Overweight and obesity as protective factors against mortality in nonischemic cardiomyopathy patients with an implantable cardioverter defibrillator. Issue 12 (16th September 2020)
- Record Type:
- Journal Article
- Title:
- Overweight and obesity as protective factors against mortality in nonischemic cardiomyopathy patients with an implantable cardioverter defibrillator. Issue 12 (16th September 2020)
- Main Title:
- Overweight and obesity as protective factors against mortality in nonischemic cardiomyopathy patients with an implantable cardioverter defibrillator
- Authors:
- Zhou, Bin
Zhao, Shuang
Tang, Min
Chen, Keping
Hua, Wei
Su, Yangang
Chen, Silin
Liang, Zhaoguang
Xu, Wei
Li, Xiaoyao
Xue, Xiaodi
Sun, Xuerong
Zhang, Shu - Abstract:
- Abstract: Background: Previous studies have reported inconsistent results on the relationship between body mass index (BMI) and clinical outcomes in implantable cardioverter defibrillator (ICD) patients. Additionally, research on ICD patients with nonischemic cardiomyopathy (NICM) is lacking. Hypothesis: This study aimed to investigate the impact of BMI on mortality and ventricular arrhythmias (VAs) in NICM patients with an ICD. Methods: This study retrospectively analyzed the data from the Study of Home Monitoring System Safety and Efficacy in Cardiac Implantable Electronic Device‐implanted patients (SUMMIT) in China. Four hundred and eighty NICM patients with an ICD having BMI data were enrolled. Patients were divided into two groups: underweight and normal range group (BMI < 24 kg/m 2 ), overweight and obese group (BMI≥24 kg/m 2 ). The primary endpoint was all‐cause mortality. The secondary endpoint was the first occurrence of VAs requiring appropriate ICD therapy or shock. Results: During a median follow‐up of 61 (1‐95) months, 70 patients (14.6%) died, 173 patients (36%) experienced VAs requiring appropriate ICD therapy, and 112 patients (23.3%) were treated with ICD shock. Multivariate Cox regression modeling indicated a decreased mortality risk in the overweight and obese group compared with the underweight and normal range group (hazard ratio = 0.44, 95% confidence interval 0.26‐0.77, P = .003). However, the risk of VAs was similar in both groups in univariate andAbstract: Background: Previous studies have reported inconsistent results on the relationship between body mass index (BMI) and clinical outcomes in implantable cardioverter defibrillator (ICD) patients. Additionally, research on ICD patients with nonischemic cardiomyopathy (NICM) is lacking. Hypothesis: This study aimed to investigate the impact of BMI on mortality and ventricular arrhythmias (VAs) in NICM patients with an ICD. Methods: This study retrospectively analyzed the data from the Study of Home Monitoring System Safety and Efficacy in Cardiac Implantable Electronic Device‐implanted patients (SUMMIT) in China. Four hundred and eighty NICM patients with an ICD having BMI data were enrolled. Patients were divided into two groups: underweight and normal range group (BMI < 24 kg/m 2 ), overweight and obese group (BMI≥24 kg/m 2 ). The primary endpoint was all‐cause mortality. The secondary endpoint was the first occurrence of VAs requiring appropriate ICD therapy or shock. Results: During a median follow‐up of 61 (1‐95) months, 70 patients (14.6%) died, 173 patients (36%) experienced VAs requiring appropriate ICD therapy, and 112 patients (23.3%) were treated with ICD shock. Multivariate Cox regression modeling indicated a decreased mortality risk in the overweight and obese group compared with the underweight and normal range group (hazard ratio = 0.44, 95% confidence interval 0.26‐0.77, P = .003). However, the risk of VAs was similar in both groups in univariate and multivariate Cox models. Conclusions: Compared with underweight and normal weight, overweight and obesity are protective against mortality but have only a neutral impact on VAs risk in NICM patients with an ICD. … (more)
- Is Part Of:
- Clinical cardiology. Volume 43:Issue 12(2020)
- Journal:
- Clinical cardiology
- Issue:
- Volume 43:Issue 12(2020)
- Issue Display:
- Volume 43, Issue 12 (2020)
- Year:
- 2020
- Volume:
- 43
- Issue:
- 12
- Issue Sort Value:
- 2020-0043-0012-0000
- Page Start:
- 1435
- Page End:
- 1442
- Publication Date:
- 2020-09-16
- Subjects:
- body mass index -- implantable cardioverter defibrillator -- mortality -- nonischemic cardiomyopathy
Cardiology -- Periodicals
616.12005 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1932-8737/issues ↗
http://www3.interscience.wiley.com/journal/113412417/home ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/clc.23458 ↗
- Languages:
- English
- ISSNs:
- 0160-9289
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3286.265000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 22792.xml