Water quality assessment using synchrotron‐based TXRF. (7th July 2022)
- Record Type:
- Journal Article
- Title:
- Water quality assessment using synchrotron‐based TXRF. (7th July 2022)
- Main Title:
- Water quality assessment using synchrotron‐based TXRF
- Authors:
- Garg, Vijay Kumar
Tanta, Ankush
Lal Srivastav, Arun
Tiwari, M. K.
Sharma, Ajay
Kanwar, Varinder Singh - Abstract:
- Abstract: The pollutants released from pharmaceutical, steel, paper, and battery industries into water cause stress on the natural ecosystems, may mix with soil and water, enter into human food chain, and hence cause irreparable damage to the biotic system. Hence, the appropriate monitoring of water along with determination of heavy metals is very important for human beings. In present paper, total reflection X‐ray fluorescence (TXRF) spectrometry technique is employed to determine the level of different contaminants in the water samples gathered from the various sites of an identified industrial area. Experimentation is carried out at Raja Ramanna Centre for Advanced Technology (RRCAT), Indore‐India by using TXRF, which is one the advance techniques of element determination up to ppb levels. The elemental concentration of Cl, K, Ca, Fe, Cu, Zn, Ga, Br, Sr, As, Pb, and Ni is quantified and compared with the limits established by the WHO (World Health Organization) and BIS (Bureau of Indian Standard) guidelines regarding drinking water use. The levels of the Pb, Fe, As, Ni, Cr, Co, and Mn exceeded the values suggested by WHO and BIS at some locations/sites. To better understand the situation, water quality parameters such as Water Quality Index (WQI), Heavy metal Pollution Index (HPI), Contamination Index (CI), Metal Enrichment Index (MEI), and Heavy Metal Evaluation Index (HEI) have also been assessed for all the sites close to industrial hub. Among all sites except at A3Abstract: The pollutants released from pharmaceutical, steel, paper, and battery industries into water cause stress on the natural ecosystems, may mix with soil and water, enter into human food chain, and hence cause irreparable damage to the biotic system. Hence, the appropriate monitoring of water along with determination of heavy metals is very important for human beings. In present paper, total reflection X‐ray fluorescence (TXRF) spectrometry technique is employed to determine the level of different contaminants in the water samples gathered from the various sites of an identified industrial area. Experimentation is carried out at Raja Ramanna Centre for Advanced Technology (RRCAT), Indore‐India by using TXRF, which is one the advance techniques of element determination up to ppb levels. The elemental concentration of Cl, K, Ca, Fe, Cu, Zn, Ga, Br, Sr, As, Pb, and Ni is quantified and compared with the limits established by the WHO (World Health Organization) and BIS (Bureau of Indian Standard) guidelines regarding drinking water use. The levels of the Pb, Fe, As, Ni, Cr, Co, and Mn exceeded the values suggested by WHO and BIS at some locations/sites. To better understand the situation, water quality parameters such as Water Quality Index (WQI), Heavy metal Pollution Index (HPI), Contamination Index (CI), Metal Enrichment Index (MEI), and Heavy Metal Evaluation Index (HEI) have also been assessed for all the sites close to industrial hub. Among all sites except at A3 and A6, WQI is found to be much greater than WHO and BIS established limit. Level of arsenic in the water at A1 location was found 73 ppb. However, lead metal in water was found to be very high at all the six studied locations, and at A1 location, it is found extremely high 2613 ppb. Therefore, water at A1 and A2 sites is found to be unfit for drinking. Practitioner Points: Total reflection X‐ray fluorescence (TXRF) spectrometry technique is employed to determine the level of different contaminants in the water samples The elemental concentration of Cl, K, Ca, Fe, Cu, Zn, Ga, Br, Sr, As, Pb, and Ni is quantified and compared with the limits prescribed by the WHO Water Quality Index (WQI), Heavy metal Pollution Index (HPI), Contamination Index (CI), Metal Enrichment Index (MEI), and Heavy Metal Enrichment Index (MEI) have also been assessed for all the sites Water at some sites is found unfit for drinking purpose. Based on the observations, some remedial measures are suggested to reduce the level of water contaminants up to desired levels. Abstract : Total reflection X‐ray fluorescence spectrometry (TXRF) technique is employed to determine the level of different contaminants in the water samples. The elemental concentration of Cl, K, Ca, Fe, Cu, Zn, Ga, Br, Sr, As, Pb, and Ni is quantified and compared with the limits prescribed by the World Health Organization (WHO). Water Quality Index (WQI), Heavy metal Pollution Index (HPI), Contamination Index (CI), Metal Enrichment Index (MEI), and Heavy Metal Enrichment Index (MEI) have also been assessed for all the sites. Water at some sites is found unfit for drinking purpose. Based on the observations, some remedial measures are suggested to reduce the level of water contaminants up to desired levels. … (more)
- Is Part Of:
- Water environment research. Volume 94:Number 7(2022)
- Journal:
- Water environment research
- Issue:
- Volume 94:Number 7(2022)
- Issue Display:
- Volume 94, Issue 7 (2022)
- Year:
- 2022
- Volume:
- 94
- Issue:
- 7
- Issue Sort Value:
- 2022-0094-0007-0000
- Page Start:
- n/a
- Page End:
- n/a
- Publication Date:
- 2022-07-07
- Subjects:
- heavy metal -- synchrotron radiation -- water and X‐ray fluorescence
Water quality management -- Periodicals
Water -- Purification -- Periodicals
Water -- Pollution -- Periodicals
Water -- Pollution
Water -- Purification
Water quality management
Sewage
Water Pollution
Periodicals
Electronic journals
Periodicals
628.16 - Journal URLs:
- https://onlinelibrary.wiley.com/journal/15547531 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/wer.10759 ↗
- Languages:
- English
- ISSNs:
- 1061-4303
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 9270.004600
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 22774.xml