Patent ductus arteriosus stenting versus modified Blalock–Taussig shunt for palliation of duct‐dependent pulmonary blood flow lesions. Issue 9 (21st June 2022)
- Record Type:
- Journal Article
- Title:
- Patent ductus arteriosus stenting versus modified Blalock–Taussig shunt for palliation of duct‐dependent pulmonary blood flow lesions. Issue 9 (21st June 2022)
- Main Title:
- Patent ductus arteriosus stenting versus modified Blalock–Taussig shunt for palliation of duct‐dependent pulmonary blood flow lesions
- Authors:
- Helal, Abdelmonem M.
Elmahrouk, Ahmed F.
Bekheet, Samia
Barnawi, Hani I.
Jamjoom, Ahmed A.
Galal, Mohammed O.
Abou Zahr, Riad - Abstract:
- Abstract: Background: Patent ductus arteriosus (PDA) stenting is an alternative to modified Blalock–Taussig shunt (MBTS) as first‐stage palliation of duct‐dependent lesions. The superiority of one approach over the other is still controversial. Our objective was to compare PDA stent versusMBTS for palliation in regard to safety, efficacy, and efficiency. Methods: From 2010 to 2021, 134 patients had first‐stage palliation with either PDA stent ( n = 83) or MBTS ( n = 51). Twenty‐seven patients failed the primary treatment and were converted to the other group. The study endpoints were hospital outcomes, interstage reintervention, and concomitant procedures at the second‐stage palliation. Results: Patients with PDA stent were significantly younger. The prevalence of antegrade pulmonary blood flow (PBF) was higher in patients who had MBTS and graft thrombosis was higher in the PDA stent. Hospital stay was significantly longer in patients who had MBTS. Predictors of prolonged mechanical ventilation were low‐weight, MBTS, and conversion. Intensive care unit stay significantly increased with conversion, low‐weight, and antegrade PBF. The interstage intervention was required more frequently in PDA‐stent group. Predictors of reintervention were conversion and pulmonary atresia with the intact interventricular septum. Pulmonary artery plasty was required more frequently during the second‐stage palliation in PDA‐stent group. Conclusion: PDA stent is an alternative to MBTS forAbstract: Background: Patent ductus arteriosus (PDA) stenting is an alternative to modified Blalock–Taussig shunt (MBTS) as first‐stage palliation of duct‐dependent lesions. The superiority of one approach over the other is still controversial. Our objective was to compare PDA stent versusMBTS for palliation in regard to safety, efficacy, and efficiency. Methods: From 2010 to 2021, 134 patients had first‐stage palliation with either PDA stent ( n = 83) or MBTS ( n = 51). Twenty‐seven patients failed the primary treatment and were converted to the other group. The study endpoints were hospital outcomes, interstage reintervention, and concomitant procedures at the second‐stage palliation. Results: Patients with PDA stent were significantly younger. The prevalence of antegrade pulmonary blood flow (PBF) was higher in patients who had MBTS and graft thrombosis was higher in the PDA stent. Hospital stay was significantly longer in patients who had MBTS. Predictors of prolonged mechanical ventilation were low‐weight, MBTS, and conversion. Intensive care unit stay significantly increased with conversion, low‐weight, and antegrade PBF. The interstage intervention was required more frequently in PDA‐stent group. Predictors of reintervention were conversion and pulmonary atresia with the intact interventricular septum. Pulmonary artery plasty was required more frequently during the second‐stage palliation in PDA‐stent group. Conclusion: PDA stent is an alternative to MBTS for first‐stage palliation. It is associated with shorter hospital stays and avoidance of surgery at the expense of a high rate of stent thrombosis and interstage reintervention. Conversion increased the risk of the procedure. More studies are needed to determine factors that affect PDA‐stent outcomes and patient selection criteria. … (more)
- Is Part Of:
- Journal of cardiac surgery. Volume 37:Issue 9(2022)
- Journal:
- Journal of cardiac surgery
- Issue:
- Volume 37:Issue 9(2022)
- Issue Display:
- Volume 37, Issue 9 (2022)
- Year:
- 2022
- Volume:
- 37
- Issue:
- 9
- Issue Sort Value:
- 2022-0037-0009-0000
- Page Start:
- 2571
- Page End:
- 2580
- Publication Date:
- 2022-06-21
- Subjects:
- ductal‐dependent pulmonary blood flow -- modified Blalock–Taussig shunt -- PDA stenting
Heart -- Surgery -- Periodicals
617.412005 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1540-8191 ↗
http://www.blackwell-synergy.com/rd.asp?goto=journal&code=jcs ↗
http://onlinelibrary.wiley.com/ ↗
http://firstsearch.oclc.org ↗ - DOI:
- 10.1111/jocs.16692 ↗
- Languages:
- English
- ISSNs:
- 0886-0440
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4954.863500
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 22792.xml