A Pre‐Release Algorithm With a Confidence Map for Estimating the Attenuation Coefficient for Liver Fat Quantification. (3rd November 2021)
- Record Type:
- Journal Article
- Title:
- A Pre‐Release Algorithm With a Confidence Map for Estimating the Attenuation Coefficient for Liver Fat Quantification. (3rd November 2021)
- Main Title:
- A Pre‐Release Algorithm With a Confidence Map for Estimating the Attenuation Coefficient for Liver Fat Quantification
- Authors:
- Barr, Richard G.
Cestone, Angelo
De Silvestri, Annalisa - Abstract:
- Abstract : Objectives: To compare the estimates of attenuation coefficient (AC) for liver fat quantification between 2 Ultrasound systems and to evaluate the quality measure of a pre‐released software. Methods: AC were obtained in 30 participants in this single‐center IRB‐approved, HIPAA compliant study. Images were obtained on the Philips Epiq Elite system using experimental software and the Canon Medical Systems Aplio i800 with released software. Five AC measurements were taken and the median and IQR/M were calculated. Region of interest placement was based on a confidence map. ROI was at the same depth and size for each system. The concordance was estimated using the Lin's concordance correlation coefficient (CCC), the r Pearson's correlation coefficient, the bias‐correction factor (Cb), and the Bland–Altman method. Results: The ACs varied from 0.45 to 1.0 dB/cm/MHz for the Philips system and 0.30 to 0.96 dB/cm/MHz for the Canon system. The CCC (95% CI) was 0.792 (0.666–0.918), Pearson's r was 0.839 with Cb of 0.944, and the mean difference was 0.03 (−0.101; 0.162) suggesting the 2 methods are considered to be in agreement. Based on a Philips confidence map to determine the best location for performing the measurements, a depth of 3.5 to 4.0 cm from the liver capsule was determined, which might be significantly different than that of the Canon system. Conclusions: Estimation of the AC of the 2 systems showed a high agreement, that is, a similar trend. Assessment of theAbstract : Objectives: To compare the estimates of attenuation coefficient (AC) for liver fat quantification between 2 Ultrasound systems and to evaluate the quality measure of a pre‐released software. Methods: AC were obtained in 30 participants in this single‐center IRB‐approved, HIPAA compliant study. Images were obtained on the Philips Epiq Elite system using experimental software and the Canon Medical Systems Aplio i800 with released software. Five AC measurements were taken and the median and IQR/M were calculated. Region of interest placement was based on a confidence map. ROI was at the same depth and size for each system. The concordance was estimated using the Lin's concordance correlation coefficient (CCC), the r Pearson's correlation coefficient, the bias‐correction factor (Cb), and the Bland–Altman method. Results: The ACs varied from 0.45 to 1.0 dB/cm/MHz for the Philips system and 0.30 to 0.96 dB/cm/MHz for the Canon system. The CCC (95% CI) was 0.792 (0.666–0.918), Pearson's r was 0.839 with Cb of 0.944, and the mean difference was 0.03 (−0.101; 0.162) suggesting the 2 methods are considered to be in agreement. Based on a Philips confidence map to determine the best location for performing the measurements, a depth of 3.5 to 4.0 cm from the liver capsule was determined, which might be significantly different than that of the Canon system. Conclusions: Estimation of the AC of the 2 systems showed a high agreement, that is, a similar trend. Assessment of the placement of the measurement box based on the quality of the measurement might be different between the 2 systems. … (more)
- Is Part Of:
- Journal of ultrasound in medicine. Volume 41:Number 8(2022)
- Journal:
- Journal of ultrasound in medicine
- Issue:
- Volume 41:Number 8(2022)
- Issue Display:
- Volume 41, Issue 8 (2022)
- Year:
- 2022
- Volume:
- 41
- Issue:
- 8
- Issue Sort Value:
- 2022-0041-0008-0000
- Page Start:
- 1939
- Page End:
- 1948
- Publication Date:
- 2021-11-03
- Subjects:
- attenuation coefficient -- attenuation imaging -- liver fat quantification -- NAFLD
Ultrasonics in medicine -- Periodicals
Ultrasonics
Ultrasonography
Ultrasonics in medicine
Electronic journals
Periodicals
Periodicals
616.07543 - Journal URLs:
- http://www.jultrasoundmed.org/ ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/jum.15870 ↗
- Languages:
- English
- ISSNs:
- 0278-4297
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5071.455000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 22596.xml