Interscan measurement error of knee cartilage thickness and projected cartilage area ratio at 9 regions and 45 subregions by fully automatic three-dimensional MRI analysis. Issue 139 (June 2021)
- Record Type:
- Journal Article
- Title:
- Interscan measurement error of knee cartilage thickness and projected cartilage area ratio at 9 regions and 45 subregions by fully automatic three-dimensional MRI analysis. Issue 139 (June 2021)
- Main Title:
- Interscan measurement error of knee cartilage thickness and projected cartilage area ratio at 9 regions and 45 subregions by fully automatic three-dimensional MRI analysis
- Authors:
- Sekiya, Ichiro
Kohno, Yuji
Hyodo, Akinobu
Katano, Hisako
Komori, Keiichiro
Koga, Hideyuki
Tomita, Makoto
Suzuki, Kenji
Masumoto, Jun
Ozeki, Nobutake - Abstract:
- Abstract: Background: We have developed a fully automatic three-dimensional MRI analysis software program for automatic segmentation of knee cartilage using a deep neural network. The purpose of this study was to use this software to clarify the interscan measurement error of the knee cartilage thickness and projected cartilage area ratio at 9 regions and 45 subregions in the knee. Methods: Ten healthy volunteers underwent MRI twice in the same day. The software provided cartilage thickness and projected cartilage area ratio (thickness ≥ 1.5 mm) at 9 regions and 45 subregions of the knee without any manual correction. The interscan measurement error was calculated at each region and subregion from the data of nine donors, except for one donor who had body motion during the MRI examination. Results: The interscan measurement error of cartilage thickness was less than 0.10 mm at all 9 regions and at 39 subregions among 45 subregions. The measurement errors ranged from 0.03 to 0.21 mm. The intraclass correlation coefficients (ICC) of cartilage thickness were higher than 0.75 at all 9 regions and 41 subregions. The interscan measurement error of the projected cartilage area ratio ranged from 0.01 to 0.03 for all 9 regions. Conclusions: This study clarified the interscan measurement error of the knee cartilage thickness and projected cartilage area ratio.
- Is Part Of:
- European journal of radiology. Issue 139(2021)
- Journal:
- European journal of radiology
- Issue:
- Issue 139(2021)
- Issue Display:
- Volume 139, Issue 139 (2021)
- Year:
- 2021
- Volume:
- 139
- Issue:
- 139
- Issue Sort Value:
- 2021-0139-0139-0000
- Page Start:
- Page End:
- Publication Date:
- 2021-06
- Subjects:
- Interscan error -- Knee -- Cartilage -- Thickness -- Automatic -- 3D MRI
Medical radiology -- Periodicals
Radiology -- Periodicals
Radiologie médicale -- Périodiques
Medical radiology
Periodicals
616.075705 - Journal URLs:
- http://www.sciencedirect.com/science/journal/0720048X ↗
http://www.elsevier.com/homepage/elecserv.htt ↗
http://www.clinicalkey.com/dura/browse/journalIssue/0720048X ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/0720048X ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.ejrad.2021.109700 ↗
- Languages:
- English
- ISSNs:
- 0720-048X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3829.738050
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 22881.xml