Comparative pharmacokinetic analysis of levonorgestrel-releasing intrauterine systems and levonorgestrel-containing contraceptives with oral or subdermal administration route. (1st November 2020)
- Record Type:
- Journal Article
- Title:
- Comparative pharmacokinetic analysis of levonorgestrel-releasing intrauterine systems and levonorgestrel-containing contraceptives with oral or subdermal administration route. (1st November 2020)
- Main Title:
- Comparative pharmacokinetic analysis of levonorgestrel-releasing intrauterine systems and levonorgestrel-containing contraceptives with oral or subdermal administration route
- Authors:
- Hofmann, Birte Maria
Apter, Dan
Bitzer, Johannes
Reinecke, Isabel
Serrani, Marco
Höchel, Joachim
Merz, Martin - Abstract:
- Abstract: Objective: To compare systemic exposure to levonorgestrel (LNG) released from commercially available intrauterine systems (IUSs), a subdermal implant, and oral contraceptives. Methods: An integrated population pharmacokinetic (popPK) analysis of data from over 3400 individuals in ten clinical studies with six different LNG-releasing contraceptives (four long-acting reversible contraceptives [LARCs: LNG-IUS 8, 12, and 20, initially releasing LNG 14, 17.5, and 20 μg/day, a subdermal implant initially releasing LNG 100 μg/day according to label]; progestin-only pill [POP: LNG 30 μg/day]; and combined oral contraceptive [COC] pill [LNG 100 μg/day and ethinylestradiol 20 μg/day]), was conducted to generate a popPK model. LNG release rates, and total and unbound serum/plasma LNG concentrations with LARCs were estimated over the indicated period of use; maximum (Cmax ) and average (Cav ) serum LNG concentrations were estimated at steady state for oral contraceptives. Influence of body weight on LNG PK was also investigated. Results: Serum LNG concentration with LARCs increased with increasing daily LNG release rate, being lowest with LNG-IUS 8, higher with LNG-IUS 12 and LNG-IUS 20, and highest with the subdermal implant (1.7–2.1-times that with LNG-IUS 20). Compared with early serum LNG concentrations with LNG-IUS 20, Cav and Cmax were 1.7- and 4.5-fold higher with POP, and 8.6- and 18-fold higher with COC. Total LNG bioavailability was >97% for the LNG-IUSs and 66–80%Abstract: Objective: To compare systemic exposure to levonorgestrel (LNG) released from commercially available intrauterine systems (IUSs), a subdermal implant, and oral contraceptives. Methods: An integrated population pharmacokinetic (popPK) analysis of data from over 3400 individuals in ten clinical studies with six different LNG-releasing contraceptives (four long-acting reversible contraceptives [LARCs: LNG-IUS 8, 12, and 20, initially releasing LNG 14, 17.5, and 20 μg/day, a subdermal implant initially releasing LNG 100 μg/day according to label]; progestin-only pill [POP: LNG 30 μg/day]; and combined oral contraceptive [COC] pill [LNG 100 μg/day and ethinylestradiol 20 μg/day]), was conducted to generate a popPK model. LNG release rates, and total and unbound serum/plasma LNG concentrations with LARCs were estimated over the indicated period of use; maximum (Cmax ) and average (Cav ) serum LNG concentrations were estimated at steady state for oral contraceptives. Influence of body weight on LNG PK was also investigated. Results: Serum LNG concentration with LARCs increased with increasing daily LNG release rate, being lowest with LNG-IUS 8, higher with LNG-IUS 12 and LNG-IUS 20, and highest with the subdermal implant (1.7–2.1-times that with LNG-IUS 20). Compared with early serum LNG concentrations with LNG-IUS 20, Cav and Cmax were 1.7- and 4.5-fold higher with POP, and 8.6- and 18-fold higher with COC. Total LNG bioavailability was >97% for the LNG-IUSs and 66–80% with other contraceptives. Serum/plasma LNG concentrations decreased with increasing body weight. Conclusions: Among the contraceptives examined, COC had the highest and LNG-IUSs the lowest systemic exposure to LNG. Systemic LNG concentration was inversely correlated to body weight. … (more)
- Is Part Of:
- European journal of contraception & reproductive health care. Volume 25:Number 6(2020)
- Journal:
- European journal of contraception & reproductive health care
- Issue:
- Volume 25:Number 6(2020)
- Issue Display:
- Volume 25, Issue 6 (2020)
- Year:
- 2020
- Volume:
- 25
- Issue:
- 6
- Issue Sort Value:
- 2020-0025-0006-0000
- Page Start:
- 417
- Page End:
- 426
- Publication Date:
- 2020-11-01
- Subjects:
- Contraception -- levonorgestrel -- levonorgestrel-releasing contraceptive system -- pharmacokinetics
Contraception -- Periodicals
Reproductive health -- Periodicals
Generative organs, Female -- Periodicals
Contraception -- Periodicals
Reproductive Medicine -- Periodicals
613.9 - Journal URLs:
- http://informahealthcare.com/journal/ejc ↗
http://informahealthcare.com/loi/ejc/ ↗
http://www.tandf.co.uk/journals/titles/13625187.asp ↗
http://informahealthcare.com ↗ - DOI:
- 10.1080/13625187.2020.1815008 ↗
- Languages:
- English
- ISSNs:
- 1362-5187
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3829.728227
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 22648.xml