The inter-device reliability of global navigation satellite systems during team sport movement across multiple days. Issue 4 (April 2022)
- Record Type:
- Journal Article
- Title:
- The inter-device reliability of global navigation satellite systems during team sport movement across multiple days. Issue 4 (April 2022)
- Main Title:
- The inter-device reliability of global navigation satellite systems during team sport movement across multiple days
- Authors:
- Crang, Zachary L.
Duthie, Grant
Cole, Michael H.
Weakley, Jonathon
Hewitt, Adam
Johnston, Rich D. - Abstract:
- Abstract: Objectives: (1) Determine the inter-device and inter-manufacturer reliability; and (2) investigate the variation in reliability over time for common global navigation satellite systems. Design: Repeated measures. Methods: A total of twenty 10-Hz devices manufactured by StatSports (n = 10, Apex Pro; StatSports, Newry, Ireland) and Catapult Sports (n = 10, Vector S7; Catapult Sports, Melbourne, Australia) were towed on a sprint sled during 8 × 40-minute team sport movement protocol over a 4-week period. The coefficient of variations for distance, velocity and acceleration/deceleration metrics were calculated to show dispersion of the data relative to the mean or median for each manufacturer and interpreted as good, ≤5%; moderate, <10%; and poor, coefficient of variation ≥10%. The coefficient of variation range described the variation in reliability and was interpreted as small, ≤5%; moderate, <10% and large, ≥10%. Inter-manufacturer agreement was represented as a Cohen d (±95% confidence interval) standardised effect size. Results: Inter-device reliability for distance, peak velocity and average acceleration was good (coefficient of variation = 0.1 to 3.9%) for both manufacturers, with small variation across sessions. For most threshold-based acceleration and deceleration counts, StatSports devices showed good to moderate reliability, with moderate variation across sessions; Catapult showed good to poor reliability, with large variation across sessions.Abstract: Objectives: (1) Determine the inter-device and inter-manufacturer reliability; and (2) investigate the variation in reliability over time for common global navigation satellite systems. Design: Repeated measures. Methods: A total of twenty 10-Hz devices manufactured by StatSports (n = 10, Apex Pro; StatSports, Newry, Ireland) and Catapult Sports (n = 10, Vector S7; Catapult Sports, Melbourne, Australia) were towed on a sprint sled during 8 × 40-minute team sport movement protocol over a 4-week period. The coefficient of variations for distance, velocity and acceleration/deceleration metrics were calculated to show dispersion of the data relative to the mean or median for each manufacturer and interpreted as good, ≤5%; moderate, <10%; and poor, coefficient of variation ≥10%. The coefficient of variation range described the variation in reliability and was interpreted as small, ≤5%; moderate, <10% and large, ≥10%. Inter-manufacturer agreement was represented as a Cohen d (±95% confidence interval) standardised effect size. Results: Inter-device reliability for distance, peak velocity and average acceleration was good (coefficient of variation = 0.1 to 3.9%) for both manufacturers, with small variation across sessions. For most threshold-based acceleration and deceleration counts, StatSports devices showed good to moderate reliability, with moderate variation across sessions; Catapult showed good to poor reliability, with large variation across sessions. Inter-manufacturer agreement demonstrated moderate to very large effect sizes reported for most metrics. Conclusions: Reliability was suitable and consistent for measures of distance, velocity, and average acceleration. StatSports devices generally possessed suitable reliability and consistency for threshold-based accelerations and decelerations, though Catapult devices did not. Most metrics should not be compared between manufacturers. … (more)
- Is Part Of:
- Journal of science and medicine in sport. Volume 25:Issue 4(2022)
- Journal:
- Journal of science and medicine in sport
- Issue:
- Volume 25:Issue 4(2022)
- Issue Display:
- Volume 25, Issue 4 (2022)
- Year:
- 2022
- Volume:
- 25
- Issue:
- 4
- Issue Sort Value:
- 2022-0025-0004-0000
- Page Start:
- 340
- Page End:
- 344
- Publication Date:
- 2022-04
- Subjects:
- Wearable microtechnology -- Training -- Workload -- GPS -- Monitoring
Sports sciences -- Periodicals
Sports medicine -- Periodicals
Exercise -- Physiological aspects -- Periodicals
Sports -- physiology -- Periodicals
Sports Medicine -- Periodicals
Sportgeneeskunde
617.102705 - Journal URLs:
- http://www.sciencedirect.com/science/journal/14402440 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.jsams.2021.11.044 ↗
- Languages:
- English
- ISSNs:
- 1440-2440
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5054.840000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 22677.xml