Modeling impacts of ventilation and filtration methods on energy use and airborne disease transmission in classrooms. (1st October 2022)
- Record Type:
- Journal Article
- Title:
- Modeling impacts of ventilation and filtration methods on energy use and airborne disease transmission in classrooms. (1st October 2022)
- Main Title:
- Modeling impacts of ventilation and filtration methods on energy use and airborne disease transmission in classrooms
- Authors:
- Pistochini, Theresa
Mande, Caton
Chakraborty, Subhrajit - Abstract:
- Abstract: Lowering the potential of airborne disease transmission in school buildings is especially important in the wake of the COVID-19 pandemic. The benefits of increased ventilation and filtration for reducing disease transmission compared to drawbacks of reduced thermal comfort and increased energy consumption and electricity demand are not well described. A comprehensive simulation of outdoor air ventilation rates and filtration methods was performed with a modified Wells-Riley equation and EnergyPlus building simulation to understand the trade-offs between infection probability and energy consumption for a simulated classroom in 13 cities across the US. A packaged heating, ventilation, and air conditioning unit was configured, sized, and simulated for each city to understand the impact of five ventilation flow rates and three filtration systems. Higher ventilation rates increased energy consumption and resulted in a high number of unmet heating and cooling hours in most cities (excluding Los Angeles and San Francisco). On average, across the 13 cities simulated, annual energy consumed by an improved filtration system was 31% lower than the energy consumed by 100% outdoor air ventilation. In addition, the infection probability was 29% lower with improved filtration. An economizer, which activates cooling based on an outdoor temperature setpoint, increased ventilation and reduced both energy consumption and infection probability. It was also concluded that ventilationAbstract: Lowering the potential of airborne disease transmission in school buildings is especially important in the wake of the COVID-19 pandemic. The benefits of increased ventilation and filtration for reducing disease transmission compared to drawbacks of reduced thermal comfort and increased energy consumption and electricity demand are not well described. A comprehensive simulation of outdoor air ventilation rates and filtration methods was performed with a modified Wells-Riley equation and EnergyPlus building simulation to understand the trade-offs between infection probability and energy consumption for a simulated classroom in 13 cities across the US. A packaged heating, ventilation, and air conditioning unit was configured, sized, and simulated for each city to understand the impact of five ventilation flow rates and three filtration systems. Higher ventilation rates increased energy consumption and resulted in a high number of unmet heating and cooling hours in most cities (excluding Los Angeles and San Francisco). On average, across the 13 cities simulated, annual energy consumed by an improved filtration system was 31% lower than the energy consumed by 100% outdoor air ventilation. In addition, the infection probability was 29% lower with improved filtration. An economizer, which activates cooling based on an outdoor temperature setpoint, increased ventilation and reduced both energy consumption and infection probability. It was also concluded that ventilation and filtration measures better reduced absolute infection probability when the quanta generation rate for an infectious disease was higher. Dynamic outdoor airflow rate controls and filtration technologies that consider both health and energy consumption are an important area for further research. Highlights: Supplying 100% outdoor air increased average HVAC energy use by 45% for 13 cities. In Los Angeles and San Francisco, HVAC energy use decreased with increased ventilation. Economizers reduce both HVAC energy use and infectious disease transmission risk. Increased filtration efficiently reduced disease transmission risk. … (more)
- Is Part Of:
- Journal of building engineering. Volume 57(2022)
- Journal:
- Journal of building engineering
- Issue:
- Volume 57(2022)
- Issue Display:
- Volume 57, Issue 2022 (2022)
- Year:
- 2022
- Volume:
- 57
- Issue:
- 2022
- Issue Sort Value:
- 2022-0057-2022-0000
- Page Start:
- Page End:
- Publication Date:
- 2022-10-01
- Subjects:
- Indoor air quality -- Ventilation -- Filtration -- Infectious disease transmission -- Packaged HVAC -- Economizers
Building -- Periodicals
690.05 - Journal URLs:
- http://www.sciencedirect.com/science/journal/23527102 ↗
http://www.sciencedirect.com/ ↗ - DOI:
- 10.1016/j.jobe.2022.104840 ↗
- Languages:
- English
- ISSNs:
- 2352-7102
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 22790.xml