Monitoring of a Historical Masonry Structure in Case of Induced Seismicity. Issue 1 (2nd January 2021)
- Record Type:
- Journal Article
- Title:
- Monitoring of a Historical Masonry Structure in Case of Induced Seismicity. Issue 1 (2nd January 2021)
- Main Title:
- Monitoring of a Historical Masonry Structure in Case of Induced Seismicity
- Authors:
- Bal, İhsan Engin
Dais, Dimitris
Smyrou, Eleni
Sarhosis, Vasilis - Abstract:
- ABSTRACT: In case of induced seismicity, expectations from a structural monitoring system are different than in the case of natural seismicity. In this paper, monitoring results of a historical building in Groningen (Netherlands) in case of induced seismicity has been presented. Results of the monitoring, particularities of the monitoring in case of induced earthquakes, as well as the usefulness and need of various monitoring systems for similar cases are discussed. Weak soil properties dominate the structural response in the region; thus, the ground water monitoring as well as the interaction of soil movements with the structural response has also been scrutinized. The proposed study could be effectively used to monitor historical structures subjected to induced seismicity and provide useful information to asset owners to classify the structural health condition of structures in their care. It was shown that the in-plane cracks at the building would normally not be expected in this structure during small induced earthquakes happening in Groningen. One explanation provided here is that the soil parameters, such as shrinking of water-sensitive soil layers, in combination with small earthquakes, may cause settlements. The soil effects may superimpose with the earthquake effects eventually causing small cracks and damage.
- Is Part Of:
- International journal of architectural heritage. Volume 15:Issue 1(2021)
- Journal:
- International journal of architectural heritage
- Issue:
- Volume 15:Issue 1(2021)
- Issue Display:
- Volume 15, Issue 1 (2021)
- Year:
- 2021
- Volume:
- 15
- Issue:
- 1
- Issue Sort Value:
- 2021-0015-0001-0000
- Page Start:
- 187
- Page End:
- 204
- Publication Date:
- 2021-01-02
- Subjects:
- Historic structures -- induced seismicity -- masonry -- monitoring
Architecture -- Conservation and restoration -- Periodicals
Historic buildings -- Periodicals
Historic preservation -- Planning -- Periodicals
721.0288 - Journal URLs:
- http://www.tandfonline.com/toc/taen20/current ↗
http://www.informaworld.com/1558-3066 ↗
http://www.tandfonline.com/ ↗ - DOI:
- 10.1080/15583058.2020.1719230 ↗
- Languages:
- English
- ISSNs:
- 1558-3058
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4542.103400
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 22721.xml