A cell model in the ventral visual pathway for the detection of circles of curvature constituting figures. Issue 11 (November 2020)
- Record Type:
- Journal Article
- Title:
- A cell model in the ventral visual pathway for the detection of circles of curvature constituting figures. Issue 11 (November 2020)
- Main Title:
- A cell model in the ventral visual pathway for the detection of circles of curvature constituting figures
- Authors:
- Kawakami, Susumu
Ito, Takehiro
Makino, Yoshinari
Hashimoto, Makoto
Yano, Masafumi - Abstract:
- Abstract: The contour of an arbitrary figure can be represented as a group of circles of curvature in contact with it, with each curvature circle represented by its center OC and radius r. We propose a series of cell models for detecting this circle, which is composed of a lateral geniculate nucleus (LGN) cell, nondirectionally selective (NDS) simple cell, and curvature-circle detection cell (CDC). The LGN and NDS simple cells were previously modeled. The CDC has been modeled as follows. Each tangent in contact with this circle is detected by an NDS simple cell that performs the Hough transformation of LGN cell responses, and then this tangent is transformed to a three-dimensional (3D) normal line in a CDC column. This transformation has been named a 3D normal-line transform. Performing this transformation for all tangents causes a CDC at the intersection of these normal lines to fire most intensively, and thus the OC and r of the circle is detected as the coordinates of this intersection. Therefore, the CDC has been modeled as this 3D normal-line transform. Based on this CDC, we model two types of constancy CDC: a position-invariant CDC and a curvature-invariant CDC. These three types of CDC reflect the response to various stimuli in actual area V4 cells. In order to validate these CDC types neurophysiologically, we propose an experimental method using microelectrodes. Cell models previously reported correspond to this hierarchy: the S1, S2, and C2 cells correspond to theAbstract: The contour of an arbitrary figure can be represented as a group of circles of curvature in contact with it, with each curvature circle represented by its center OC and radius r. We propose a series of cell models for detecting this circle, which is composed of a lateral geniculate nucleus (LGN) cell, nondirectionally selective (NDS) simple cell, and curvature-circle detection cell (CDC). The LGN and NDS simple cells were previously modeled. The CDC has been modeled as follows. Each tangent in contact with this circle is detected by an NDS simple cell that performs the Hough transformation of LGN cell responses, and then this tangent is transformed to a three-dimensional (3D) normal line in a CDC column. This transformation has been named a 3D normal-line transform. Performing this transformation for all tangents causes a CDC at the intersection of these normal lines to fire most intensively, and thus the OC and r of the circle is detected as the coordinates of this intersection. Therefore, the CDC has been modeled as this 3D normal-line transform. Based on this CDC, we model two types of constancy CDC: a position-invariant CDC and a curvature-invariant CDC. These three types of CDC reflect the response to various stimuli in actual area V4 cells. In order to validate these CDC types neurophysiologically, we propose an experimental method using microelectrodes. Cell models previously reported correspond to this hierarchy: the S1, S2, and C2 cells correspond to the NDS simple cell, CDC, and position-invariant CDC, respectively. Abstract : Cell model, Curvature-circle detection, 3D normal-line transform, Column, Coarse-to-fine extraction, Cell-array conversion, Shape recognition, Information systems, Behavioral neuroscience, Nervous system, Cognition, Consciousness, Emotion, Systems neuroscience, Mathematical biosciences. … (more)
- Is Part Of:
- Heliyon. Volume 6:Issue 11(2020)
- Journal:
- Heliyon
- Issue:
- Volume 6:Issue 11(2020)
- Issue Display:
- Volume 6, Issue 11 (2020)
- Year:
- 2020
- Volume:
- 6
- Issue:
- 11
- Issue Sort Value:
- 2020-0006-0011-0000
- Page Start:
- Page End:
- Publication Date:
- 2020-11
- Subjects:
- Cell model -- Curvature-circle detection -- 3D normal-line transform -- Column -- Coarse-to-fine extraction -- Cell-array conversion -- Shape recognition -- Information systems -- Behavioral neuroscience -- Nervous system -- Cognition -- Consciousness -- Emotion -- Systems neuroscience -- Mathematical biosciences
Research -- Periodicals
Medical sciences -- Periodicals
Natural history -- Periodicals
Social sciences -- Periodicals
Earth sciences -- Periodicals
Physical sciences -- Periodicals
507.2 - Journal URLs:
- http://www.sciencedirect.com/science/journal/24058440/ ↗
http://www.sciencedirect.com/ ↗ - DOI:
- 10.1016/j.heliyon.2020.e05397 ↗
- Languages:
- English
- ISSNs:
- 2405-8440
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 22896.xml