A deep learning method for translating 3DCT to SPECT ventilation imaging: First comparison with 81mKr‐gas SPECT ventilation imaging. Issue 7 (17th May 2022)
- Record Type:
- Journal Article
- Title:
- A deep learning method for translating 3DCT to SPECT ventilation imaging: First comparison with 81mKr‐gas SPECT ventilation imaging. Issue 7 (17th May 2022)
- Main Title:
- A deep learning method for translating 3DCT to SPECT ventilation imaging: First comparison with 81mKr‐gas SPECT ventilation imaging
- Authors:
- Kajikawa, Tomohiro
Kadoya, Noriyuki
Maehara, Yosuke
Miura, Hiroshi
Katsuta, Yoshiyuki
Nagasawa, Shinsuke
Suzuki, Gen
Yamazaki, Hideya
Tamaki, Nagara
Yamada, Kei - Abstract:
- Abstract: Purpose: This study aimed to evaluate the accuracy of deep learning (DL)‐based computed tomography (CT) ventilation imaging (CTVI). Methods: A total of 71 cases that underwent single‐photon emission CT 81m Kr‐gas ventilation (SPECT V) and CT imaging were included. Sixty cases were assigned to the training and validation sets, and the remaining 11 cases were assigned to the test set. To directly transform three‐dimensional (3D) CT (free‐breathing CT) images to SPECT V images, a DL‐based model was implemented based on the U‐Net architecture. The input and output data were 3DCT‐ and SPECT V‐masked, respectively, except for whole‐lung volumes. These data were rearranged in voxel size, registered rigidly, cropped, and normalized in preprocessing. In addition to a standard estimation method (i.e., without dropout during the estimation process), a Monte Carlo dropout (MCD) method (i.e., with dropout during the estimation process) was used to calculate prediction uncertainty. To evaluate the two models' (CTVIMCD U‐Net, CTVIU‐Net ) performance, we used fivefold cross‐validation for the training and validation sets. To test the final model performances for both approaches, we applied the test set to each trained model and averaged the test prediction results from the five trained models to acquire the mean test result (bagging) for each approach. For the MCD method, the models were predicted repeatedly (sample size = 200), and the average and standard deviation (SD) mapsAbstract: Purpose: This study aimed to evaluate the accuracy of deep learning (DL)‐based computed tomography (CT) ventilation imaging (CTVI). Methods: A total of 71 cases that underwent single‐photon emission CT 81m Kr‐gas ventilation (SPECT V) and CT imaging were included. Sixty cases were assigned to the training and validation sets, and the remaining 11 cases were assigned to the test set. To directly transform three‐dimensional (3D) CT (free‐breathing CT) images to SPECT V images, a DL‐based model was implemented based on the U‐Net architecture. The input and output data were 3DCT‐ and SPECT V‐masked, respectively, except for whole‐lung volumes. These data were rearranged in voxel size, registered rigidly, cropped, and normalized in preprocessing. In addition to a standard estimation method (i.e., without dropout during the estimation process), a Monte Carlo dropout (MCD) method (i.e., with dropout during the estimation process) was used to calculate prediction uncertainty. To evaluate the two models' (CTVIMCD U‐Net, CTVIU‐Net ) performance, we used fivefold cross‐validation for the training and validation sets. To test the final model performances for both approaches, we applied the test set to each trained model and averaged the test prediction results from the five trained models to acquire the mean test result (bagging) for each approach. For the MCD method, the models were predicted repeatedly (sample size = 200), and the average and standard deviation (SD) maps were calculated in each voxel from the predicted results: The average maps were defined as test prediction results in each fold. As an evaluation index, the voxel‐wise Spearman rank correlation coefficient (Spearman r s ) and Dice similarity coefficient (DSC) were calculated. The DSC was calculated for three functional regions (high, moderate, and low) separated by an almost equal volume. The coefficient of variation was defined as prediction uncertainty, and these average values were calculated within three functional regions. The Wilcoxon signed‐rank test was used to test for a significant difference between the two DL‐based approaches. Results: The average indexes with one SD (1SD) between CTVIMCD U‐Net and SPECT V were 0.76 ± 0.06, 0.69 ± 0.07, 0.51 ± 0.06, and 0.75 ± 0.04 for Spearman r s, DSChigh, DSCmoderate, and DSClow, respectively. The average indexes with 1SD between CTVIU‐Net and SPECT V were 0.72 ± 0.05, 0.66 ± 0.04, 0.48 ± 0.04, and 0.74 ± 0.06 for Spearman r s, DSChigh, DSCmoderate, and DSClow, respectively. These indexes between CTVIMCD U‐Net and CTVIU‐Net showed no significance difference (Spearman r s, p = 0.175; DSChigh, p = 0.123; DSCmoderate, p = 0.278; DSClow, p = 0.520). The average coefficient of variations with 1SD were 0.27 ± 0.00, 0.27 ± 0.01, and 0.36 ± 0.03 for the high‐, moderate‐, and low‐functional regions, respectively, and the low‐functional region showed a tendency to exhibit larger uncertainties than the others. Conclusion: We evaluated DL‐based framework for estimating lung‐functional ventilation images only from CT images. The results indicated that the DL‐based approach could potentially be used for lung‐ventilation estimation. … (more)
- Is Part Of:
- Medical physics. Volume 49:Issue 7(2022)
- Journal:
- Medical physics
- Issue:
- Volume 49:Issue 7(2022)
- Issue Display:
- Volume 49, Issue 7 (2022)
- Year:
- 2022
- Volume:
- 49
- Issue:
- 7
- Issue Sort Value:
- 2022-0049-0007-0000
- Page Start:
- 4353
- Page End:
- 4364
- Publication Date:
- 2022-05-17
- Subjects:
- deep learning -- functional imaging -- radiotherapy
Medical physics -- Periodicals
Medical physics
Geneeskunde
Natuurkunde
Toepassingen
Biophysics
Periodicals
Periodicals
Electronic journals
610.153 - Journal URLs:
- http://scitation.aip.org/content/aapm/journal/medphys ↗
https://aapm.onlinelibrary.wiley.com/journal/24734209 ↗
http://www.aip.org/ ↗ - DOI:
- 10.1002/mp.15697 ↗
- Languages:
- English
- ISSNs:
- 0094-2405
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5531.130000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 22615.xml