Changes in levels of coagulation parameters in different trimesters among Chinese pregnant women. Issue 4 (5th February 2021)
- Record Type:
- Journal Article
- Title:
- Changes in levels of coagulation parameters in different trimesters among Chinese pregnant women. Issue 4 (5th February 2021)
- Main Title:
- Changes in levels of coagulation parameters in different trimesters among Chinese pregnant women
- Authors:
- Wang, Wengong
Long, Kai
Deng, Fenglin
Ye, Wei
Zhang, Pingwei
Chen, Xi
Dong, Weiguo
Zheng, Ping
Zhang, Xinxin
Yang, Tianyu
Chen, Weihong
Yang, Kai - Abstract:
- Abstract: Background: This article is to explore changes in levels of coagulation parameters in different trimesters among healthy pregnant women in China. Methods: A total of 760 eligible women were enrolled (first‐trimester group: n = 183, second‐trimester group: n = 183, third‐trimester group: n = 263, non‐pregnant group: n = 131). Seven parameters including prothrombin time (PT), activated partial thromboplastin time (APTT), thrombin time (TT), fibrinogen (FIB), D‐dimer (DD), fibrinogen degradation products (FDP), and antithrombin III (ATIII), of all participants were collected. The non‐parametric 2.5th–97.5th percentiles reference intervals were calculated for each parameter. Results: The reference intervals for FIB, PT, APTT, TT, FDP, DD, and ATIII at first trimester were 2.11–4.32 g/L, 10.90–13.85 s, 24.60–39.28 s, 12.95–15.88 s, 0.04–2.55 μg/mL, 0.03–1.15 μg/mL, and 75.57%‐125.31%, respectively. The reference intervals at second trimester were 2.31–4.77 g/L, 9.70–12.64 s, 24.16–35.43 s, 12.95–15.88 s, 0.15–7.40 μg/mL, 0.08–2.13 μg/mL, and 74.35%‐119.28%, respectively. For the third‐trimester, the intervals were 2.39–4.96 g/L, 9.20–11.95 s, 23.90–35.51 s, 13.41–18.00 s, 0.55–13.43 μg/mL, 0.15–3.60 μg/mL, and 71.61%‐118.29%, respectively. The third‐trimester group showed decreased PT, APTT, and ATIII and increased FIB, TT, DD and FDP as compared with the other groups. Conclusion: In this study, level changes of coagulation parameters in different trimesters wereAbstract: Background: This article is to explore changes in levels of coagulation parameters in different trimesters among healthy pregnant women in China. Methods: A total of 760 eligible women were enrolled (first‐trimester group: n = 183, second‐trimester group: n = 183, third‐trimester group: n = 263, non‐pregnant group: n = 131). Seven parameters including prothrombin time (PT), activated partial thromboplastin time (APTT), thrombin time (TT), fibrinogen (FIB), D‐dimer (DD), fibrinogen degradation products (FDP), and antithrombin III (ATIII), of all participants were collected. The non‐parametric 2.5th–97.5th percentiles reference intervals were calculated for each parameter. Results: The reference intervals for FIB, PT, APTT, TT, FDP, DD, and ATIII at first trimester were 2.11–4.32 g/L, 10.90–13.85 s, 24.60–39.28 s, 12.95–15.88 s, 0.04–2.55 μg/mL, 0.03–1.15 μg/mL, and 75.57%‐125.31%, respectively. The reference intervals at second trimester were 2.31–4.77 g/L, 9.70–12.64 s, 24.16–35.43 s, 12.95–15.88 s, 0.15–7.40 μg/mL, 0.08–2.13 μg/mL, and 74.35%‐119.28%, respectively. For the third‐trimester, the intervals were 2.39–4.96 g/L, 9.20–11.95 s, 23.90–35.51 s, 13.41–18.00 s, 0.55–13.43 μg/mL, 0.15–3.60 μg/mL, and 71.61%‐118.29%, respectively. The third‐trimester group showed decreased PT, APTT, and ATIII and increased FIB, TT, DD and FDP as compared with the other groups. Conclusion: In this study, level changes of coagulation parameters in different trimesters were observed. And the ranges for coagulation parameters were presented, which may provide some reference for clinicians to more accurately monitor the coagulation and fibrinolytic system in pregnant women. Abstract : In this study, level changes of coagulation parameters in different trimesters in Chinese pregnant women were observed. And the ranges for coagulation parameters were presented, which may provide some reference for clinicians to more accurately monitor the coagulation and fibrinolytic system in pregnant women. … (more)
- Is Part Of:
- Journal of clinical laboratory analysis. Volume 35:Issue 4(2021)
- Journal:
- Journal of clinical laboratory analysis
- Issue:
- Volume 35:Issue 4(2021)
- Issue Display:
- Volume 35, Issue 4 (2021)
- Year:
- 2021
- Volume:
- 35
- Issue:
- 4
- Issue Sort Value:
- 2021-0035-0004-0000
- Page Start:
- n/a
- Page End:
- n/a
- Publication Date:
- 2021-02-05
- Subjects:
- Chinese pregnant women -- coagulation parameters -- reference intervals
Diagnosis, Laboratory -- Periodicals
Medical laboratory technology -- Periodicals
616 - Journal URLs:
- http://onlinelibrary.wiley.com/ ↗
- DOI:
- 10.1002/jcla.23724 ↗
- Languages:
- English
- ISSNs:
- 0887-8013
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4958.520000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 22612.xml