Evaluation of the performance of field olfactometers by selected ion flow tube mass spectrometry. (September 2015)
- Record Type:
- Journal Article
- Title:
- Evaluation of the performance of field olfactometers by selected ion flow tube mass spectrometry. (September 2015)
- Main Title:
- Evaluation of the performance of field olfactometers by selected ion flow tube mass spectrometry
- Authors:
- Walgraeve, Christophe
Van Huffel, Katrijn
Bruneel, Joren
Van Langenhove, Herman - Abstract:
- Abstract : Odour quantification is generally performed by olfactometry, a technique which determines to what extent an odorous air sample should be diluted with odour-free air to be just distinguishable from odour-free air. In this study, the performance of two field olfactometers (Nasal Ranger and Scentroid 110c) was evaluated with respect to their ability to generate accurate dilutions. Therefore, an air stream with known concentrations (500 ppbv –5 ppmv ) of odorous compounds (acetic acid, propanoic acid, n-butanol, dimethyl sulphide, dimethyl disulphide) was diluted by the olfactometers at their different set points after which the concentrations of the target compounds in the diluted air stream were measured by selected ion flow tube mass spectrometry (SIFT-MS). This enabled to determine the observed dilution ratios ( DR obs ) and relate them to the set point values ( DR set ). The Nasal Ranger showed good performance in the interval between DR set 3 and 31. Only at the highest set dilution ratio ( DR set = 61) breakthrough of the compounds through the activated carbon filter was observed. This breakthrough resulted in lower observed dilution ratios (up to a factor of 2 for dimethyl sulphide) when compared to the DR set . For the Scentroid a good linearity between DR set and DR obs was observed but dilution ratios were much higher (up to a factor of 2) than what could be theoretically expected on the basis of air flows. This behaviour could be explained by sorptionAbstract : Odour quantification is generally performed by olfactometry, a technique which determines to what extent an odorous air sample should be diluted with odour-free air to be just distinguishable from odour-free air. In this study, the performance of two field olfactometers (Nasal Ranger and Scentroid 110c) was evaluated with respect to their ability to generate accurate dilutions. Therefore, an air stream with known concentrations (500 ppbv –5 ppmv ) of odorous compounds (acetic acid, propanoic acid, n-butanol, dimethyl sulphide, dimethyl disulphide) was diluted by the olfactometers at their different set points after which the concentrations of the target compounds in the diluted air stream were measured by selected ion flow tube mass spectrometry (SIFT-MS). This enabled to determine the observed dilution ratios ( DR obs ) and relate them to the set point values ( DR set ). The Nasal Ranger showed good performance in the interval between DR set 3 and 31. Only at the highest set dilution ratio ( DR set = 61) breakthrough of the compounds through the activated carbon filter was observed. This breakthrough resulted in lower observed dilution ratios (up to a factor of 2 for dimethyl sulphide) when compared to the DR set . For the Scentroid a good linearity between DR set and DR obs was observed but dilution ratios were much higher (up to a factor of 2) than what could be theoretically expected on the basis of air flows. This behaviour could be explained by sorption effects of the target compounds onto the metal parts and into the rubber seal of the Scentroid. Highlights: Performance of the Scentroid and Nasal Ranger field olfactometers studied. Breakthrough of the carbon filters affected the DR ob s of the Nasal Ranger. Observed dilution ratios were higher than the set point values for Scentroid. … (more)
- Is Part Of:
- Biosystems engineering. Volume 137(2015:Sep.)
- Journal:
- Biosystems engineering
- Issue:
- Volume 137(2015:Sep.)
- Issue Display:
- Volume 137 (2015)
- Year:
- 2015
- Volume:
- 137
- Issue Sort Value:
- 2015-0137-0000-0000
- Page Start:
- 84
- Page End:
- 94
- Publication Date:
- 2015-09
- Subjects:
- Nasal Ranger -- Scentroid -- Olfactometry -- SIFT-MS -- Mass spectrometry -- Odour
Bioengineering -- Periodicals
Agricultural engineering -- Periodicals
Biological systems -- Periodicals
Génie rural -- Périodiques
Systèmes biologiques -- Périodiques
631 - Journal URLs:
- http://www.sciencedirect.com/science/journal/15375110 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.biosystemseng.2015.07.007 ↗
- Languages:
- English
- ISSNs:
- 1537-5110
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 2089.670500
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 22686.xml