantitatively. Material and Methods: A total of 36 patients with sinonasal lesions were included in this prospective study. DW images acquired using TGSE BLADE and RESOLVE were performed with the same acquisition time. Two independent observers evaluated the qualitative parameters (overall image quality, lesion visibility, and geometric distortion) and quantitative parameters (geometric distortion ratio [GDR], signal-to-noise ratio [SNR], contrast, contrast-to-noise ratio [CNR], and apparent diffusion coefficient [ADC] value) of the two sequences. Results: Qualitative assessment revealed that TGSE BLADE exhibited higher overall image quality ( P < 0.001) and lesion visibility ( P < 0.001) and less geometric distortion ( P < 0.001) than RESOLVE. Quantitative assessment showed that TGSE BLADE images exhibited higher contrast ( P < 0.001) and CNR ( P < 0.001) and lower GDR ( P < 0.05) and SNR ( P < 0.001) than RESOLVEBackground: A two-dimensional turbo gradient-echo and spin-echo diffusion-weighted pulse sequence with a non-Cartesian BLADE trajectory (TGSE BLADE) can eliminate image artifacts and distortion with clinically acceptable scan times. This process has the potential to overcome the shortcomings of current diffusion-weighted imaging (DWI) techniques, especially in the sinonasal region. Purpose: To investigate the feasibility of TGSE BLADE in the assessment of sinonasal lesions and compare the quality of TGSE BLADE with RESOLVE images both qualitatively and quantitatively. Material and Methods: A total of 36 patients with sinonasal lesions were included in this prospective study. DW images acquired using TGSE BLADE and RESOLVE were performed with the same acquisition time. Two independent observers evaluated the qualitative parameters (overall image quality, lesion visibility, and geometric distortion) and quantitative parameters (geometric distortion ratio [GDR], signal-to-noise ratio [SNR], contrast, contrast-to-noise ratio [CNR], and apparent diffusion coefficient [ADC] value) of the two sequences. Results: Qualitative assessment revealed that TGSE BLADE exhibited higher overall image quality ( P < 0.001) and lesion visibility ( P < 0.001) and less geometric distortion ( P < 0.001) than RESOLVE. Quantitative assessment showed that TGSE BLADE images exhibited higher contrast ( P < 0.001) and CNR ( P < 0.001) and lower GDR ( P < 0.05) and SNR ( P < 0.001) than RESOLVE images. The ADC value of TGSE BLADE was significantly lower than that of RESOLVE ( P < 0.05). Conclusion: TGSE BLADE can reduce susceptibility artifacts and geometric distortion more than RESOLVE and appears to be a promising diffusion imaging sequence for the assessment of sinonasal lesions. … (more)
- Is Part Of:
- Acta radiologica. Volume 63:Number 10(2022)
- Journal:
- Acta radiologica
- Issue:
- Volume 63:Number 10(2022)
- Issue Display:
- Volume 63, Issue 10 (2022)
- Year:
- 2022
- Volume:
- 63
- Issue:
- 10
- Issue Sort Value:
- 2022-0063-0010-0000
- Page Start:
- 1381
- Page End:
- 1389
- Publication Date:
- 2022-10
- Subjects:
- Magnetic resonance imaging -- diffusion-weighted imaging -- nose
Radiology, Medical -- Periodicals
Radiography, Medical -- Periodicals
Radiotherapy -- Periodicals
616.0757 - Journal URLs:
- http://acr.sagepub.com ↗
http://ar.rsmjournals.com ↗
http://www.uk.sagepub.com/home.nav ↗
http://informahealthcare.com/loi/ard ↗
http://www.tandf.co.uk/journals/titles/02841851.asp ↗ - DOI:
- 10.1177/02841851211041820 ↗
- Languages:
- English
- ISSNs:
- 0284-1851
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 0662.000000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 22878.xml