Comparison of pre- and post-contrast-enhanced attenuation correction using a CAIPI-accelerated T1-weighted Dixon 3D-VIBE sequence in 68Ga-DOTATOC PET/MRI. Issue 139 (June 2021)
- Record Type:
- Journal Article
- Title:
- Comparison of pre- and post-contrast-enhanced attenuation correction using a CAIPI-accelerated T1-weighted Dixon 3D-VIBE sequence in 68Ga-DOTATOC PET/MRI. Issue 139 (June 2021)
- Main Title:
- Comparison of pre- and post-contrast-enhanced attenuation correction using a CAIPI-accelerated T1-weighted Dixon 3D-VIBE sequence in 68Ga-DOTATOC PET/MRI
- Authors:
- Bruckmann, Nils Martin
Lindemann, Maike E.
Grueneisen, Johannes
Grafe, Hong
Li, Yan
Sawicki, Lino M.
Rischpler, Christoph
Herrmann, Ken
Umutlu, Lale
Quick, Harald H.
Schaarschmidt, Benedikt Michael - Abstract:
- Abstract: Objectives: To investigate the influence of contrast agent administration on attenuation correction (AC) based on a CAIPIRINHA (CAIPI)-accelerated T1-weighted Dixon 3D-VIBE sequence in 68 Ga-DOTATOC PET/MRI. Material and methods: Fifty-one patients with neuroendocrine tumors underwent whole-body 68 Ga-DOTATOC PET/MRI for tumor staging. Two PET reconstructions were performed using AC-maps that were created using a high-resolution CAIPI-accelerated Dixon-VIBE sequence with an additional bone atlas and truncation correction using the HUGE (B0 homogenization using gradient enhancement) method before and after application of Gadolinium (Gd)-based contrast agent. Standardized uptake values (SUVs) of 21 volumes of interest (VOIs) were compared between in both PET data sets per patient. A student's t -test for paired samples was performed to test for potential differences between both AC-maps and both reconstructed PET data sets. Bonferroni correction was performed to prevent α-error accumulation, p < 0.0024 was considered to indicate statistical significance. Results: Significant quantitative differences between SUVmax were found in the perirenal fat (19.65 ± 48.03 %, p < 0.0001), in the axillary fat (17.46 ± 63.67 %, p < 0.0001) and in the dorsal subcutaneous fat on level of lumbar vertebral body L4 (10.26 ± 25.29 %, p < 0.0001). Significant differences were also evident in the lungs apical (5.80 ± 10.53 %, p < 0.0001), dorsal at the level of the pulmonary trunkAbstract: Objectives: To investigate the influence of contrast agent administration on attenuation correction (AC) based on a CAIPIRINHA (CAIPI)-accelerated T1-weighted Dixon 3D-VIBE sequence in 68 Ga-DOTATOC PET/MRI. Material and methods: Fifty-one patients with neuroendocrine tumors underwent whole-body 68 Ga-DOTATOC PET/MRI for tumor staging. Two PET reconstructions were performed using AC-maps that were created using a high-resolution CAIPI-accelerated Dixon-VIBE sequence with an additional bone atlas and truncation correction using the HUGE (B0 homogenization using gradient enhancement) method before and after application of Gadolinium (Gd)-based contrast agent. Standardized uptake values (SUVs) of 21 volumes of interest (VOIs) were compared between in both PET data sets per patient. A student's t -test for paired samples was performed to test for potential differences between both AC-maps and both reconstructed PET data sets. Bonferroni correction was performed to prevent α-error accumulation, p < 0.0024 was considered to indicate statistical significance. Results: Significant quantitative differences between SUVmax were found in the perirenal fat (19.65 ± 48.03 %, p < 0.0001), in the axillary fat (17.46 ± 63.67 %, p < 0.0001) and in the dorsal subcutaneous fat on level of lumbar vertebral body L4 (10.26 ± 25.29 %, p < 0.0001). Significant differences were also evident in the lungs apical (5.80 ± 10.53 %, p < 0.0001), dorsal at the level of the pulmonary trunk (15.04 ± 19.09 %, p < 0.0001) and dorsal in the basal lung (51.27 ± 147.61 %, p < 0.0001). Conclusion: The administration of (Gd)-contrast agents in this study has shown a considerable influence on the AC-maps in PET/MRI and, consequently impacted quantification in the reconstructed PET data. Therefore, dedicated PET/MRI staging protocols have to be adjusted so that AC-map acquisition is performed prior to contrast agent administration. … (more)
- Is Part Of:
- European journal of radiology. Issue 139(2021)
- Journal:
- European journal of radiology
- Issue:
- Issue 139(2021)
- Issue Display:
- Volume 139, Issue 139 (2021)
- Year:
- 2021
- Volume:
- 139
- Issue:
- 139
- Issue Sort Value:
- 2021-0139-0139-0000
- Page Start:
- Page End:
- Publication Date:
- 2021-06
- Subjects:
- PET/MRI -- Attenuation correction -- Contrast agent
Medical radiology -- Periodicals
Radiology -- Periodicals
Radiologie médicale -- Périodiques
Medical radiology
Periodicals
616.075705 - Journal URLs:
- http://www.sciencedirect.com/science/journal/0720048X ↗
http://www.elsevier.com/homepage/elecserv.htt ↗
http://www.clinicalkey.com/dura/browse/journalIssue/0720048X ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/0720048X ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.ejrad.2021.109691 ↗
- Languages:
- English
- ISSNs:
- 0720-048X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3829.738050
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 22881.xml