Use of a human wrist blood pressure monitor for arterial blood pressure measurements in normotensive conscious dogs in comparison to veterinary high‐definition oscillometry. Issue 4 (13th May 2022)
- Record Type:
- Journal Article
- Title:
- Use of a human wrist blood pressure monitor for arterial blood pressure measurements in normotensive conscious dogs in comparison to veterinary high‐definition oscillometry. Issue 4 (13th May 2022)
- Main Title:
- Use of a human wrist blood pressure monitor for arterial blood pressure measurements in normotensive conscious dogs in comparison to veterinary high‐definition oscillometry
- Authors:
- Martinelli, Elisa
Ferriani, Riccardo
Zanaboni, Annamaria
Toschi Corneliani, Roberto
Locatelli, Chiara - Abstract:
- Abstract: Background: The gold standard in canine blood pressure (BP) measurement is the invasive method; however, non‐invasive blood pressure measurement techniques (NIBP) are more commonly used. The lack of small, lightweight, cheap, fast and portable NIBP still remains a point to improve in the emergency setting. Key Findings: A human wrist blood pressure (WBP) device was evaluated in comparison with the veterinary high‐definition oscillometry (HDO) in conscious normotensive dogs. Systolic and diastolic BPs were evaluated in two groups of dogs. The bias, the limits of agreement and correlation between variables were calculated. Twenty‐five and 36 dogs were, respectively, included in Study No. 1 (dogs weighting ≥10 kg) and 2 (dogs weighting ≥20 kg). In both studies, correlation between the two devices was moderate. A better agreement was displayed for diastolic pressure and poor precision for both systolic and diastolic pressures measurements (as determined by wide limits of agreement). The WBP method underestimated both the systolic and diastolic BP with respect to the HDO method. The inclusion of bigger dogs (Study No. 2) with limb circumference more like to human limb dimension did not improve the agreement between considered methods. Significance: The human WBP monitor considered is not suitable to replace the commonly used veterinary HDO for in‐clinic BP monitoring in normotensive conscious dogs. Abstract : A human wrist blood pressure (WBP) device, cheap, small,Abstract: Background: The gold standard in canine blood pressure (BP) measurement is the invasive method; however, non‐invasive blood pressure measurement techniques (NIBP) are more commonly used. The lack of small, lightweight, cheap, fast and portable NIBP still remains a point to improve in the emergency setting. Key Findings: A human wrist blood pressure (WBP) device was evaluated in comparison with the veterinary high‐definition oscillometry (HDO) in conscious normotensive dogs. Systolic and diastolic BPs were evaluated in two groups of dogs. The bias, the limits of agreement and correlation between variables were calculated. Twenty‐five and 36 dogs were, respectively, included in Study No. 1 (dogs weighting ≥10 kg) and 2 (dogs weighting ≥20 kg). In both studies, correlation between the two devices was moderate. A better agreement was displayed for diastolic pressure and poor precision for both systolic and diastolic pressures measurements (as determined by wide limits of agreement). The WBP method underestimated both the systolic and diastolic BP with respect to the HDO method. The inclusion of bigger dogs (Study No. 2) with limb circumference more like to human limb dimension did not improve the agreement between considered methods. Significance: The human WBP monitor considered is not suitable to replace the commonly used veterinary HDO for in‐clinic BP monitoring in normotensive conscious dogs. Abstract : A human wrist blood pressure (WBP) device, cheap, small, lightweight, portable, easy to use and with an autonomous battery, was evaluated in comparison with the veterinary high‐definition oscillometry (HDO) in conscious normotensive dogs. The human WBP monitor considered is not suitable to replace the commonly used veterinary HDO for in‐clinic BP monitoring in normotensive conscious dogs. … (more)
- Is Part Of:
- Veterinary medicine and science. Volume 8:Issue 4(2022)
- Journal:
- Veterinary medicine and science
- Issue:
- Volume 8:Issue 4(2022)
- Issue Display:
- Volume 8, Issue 4 (2022)
- Year:
- 2022
- Volume:
- 8
- Issue:
- 4
- Issue Sort Value:
- 2022-0008-0004-0000
- Page Start:
- 1429
- Page End:
- 1433
- Publication Date:
- 2022-05-13
- Subjects:
- blood pressure -- high‐definition oscillometry -- normotensive dogs -- wrist blood pressure monitor
Veterinary medicine -- Periodicals
Animal Diseases
Veterinary medicine
Periodicals
Periodicals
636.08905 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)2053-1095 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/vms3.817 ↗
- Languages:
- English
- ISSNs:
- 2053-1095
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 22755.xml