Diagnostic yield of endoscopic ultrasound-guided tissue acquisition of solid pancreatic lesions after inconclusive percutaneous ultrasound-guided tissue acquisition. (1st September 2020)
- Record Type:
- Journal Article
- Title:
- Diagnostic yield of endoscopic ultrasound-guided tissue acquisition of solid pancreatic lesions after inconclusive percutaneous ultrasound-guided tissue acquisition. (1st September 2020)
- Main Title:
- Diagnostic yield of endoscopic ultrasound-guided tissue acquisition of solid pancreatic lesions after inconclusive percutaneous ultrasound-guided tissue acquisition
- Authors:
- Le Grazie, Marco
Conti Bellocchi, Maria Cristina
Bernardoni, Laura
Fusaroli, Pietro
Manfrin, Erminia
Pallio, Socrate
Gabbrielli, Armando
Crinò, Stefano Francesco - Abstract:
- Abstract: Introduction: After a failed percutaneous ultrasound (US)-guided sampling, it is recommended that endoscopic ultrasound (EUS)-guided tissue acquisition (TA) be performed for non-resectable solid pancreatic lesions according to the European Federation of Societies for Ultrasound in Medicine and Biology. However, the diagnostic performance of EUS-guided TA in this setting is unknown. Methods: We retrospectively analyzed the performance and safety of EUS-guided TA in patients with a previous failed percutaneous biopsy. We also evaluated the diagnostic delays between the percutaneous approach and EUS diagnosis. Results: Over a period of 2 years, 49 patients were identified (29 males, mean age 65 years). The reasons for failure of percutaneous sampling were inadequate samples in 25 (52.1%) cases and lesions that were not visible or targetable in 24 (47.9%) cases. In one case, EUS-guided TA was not performed because of the interposition of a metallic biliary stent. No adverse events were recorded for both the percutaneous and EUS approaches. The median diagnostic delay was 12 days. Overall, the sensitivity and accuracy of EUS-guided TA were 92.7 and 93.7%, respectively. A subgroup analysis examined cases with inadequate samples obtained with the percutaneous approach, and the sensitivity and accuracy of EUS-guided TA were 85.7 and 88%, respectively. Conclusion: EUS-guided TA is safe and accurate for the diagnosis of pancreatic lesions after a previous inconclusiveAbstract: Introduction: After a failed percutaneous ultrasound (US)-guided sampling, it is recommended that endoscopic ultrasound (EUS)-guided tissue acquisition (TA) be performed for non-resectable solid pancreatic lesions according to the European Federation of Societies for Ultrasound in Medicine and Biology. However, the diagnostic performance of EUS-guided TA in this setting is unknown. Methods: We retrospectively analyzed the performance and safety of EUS-guided TA in patients with a previous failed percutaneous biopsy. We also evaluated the diagnostic delays between the percutaneous approach and EUS diagnosis. Results: Over a period of 2 years, 49 patients were identified (29 males, mean age 65 years). The reasons for failure of percutaneous sampling were inadequate samples in 25 (52.1%) cases and lesions that were not visible or targetable in 24 (47.9%) cases. In one case, EUS-guided TA was not performed because of the interposition of a metallic biliary stent. No adverse events were recorded for both the percutaneous and EUS approaches. The median diagnostic delay was 12 days. Overall, the sensitivity and accuracy of EUS-guided TA were 92.7 and 93.7%, respectively. A subgroup analysis examined cases with inadequate samples obtained with the percutaneous approach, and the sensitivity and accuracy of EUS-guided TA were 85.7 and 88%, respectively. Conclusion: EUS-guided TA is safe and accurate for the diagnosis of pancreatic lesions after a previous inconclusive percutaneous approach. … (more)
- Is Part Of:
- Scandinavian journal of gastroenterology. Volume 55:Number 9(2020)
- Journal:
- Scandinavian journal of gastroenterology
- Issue:
- Volume 55:Number 9(2020)
- Issue Display:
- Volume 55, Issue 9 (2020)
- Year:
- 2020
- Volume:
- 55
- Issue:
- 9
- Issue Sort Value:
- 2020-0055-0009-0000
- Page Start:
- 1108
- Page End:
- 1113
- Publication Date:
- 2020-09-01
- Subjects:
- Pancreatic cancer -- fine-needle aspiration -- endoscopic ultrasound fine-needle biopsy -- interventional ultrasound -- precision medicine
Gastroenterology -- Periodicals
Digestive organs -- Diseases -- Periodicals
616.33 - Journal URLs:
- http://informahealthcare.com/loi/gas ↗
http://informahealthcare.com ↗ - DOI:
- 10.1080/00365521.2020.1794021 ↗
- Languages:
- English
- ISSNs:
- 0036-5521
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 8087.507000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 22702.xml