Platinum Coating on an Ultrathin InN Epilayer as a Dual Gas Sensor for Selective Sensing of Ammonia and Acetone by Temperature Modulation for Liver Malfunction and Diabetes Applications. (1st January 2018)
- Record Type:
- Journal Article
- Title:
- Platinum Coating on an Ultrathin InN Epilayer as a Dual Gas Sensor for Selective Sensing of Ammonia and Acetone by Temperature Modulation for Liver Malfunction and Diabetes Applications. (1st January 2018)
- Main Title:
- Platinum Coating on an Ultrathin InN Epilayer as a Dual Gas Sensor for Selective Sensing of Ammonia and Acetone by Temperature Modulation for Liver Malfunction and Diabetes Applications
- Authors:
- Rai, Sujeet Kumar
Kao, K.W.
Agarwal, Ashish
Gwo, S.J.
Kumar, Amarendra
Yeh, J. Andrew - Abstract:
- Abstract : A platinum coating on an ultrathin InN resistive gas sensor was fabricated for the selective sensing of ammonia and acetone gas for liver malfunction and diabetes applications by using a temperature modulation technique. We use a cyclic temperature profile in the InN gas sensor heater, where the temperature varies from 200°C to 0°C and from 0°C to 200°C in increments of 50°C. Therefore, a different current variation response is measured on an InN epilayer for 5 ppm ammonia and 5 ppm acetone gas, respectively, because ammonia and acetone gas behave differently in the cyclic temperature profile. When ammonia and acetone gas are exposed in background air, the variation in the response of the current in different temperature regions is given as 2.5% for acetone gas and 7.85% for ammonia gas between 100°C to 150°C, and 12% for acetone gas and 8.85% for ammonia gas between 150°C to 200°C. Therefore, the temperature region 100°C to 150°C is suitable for selectively sensing ammonia gas for determining liver malfunction. The temperature range between 150°C to 200°C is suitable for selectively sensing acetone gas for the diabetes monitoring applications.
- Is Part Of:
- ECS journal of solid state science and technology. Volume 7:Number 7(2018)
- Journal:
- ECS journal of solid state science and technology
- Issue:
- Volume 7:Number 7(2018)
- Issue Display:
- Volume 7, Issue 7 (2018)
- Year:
- 2018
- Volume:
- 7
- Issue:
- 7
- Issue Sort Value:
- 2018-0007-0007-0000
- Page Start:
- Q3221
- Page End:
- Q3229
- Publication Date:
- 2018-01-01
- Subjects:
- Gas sensor -- liver malfunction -- diabetes -- selectivity -- breath VOCs
Solid state chemistry -- Periodicals
Electronics -- Materials -- Periodicals
Electrochemistry -- Periodicals
541.0421 - Journal URLs:
- https://iopscience.iop.org/journal/2162-8777 ↗
http://www.electrochem.org/ ↗ - DOI:
- 10.1149/2.0311807jss ↗
- Languages:
- English
- ISSNs:
- 2162-8777
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 22719.xml