Paving the way for establishing a reference measurement system for standardization of plasma prothrombin time: Harmonizing the manual tilt tube method. (25th June 2020)
- Record Type:
- Journal Article
- Title:
- Paving the way for establishing a reference measurement system for standardization of plasma prothrombin time: Harmonizing the manual tilt tube method. (25th June 2020)
- Main Title:
- Paving the way for establishing a reference measurement system for standardization of plasma prothrombin time: Harmonizing the manual tilt tube method
- Authors:
- van den Besselaar, Antonius M. H. P.
van Rijn, Claudia J. J.
Abdoel, Charmane F.
Chantarangkul, Veena
Scalambrino, Erica
Kitchen, Steve
Tripodi, Armando
Woolley, Anita M.
Padovan, Lidia
Cobbaert, Christa M. - Abstract:
- Abstract: Background: International normalized ratio (INR) is traceable to World Health Organization (WHO) International Standards for thromboplastins. International Standards must be used with a manual tilt tube technique (MTT) for prothrombin time (PT) determination. An important part of the total variability of INR is due to poor harmonization of MTT across WHO reference laboratories. Objectives: To determine the origins of PT differences between operators performing MTT and to develop a harmonized MTT. Methods: Two workshops were held where WHO reference laboratory operators could compare their PTs using MTT and the same equipment. A harmonized MTT was used by seven operators in the second workshop. Results: Differences have been observed in tilting frequency and in the height of pipetting plasma in the test tube. At the beginning of the first workshop, the tilting cycle time varied between 1.1 and 2.7 seconds. The mean PT of normal plasma obtained by pipetting plasma at the top of the tube was 14.3 seconds but was 12.9 seconds when plasma was pipetted at the bottom of the tube. When using the harmonized MTT for WHO International Standard rTF/16, the differences between operators were not greater than 1.1 seconds in normal plasma, and not greater than 1.3 seconds in patient plasma with average INR of 3.0. INR between‐operator coefficient of variation was 2.3%. Conclusion: Application of a harmonized MTT in three reference laboratories resulted in substantial reduction ofAbstract: Background: International normalized ratio (INR) is traceable to World Health Organization (WHO) International Standards for thromboplastins. International Standards must be used with a manual tilt tube technique (MTT) for prothrombin time (PT) determination. An important part of the total variability of INR is due to poor harmonization of MTT across WHO reference laboratories. Objectives: To determine the origins of PT differences between operators performing MTT and to develop a harmonized MTT. Methods: Two workshops were held where WHO reference laboratory operators could compare their PTs using MTT and the same equipment. A harmonized MTT was used by seven operators in the second workshop. Results: Differences have been observed in tilting frequency and in the height of pipetting plasma in the test tube. At the beginning of the first workshop, the tilting cycle time varied between 1.1 and 2.7 seconds. The mean PT of normal plasma obtained by pipetting plasma at the top of the tube was 14.3 seconds but was 12.9 seconds when plasma was pipetted at the bottom of the tube. When using the harmonized MTT for WHO International Standard rTF/16, the differences between operators were not greater than 1.1 seconds in normal plasma, and not greater than 1.3 seconds in patient plasma with average INR of 3.0. INR between‐operator coefficient of variation was 2.3%. Conclusion: Application of a harmonized MTT in three reference laboratories resulted in substantial reduction of between‐operator variation of PT and INR. The harmonized MTT is proposed as Candidate Reference Measurement Procedure. … (more)
- Is Part Of:
- Journal of thrombosis and haemostasis. Volume 18:Number 8(2020)
- Journal:
- Journal of thrombosis and haemostasis
- Issue:
- Volume 18:Number 8(2020)
- Issue Display:
- Volume 18, Issue 8 (2020)
- Year:
- 2020
- Volume:
- 18
- Issue:
- 8
- Issue Sort Value:
- 2020-0018-0008-0000
- Page Start:
- 1986
- Page End:
- 1994
- Publication Date:
- 2020-06-25
- Subjects:
- international normalized ratio -- prothrombin time -- thromboplastin -- reference standards -- World Health Organization -- metrological traceability
Thrombosis -- Periodicals
Hemostasis -- Periodicals
Blood coagulation disorders -- Periodicals
616.1 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1538-7836 ↗
http://www.blackwellpublishing.com/journals/jth ↗
https://www.sciencedirect.com/journal/journal-of-thrombosis-and-haemostasis ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1111/jth.14873 ↗
- Languages:
- English
- ISSNs:
- 1538-7933
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5069.345000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 22616.xml