Validity and Reliability of the Newly Developed Surface Electromyography Device for Measuring Muscle Activity during Voluntary Isometric Contraction. (29th August 2018)
- Record Type:
- Journal Article
- Title:
- Validity and Reliability of the Newly Developed Surface Electromyography Device for Measuring Muscle Activity during Voluntary Isometric Contraction. (29th August 2018)
- Main Title:
- Validity and Reliability of the Newly Developed Surface Electromyography Device for Measuring Muscle Activity during Voluntary Isometric Contraction
- Authors:
- Jang, Myung Hun
Ahn, Se Jin
Lee, Jun Woo
Rhee, Min-Hyung
Chae, Dasom
Kim, Jinmi
Shin, Myung Jun - Other Names:
- Togo Fumiharu Academic Editor.
- Abstract:
- Abstract : Objective . The purpose of this study was to establish the validity and reliability of the newly developed surface electromyography (sEMG) device (PSL-EMG-Tr1) compared with a conventional sEMG device (BTS-FREEEMG1000). Methods . In total, 20 healthy participants (10 males, age 30.3 ± 2.9 years; 10 females, age 22.3 ± 2.7 years) were recruited. EMG signals were recorded simultaneously on two devices during three different isometric contractions (maximal voluntary isometric contraction (MVIC, 40% MVIC, 80% MVIC)). Two trials were performed, and the same session was repeated after 1 week. EMG amplitude recorded from the dominant biceps brachii (BB) and rectus femoris (RF) muscles was analyzed for reliability using intrasession intraclass correlation coefficient (ICC). Concurrent validity of the two devices was determined using Pearson's correlation coefficient. Results . Nonnormalized sEMG data showed moderate to very high reliability for all three contraction levels (ICC = 0.832–0.937 (BB); ICC = 0.814–0.957 (RF)). Normalized sEMG values showed no to high reliability (ICC = 0.030–0.831 (BB); ICC = 0.547–0.828 (RF)). sEMG signals recorded by the PSL-EMG-Tr1 showed good to excellent validity compared with the BTS-FREEEMG1000, at 40% MVIC ( r = 0.943 (BB), r = 0.940 (RF)) and 80% MVIC ( r = 0.983 (BB); r = 0.763 (RF)). Conclusions . The PSL-EMG-Tr1 was performed with acceptable validity. Furthermore, the high accessibility and portability of the device are usefulAbstract : Objective . The purpose of this study was to establish the validity and reliability of the newly developed surface electromyography (sEMG) device (PSL-EMG-Tr1) compared with a conventional sEMG device (BTS-FREEEMG1000). Methods . In total, 20 healthy participants (10 males, age 30.3 ± 2.9 years; 10 females, age 22.3 ± 2.7 years) were recruited. EMG signals were recorded simultaneously on two devices during three different isometric contractions (maximal voluntary isometric contraction (MVIC, 40% MVIC, 80% MVIC)). Two trials were performed, and the same session was repeated after 1 week. EMG amplitude recorded from the dominant biceps brachii (BB) and rectus femoris (RF) muscles was analyzed for reliability using intrasession intraclass correlation coefficient (ICC). Concurrent validity of the two devices was determined using Pearson's correlation coefficient. Results . Nonnormalized sEMG data showed moderate to very high reliability for all three contraction levels (ICC = 0.832–0.937 (BB); ICC = 0.814–0.957 (RF)). Normalized sEMG values showed no to high reliability (ICC = 0.030–0.831 (BB); ICC = 0.547–0.828 (RF)). sEMG signals recorded by the PSL-EMG-Tr1 showed good to excellent validity compared with the BTS-FREEEMG1000, at 40% MVIC ( r = 0.943 (BB), r = 0.940 (RF)) and 80% MVIC ( r = 0.983 (BB); r = 0.763 (RF)). Conclusions . The PSL-EMG-Tr1 was performed with acceptable validity. Furthermore, the high accessibility and portability of the device are useful in adjusting the type and intensity of exercise. … (more)
- Is Part Of:
- Computational and mathematical methods in medicine. Volume 2018(2018)
- Journal:
- Computational and mathematical methods in medicine
- Issue:
- Volume 2018(2018)
- Issue Display:
- Volume 2018, Issue 2018 (2018)
- Year:
- 2018
- Volume:
- 2018
- Issue:
- 2018
- Issue Sort Value:
- 2018-2018-2018-0000
- Page Start:
- Page End:
- Publication Date:
- 2018-08-29
- Subjects:
- Medicine -- Computer simulation -- Periodicals
Medicine -- Mathematical models -- Periodicals
610.11 - Journal URLs:
- https://www.hindawi.com/journals/cmmm/ ↗
- DOI:
- 10.1155/2018/4068493 ↗
- Languages:
- English
- ISSNs:
- 1748-670X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3390.573000
British Library HMNTS - ELD Digital store - Ingest File:
- 22598.xml