Radiofrequency and microwave ablation in a porcine liver model: non-contrast CT and ultrasound radiologic-pathologic correlation. (1st January 2020)
- Record Type:
- Journal Article
- Title:
- Radiofrequency and microwave ablation in a porcine liver model: non-contrast CT and ultrasound radiologic-pathologic correlation. (1st January 2020)
- Main Title:
- Radiofrequency and microwave ablation in a porcine liver model: non-contrast CT and ultrasound radiologic-pathologic correlation
- Authors:
- Ziemlewicz, Timothy J.
Hinshaw, J. Louis
Lubner, Meghan G.
Knott, Emily A.
Willey, Bridgett J.
Lee, Fred T.
Brace, Christopher L. - Abstract:
- Abstract: Purpose: The goal of this study was to compare intra-procedural radiofrequency (RF) and microwave ablation appearance on non-contrast CT (NCCT) and ultrasound to the zone of pathologic necrosis. Materials and methods: Twenty-one 5-min ablations were performed in vivo in swine liver with (1) microwave at 140 W, (2) microwave at 70 W, or (3) RF at 200 W ( n = 7 each). CT and US images were obtained simultaneously at 1, 3, and 5 min during ablation and 2, 5, and 10 min post-ablation. Each ablation was sectioned in the plane of the ultrasound image and underwent vital staining to delineate cellular necrosis. CT was reformatted to the same plane as the ultrasound transducer and transverse diameters of gas and hypoechoic/hypoattenuating zones at each time point were measured. CT, ultrasound and gross pathologic diameter measurements were compared using Student's t -tests and linear regression. Results: Visible gas and the hypoechoic zone on US images were more predictive of the pathologic ablation zone than on NCCT images ( p < 0.05). The zone of necrosis was larger than the zone of visible gas on US (mean 3.2 mm for microwave, 6.4 mm for RF) and NCCT (7.6 mm microwave, 13.9 mm RF) images ( p < 0.05). The zone of visible gas and hypoechoic zone on US are more predictive of pathology with microwave ablations when compared with RF ablations ( p < 0.05). Conclusion: When evaluating images during energy delivery, US is more accurate than CT and microwave- moreAbstract: Purpose: The goal of this study was to compare intra-procedural radiofrequency (RF) and microwave ablation appearance on non-contrast CT (NCCT) and ultrasound to the zone of pathologic necrosis. Materials and methods: Twenty-one 5-min ablations were performed in vivo in swine liver with (1) microwave at 140 W, (2) microwave at 70 W, or (3) RF at 200 W ( n = 7 each). CT and US images were obtained simultaneously at 1, 3, and 5 min during ablation and 2, 5, and 10 min post-ablation. Each ablation was sectioned in the plane of the ultrasound image and underwent vital staining to delineate cellular necrosis. CT was reformatted to the same plane as the ultrasound transducer and transverse diameters of gas and hypoechoic/hypoattenuating zones at each time point were measured. CT, ultrasound and gross pathologic diameter measurements were compared using Student's t -tests and linear regression. Results: Visible gas and the hypoechoic zone on US images were more predictive of the pathologic ablation zone than on NCCT images ( p < 0.05). The zone of necrosis was larger than the zone of visible gas on US (mean 3.2 mm for microwave, 6.4 mm for RF) and NCCT (7.6 mm microwave, 13.9 mm RF) images ( p < 0.05). The zone of visible gas and hypoechoic zone on US are more predictive of pathology with microwave ablations when compared with RF ablations ( p < 0.05). Conclusion: When evaluating images during energy delivery, US is more accurate than CT and microwave- more predictable than RF-ablation based on correlation with in-plane pathology. … (more)
- Is Part Of:
- International journal of hyperthermia. Volume 37:Number 1(2020)
- Journal:
- International journal of hyperthermia
- Issue:
- Volume 37:Number 1(2020)
- Issue Display:
- Volume 37, Issue 1 (2020)
- Year:
- 2020
- Volume:
- 37
- Issue:
- 1
- Issue Sort Value:
- 2020-0037-0001-0000
- Page Start:
- 799
- Page End:
- 807
- Publication Date:
- 2020-01-01
- Subjects:
- Thermal ablation -- radiologic pathologic correlation -- radiofrequency -- microwave -- hepatic ablation
Thermotherapy -- Periodicals
615.832 - Journal URLs:
- http://informahealthcare.com/loi/hth ↗
http://www.tandf.co.uk/journals/titles/02656736.asp ↗
http://informahealthcare.com ↗ - DOI:
- 10.1080/02656736.2020.1784471 ↗
- Languages:
- English
- ISSNs:
- 0265-6736
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4542.297000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 22630.xml