Quantifying the bone marrow composition of the healthy adult wrist with dual-energy CT. Issue 139 (June 2021)
- Record Type:
- Journal Article
- Title:
- Quantifying the bone marrow composition of the healthy adult wrist with dual-energy CT. Issue 139 (June 2021)
- Main Title:
- Quantifying the bone marrow composition of the healthy adult wrist with dual-energy CT
- Authors:
- Müller, Felix C.
Gosvig, Kasper K.
Mikkel, Østergaard
Bjarne, Roed
Rodell, Anders
Henrik, Børgesen
Krauss, Bernhard
Gade, Jesper S.
Boesen, Mikael - Abstract:
- Highlights: Absolute quantification of bone marrow in the wrist is possible with Dual-Energy CT. Material decomposition parameters for VNCa images should be adjusted. Sex, age and calcium values have a clinically negligible effect on VNCa values. Abstract: Purpose: Purpose of this study was to investigate Dual-energy CT (DECT) derived virtual non-calcium (VNCa) values for absolute quantification of the bone marrow composition in the wrist. Materials and Methods: We prospectively included consecutive adult participants and examined their wrists with DECT. Ranges of VNCa and calcium values were measured in the carpal bones, radius and ulna using a semi-automatic method. Bones with bone marrow edema, assessed by two blinded radiologists, were excluded. After determining optimum parameters for the three-material decomposition, the influence of calcium values, age and sex on VNCa values was assessed using multiple linear regression. Results: 41 participants (Median age 53 years, range 20 years – 88 years, 51 % men) were enrolled and 399 bones assessed. At participant level mean VNCa values were -143 HU (SD 14 HU) using the current parameters for three-material decomposition and -104HU (SD 11 HU) with optimized parameters. There was a strong and significant influence of calcium values on VNCa values with the current parameters (p < 0.001, -0.137 HU[VNCa] / HU[Calcium] ). With optimized parameters the calcium values and sex were not statistically significant predictors of VNCaHighlights: Absolute quantification of bone marrow in the wrist is possible with Dual-Energy CT. Material decomposition parameters for VNCa images should be adjusted. Sex, age and calcium values have a clinically negligible effect on VNCa values. Abstract: Purpose: Purpose of this study was to investigate Dual-energy CT (DECT) derived virtual non-calcium (VNCa) values for absolute quantification of the bone marrow composition in the wrist. Materials and Methods: We prospectively included consecutive adult participants and examined their wrists with DECT. Ranges of VNCa and calcium values were measured in the carpal bones, radius and ulna using a semi-automatic method. Bones with bone marrow edema, assessed by two blinded radiologists, were excluded. After determining optimum parameters for the three-material decomposition, the influence of calcium values, age and sex on VNCa values was assessed using multiple linear regression. Results: 41 participants (Median age 53 years, range 20 years – 88 years, 51 % men) were enrolled and 399 bones assessed. At participant level mean VNCa values were -143 HU (SD 14 HU) using the current parameters for three-material decomposition and -104HU (SD 11 HU) with optimized parameters. There was a strong and significant influence of calcium values on VNCa values with the current parameters (p < 0.001, -0.137 HU[VNCa] / HU[Calcium] ). With optimized parameters the calcium values and sex were not statistically significant predictors of VNCa values. Age was a significant, but clinically negligible, predictor (p = 0.03, -0.225 HU / year). Conclusions: After optimizing three-material decomposition parameters, calcium values, age and sex do not substantially influence virtual non-calcium values, and DECT may therefore be used for absolute quantification of the bone marrow composition - alleviating the need for reference bones or groups. … (more)
- Is Part Of:
- European journal of radiology. Issue 139(2021)
- Journal:
- European journal of radiology
- Issue:
- Issue 139(2021)
- Issue Display:
- Volume 139, Issue 139 (2021)
- Year:
- 2021
- Volume:
- 139
- Issue:
- 139
- Issue Sort Value:
- 2021-0139-0139-0000
- Page Start:
- Page End:
- Publication Date:
- 2021-06
- Subjects:
- DECT Dual-energy CT -- VNCa Virtual non-calcium
Multidetector computed tomography -- Dual-energy computed tomography -- Bone marrow -- Bone marrow oedema -- Wrist -- Scaphoid
Medical radiology -- Periodicals
Radiology -- Periodicals
Radiologie médicale -- Périodiques
Medical radiology
Periodicals
616.075705 - Journal URLs:
- http://www.sciencedirect.com/science/journal/0720048X ↗
http://www.elsevier.com/homepage/elecserv.htt ↗
http://www.clinicalkey.com/dura/browse/journalIssue/0720048X ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/0720048X ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.ejrad.2021.109725 ↗
- Languages:
- English
- ISSNs:
- 0720-048X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3829.738050
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 22881.xml