Diagnostic value of diffusion-weighted STEAM-MRI in ischemic stroke. Issue 139 (June 2021)
- Record Type:
- Journal Article
- Title:
- Diagnostic value of diffusion-weighted STEAM-MRI in ischemic stroke. Issue 139 (June 2021)
- Main Title:
- Diagnostic value of diffusion-weighted STEAM-MRI in ischemic stroke
- Authors:
- Müller, Sebastian Johannes
Khadhraoui, Eya
Kube, Julia My Van
Langer, Philip
Riedel, Christian Heiner
Voit, Dirk
Ernst, Marielle
Frahm, Jens - Abstract:
- Abstract: Introduction: Diffusion-weighted imaging in stimulated echo acquisition mode (STEAM-DWI) is an interesting alternative with less susceptibility artifacts compared to the most commonly used diffusion-weighted echo-planar imaging (EPI-DWI). Sensitivity and specificity of a novel STEAM-DWI, described by Merrem et al. 2017 [1], were assessed in patients with ischemic stroke. Methods: EPI- and STEAM-DWIs were performed in patients with suspected subacute stroke between 01 July 2019 and 30 June 2020 using 3-T MRI. Three neuroradiologists independently and separately rated STEAM-DWI images with respect to (i) signs of an acute/subacute stroke, (ii) the number, size and localization of infarctions and, (iii) the presence of artifacts. Results: In 55 (23 right, 23 left, 9 both hemispheres) of 85 patients a subacute stroke was confirmed using EPI-DWI. The cerebral vascular territories were affected as follows: anterior cerebral artery 8 %, middle cerebral artery 48 %, posterior cerebral artery 27 %, brainstem 7 %, cerebellum 10 %. In 53 of 55 (96 %) cases the stroke was detected by usage of STEAM-DWI, in 35 of 37 patients microembolic events were noticed (95 %). Results showed a sensitivity and specificity of 100 % (70/70) for major infarcts (>9 mm² in-plane) and a sensitivity of up to 94 % (121/129) for detecting subacute microembolic lesions. No susceptibility artifacts were noticed in STEAM-DWI. Conclusion: Compared to standard EPI-DWI, STEAM-DWI offers a more robustAbstract: Introduction: Diffusion-weighted imaging in stimulated echo acquisition mode (STEAM-DWI) is an interesting alternative with less susceptibility artifacts compared to the most commonly used diffusion-weighted echo-planar imaging (EPI-DWI). Sensitivity and specificity of a novel STEAM-DWI, described by Merrem et al. 2017 [1], were assessed in patients with ischemic stroke. Methods: EPI- and STEAM-DWIs were performed in patients with suspected subacute stroke between 01 July 2019 and 30 June 2020 using 3-T MRI. Three neuroradiologists independently and separately rated STEAM-DWI images with respect to (i) signs of an acute/subacute stroke, (ii) the number, size and localization of infarctions and, (iii) the presence of artifacts. Results: In 55 (23 right, 23 left, 9 both hemispheres) of 85 patients a subacute stroke was confirmed using EPI-DWI. The cerebral vascular territories were affected as follows: anterior cerebral artery 8 %, middle cerebral artery 48 %, posterior cerebral artery 27 %, brainstem 7 %, cerebellum 10 %. In 53 of 55 (96 %) cases the stroke was detected by usage of STEAM-DWI, in 35 of 37 patients microembolic events were noticed (95 %). Results showed a sensitivity and specificity of 100 % (70/70) for major infarcts (>9 mm² in-plane) and a sensitivity of up to 94 % (121/129) for detecting subacute microembolic lesions. No susceptibility artifacts were noticed in STEAM-DWI. Conclusion: Compared to standard EPI-DWI, STEAM-DWI offers a more robust alternative for diagnosing subacute strokes in areas affected by susceptibility artifacts. … (more)
- Is Part Of:
- European journal of radiology. Issue 139(2021)
- Journal:
- European journal of radiology
- Issue:
- Issue 139(2021)
- Issue Display:
- Volume 139, Issue 139 (2021)
- Year:
- 2021
- Volume:
- 139
- Issue:
- 139
- Issue Sort Value:
- 2021-0139-0139-0000
- Page Start:
- Page End:
- Publication Date:
- 2021-06
- Subjects:
- STEAM -- Stroke -- DWI -- Susceptibility -- Artifacts
Medical radiology -- Periodicals
Radiology -- Periodicals
Radiologie médicale -- Périodiques
Medical radiology
Periodicals
616.075705 - Journal URLs:
- http://www.sciencedirect.com/science/journal/0720048X ↗
http://www.elsevier.com/homepage/elecserv.htt ↗
http://www.clinicalkey.com/dura/browse/journalIssue/0720048X ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/0720048X ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.ejrad.2021.109677 ↗
- Languages:
- English
- ISSNs:
- 0720-048X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3829.738050
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 22881.xml