In vivo triglyceride composition of abdominal adipose tissue measured by 1H MRS at 3T. Issue 5 (29th August 2016)
- Record Type:
- Journal Article
- Title:
- In vivo triglyceride composition of abdominal adipose tissue measured by 1H MRS at 3T. Issue 5 (29th August 2016)
- Main Title:
- In vivo triglyceride composition of abdominal adipose tissue measured by 1H MRS at 3T
- Authors:
- Hamilton, Gavin
Schlein, Alexandra N.
Middleton, Michael S.
Hooker, Catherine A.
Wolfson, Tanya
Gamst, Anthony C.
Loomba, Rohit
Sirlin, Claude B. - Abstract:
- Abstract : Purpose: To investigate the regional variability of adipose tissue triglyceride composition in vivo using 1 H MRS, examining potential confounders and corrections for artifacts, to allow for adipose tissue spectrum estimation. Materials and Methods: 1 H magnetic resonance (MR) stimulated echo acquisition mode (STEAM) spectra were acquired in vivo at 3T from 340 adult patients (mean age 48.9 years, range 21–79 years; 172 males, 168 females; mean body mass index [BMI] 34.0, range 22–49 kg/m 2 ) with known or suspected nonalcoholic fatty liver disease (NAFLD) in deep (dSCAT), surface (sSCAT) subcutaneous adipose tissue, and visceral adipose tissue (VAT). Triglyceride composition was characterized by the number of double bonds (ndb) and number of methylene‐interrupted double bonds (nmidb). A subset of patients (dSCAT n = 80, sSCAT n = 55, VAT n = 194) had the acquisition repeated three times to examine the repeatability of ndb and nmidb estimation. Results: Mean ndb and nmidb showed significant ( P < 0.0001) differences between depots except for dSCAT and sSCAT nmidb (dSCAT ndb 2.797, nmidb 0.745; sSCAT ndb 2.826, nmidb 0.737; VAT ndb 2.723, nmidb 0.687). All ndb and nmidb estimates were highly repeatable (VAT ndb ICC = 0.888, nmidb ICC = 0.853; sSCAT: ndb ICC = 0.974, nmidb ICC = 0.964; dSCAT: ndb ICC = 0.959, nmidb ICC = 0.948). Conclusion: Adipose tissue composition can be estimated repeatably using 1 H MRS and different fat depots have different triglycerideAbstract : Purpose: To investigate the regional variability of adipose tissue triglyceride composition in vivo using 1 H MRS, examining potential confounders and corrections for artifacts, to allow for adipose tissue spectrum estimation. Materials and Methods: 1 H magnetic resonance (MR) stimulated echo acquisition mode (STEAM) spectra were acquired in vivo at 3T from 340 adult patients (mean age 48.9 years, range 21–79 years; 172 males, 168 females; mean body mass index [BMI] 34.0, range 22–49 kg/m 2 ) with known or suspected nonalcoholic fatty liver disease (NAFLD) in deep (dSCAT), surface (sSCAT) subcutaneous adipose tissue, and visceral adipose tissue (VAT). Triglyceride composition was characterized by the number of double bonds (ndb) and number of methylene‐interrupted double bonds (nmidb). A subset of patients (dSCAT n = 80, sSCAT n = 55, VAT n = 194) had the acquisition repeated three times to examine the repeatability of ndb and nmidb estimation. Results: Mean ndb and nmidb showed significant ( P < 0.0001) differences between depots except for dSCAT and sSCAT nmidb (dSCAT ndb 2.797, nmidb 0.745; sSCAT ndb 2.826, nmidb 0.737; VAT ndb 2.723, nmidb 0.687). All ndb and nmidb estimates were highly repeatable (VAT ndb ICC = 0.888, nmidb ICC = 0.853; sSCAT: ndb ICC = 0.974, nmidb ICC = 0.964; dSCAT: ndb ICC = 0.959, nmidb ICC = 0.948). Conclusion: Adipose tissue composition can be estimated repeatably using 1 H MRS and different fat depots have different triglyceride compositions. Level of Evidence : 2 J. MAGN. RESON. IMAGING 2017;45:1455–1463 … (more)
- Is Part Of:
- Journal of magnetic resonance imaging. Volume 45:Issue 5(2017)
- Journal:
- Journal of magnetic resonance imaging
- Issue:
- Volume 45:Issue 5(2017)
- Issue Display:
- Volume 45, Issue 5 (2017)
- Year:
- 2017
- Volume:
- 45
- Issue:
- 5
- Issue Sort Value:
- 2017-0045-0005-0000
- Page Start:
- 1455
- Page End:
- 1463
- Publication Date:
- 2016-08-29
- Subjects:
- magnetic resonance spectroscopy -- adipose tissue -- triglyceride composition -- fatty acids
Magnetic resonance imaging -- Periodicals
616 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-2586 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/jmri.25453 ↗
- Languages:
- English
- ISSNs:
- 1053-1807
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5010.791000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 22892.xml