Remote capillary blood collection for HbA1c measurement during the COVID‐19 pandemic: A laboratory and patient perspective. Issue 8 (19th June 2022)
- Record Type:
- Journal Article
- Title:
- Remote capillary blood collection for HbA1c measurement during the COVID‐19 pandemic: A laboratory and patient perspective. Issue 8 (19th June 2022)
- Main Title:
- Remote capillary blood collection for HbA1c measurement during the COVID‐19 pandemic: A laboratory and patient perspective
- Authors:
- Groenendijk, Wendy N.
Griffin, Tomás P.
Islam, Md N.
Blake, Liam
Wall, Deirdre
Bell, Marcia
O'Shea, Paula M. - Abstract:
- Abstract: Aims: The purpose of this study was to assess the clinical performance and user acceptance of capillary blood samples prepared remotely using the MiniCollect® capillary blood collection device as an alternative to blood collection by venepuncture for glycated haemoglobin (HbA1c ) analysis. Methods: Following written informed consent, a cross‐sectional study was conducted in individuals aged ≥18 years with any type of diabetes who routinely self‐monitor their blood glucose. Eligible participants recruited whilst attending their routine clinical appointments were required to provide a venous blood sample, prepare a capillary blood sample at home (remotely) and complete a bespoke questionnaire. HbA1c in whole blood collected in ethylenediaminetetraacetic acid was determined by capillary electrophoresis on the Sebia Capillary's 3 Tera analyser following standard operating procedure. Results: HbA1c results from both venous and capillary collection demonstrated good agreement. Passing‐Bablok regression: y = 0 + 1 x ( p = 0.18), Spearman correlation r = 0.986, p < 0.0001. The Bland–Altman difference plot provided a mean difference of 0.3 mmol/mol (2.2%). Over half of the participants found the MiniCollect device easy to use. The majority of participants were in favour of the remote capillary blood collection service and would use it if routinely available. Conclusion: The home collection of capillary blood for HbA1c determination is a valuable and convenientAbstract: Aims: The purpose of this study was to assess the clinical performance and user acceptance of capillary blood samples prepared remotely using the MiniCollect® capillary blood collection device as an alternative to blood collection by venepuncture for glycated haemoglobin (HbA1c ) analysis. Methods: Following written informed consent, a cross‐sectional study was conducted in individuals aged ≥18 years with any type of diabetes who routinely self‐monitor their blood glucose. Eligible participants recruited whilst attending their routine clinical appointments were required to provide a venous blood sample, prepare a capillary blood sample at home (remotely) and complete a bespoke questionnaire. HbA1c in whole blood collected in ethylenediaminetetraacetic acid was determined by capillary electrophoresis on the Sebia Capillary's 3 Tera analyser following standard operating procedure. Results: HbA1c results from both venous and capillary collection demonstrated good agreement. Passing‐Bablok regression: y = 0 + 1 x ( p = 0.18), Spearman correlation r = 0.986, p < 0.0001. The Bland–Altman difference plot provided a mean difference of 0.3 mmol/mol (2.2%). Over half of the participants found the MiniCollect device easy to use. The majority of participants were in favour of the remote capillary blood collection service and would use it if routinely available. Conclusion: The home collection of capillary blood for HbA1c determination is a valuable and convenient alternative to standard venous blood collection as it provides an opportunity to support routine HbA1c monitoring, whilst mitigating the transmission of SARS‐CoV‐2. This service would additionally allow individuals to attend clinic visits with a HbA1c value, ensuring optimal continuance of patient care for individuals with diabetes. … (more)
- Is Part Of:
- Diabetic medicine. Volume 39:Issue 8(2022)
- Journal:
- Diabetic medicine
- Issue:
- Volume 39:Issue 8(2022)
- Issue Display:
- Volume 39, Issue 8 (2022)
- Year:
- 2022
- Volume:
- 39
- Issue:
- 8
- Issue Sort Value:
- 2022-0039-0008-0000
- Page Start:
- n/a
- Page End:
- n/a
- Publication Date:
- 2022-06-19
- Subjects:
- capillary sampling -- delivery of care -- glycaemic control -- HbA1c -- remote monitoring
Diabetes -- Periodicals
616.462 - Journal URLs:
- http://www.blackwell-synergy.com/member/institutions/issuelist.asp?journal=dme ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1111/dme.14897 ↗
- Languages:
- English
- ISSNs:
- 0742-3071
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3579.606000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 22756.xml