Lead complications after cardiac surgery in patients with cardiac implantable electronic devices. (26th May 2022)
- Record Type:
- Journal Article
- Title:
- Lead complications after cardiac surgery in patients with cardiac implantable electronic devices. (26th May 2022)
- Main Title:
- Lead complications after cardiac surgery in patients with cardiac implantable electronic devices
- Authors:
- Frausing, Maria Hee Jung Park
Nielsen, Jens Cosedis
Johansen, Jens Brock
Jørgensen, Ole Dan
Kristensen, Jens
Olsen, Thomas
Gerdes, Christian
Kronborg, Mads Brix - Abstract:
- Abstract: OBJECTIVES: Manipulation of the heart during cardiac surgery in patients with cardiac implantable electronic devices (CIEDs) may result in lead damage or displacement, but whether cardiac surgery truly infers an excess risk of lead failure is not known. The objective of this study was to examine the risk of lead complications after cardiac surgery in patients with CIEDs. METHODS: We conducted a nationwide nested case–control study. The source population comprised all Danish patients ≥18 of age who underwent a de novo CIED implantation during 1998–2017. For inclusion, patients had to be alive and event free 6 months after implantation. Cases were matched 1:30 to controls on time, age, sex, and device type using risk set sampling. We used conditional logistic regression to estimate incidence rate ratios (IRRs) for the association between cardiac surgery and lead-related reoperation. RESULTS: Our final population consisted of 67 621 patients. We identified 1437 (2.1%) incident cases of lead-related reoperations and 42 698 controls. Risk of lead complications was highest within 6 months of cardiac surgery [IRR 9.7, 95% confidence interval (CI) 6.3–14.8, adjusted IRR 9.6, 95% CI 6.2–14.7], and at 1 year, the relative risk of lead-related reoperation was close to unity (adjusted IRR 1.2, 95% CI 0.8–1.7). CONCLUSIONS: Cardiac surgery was associated with a considerable risk of lead complications in patients with de novo CIEDs. Abstract : An improved understanding of theAbstract: OBJECTIVES: Manipulation of the heart during cardiac surgery in patients with cardiac implantable electronic devices (CIEDs) may result in lead damage or displacement, but whether cardiac surgery truly infers an excess risk of lead failure is not known. The objective of this study was to examine the risk of lead complications after cardiac surgery in patients with CIEDs. METHODS: We conducted a nationwide nested case–control study. The source population comprised all Danish patients ≥18 of age who underwent a de novo CIED implantation during 1998–2017. For inclusion, patients had to be alive and event free 6 months after implantation. Cases were matched 1:30 to controls on time, age, sex, and device type using risk set sampling. We used conditional logistic regression to estimate incidence rate ratios (IRRs) for the association between cardiac surgery and lead-related reoperation. RESULTS: Our final population consisted of 67 621 patients. We identified 1437 (2.1%) incident cases of lead-related reoperations and 42 698 controls. Risk of lead complications was highest within 6 months of cardiac surgery [IRR 9.7, 95% confidence interval (CI) 6.3–14.8, adjusted IRR 9.6, 95% CI 6.2–14.7], and at 1 year, the relative risk of lead-related reoperation was close to unity (adjusted IRR 1.2, 95% CI 0.8–1.7). CONCLUSIONS: Cardiac surgery was associated with a considerable risk of lead complications in patients with de novo CIEDs. Abstract : An improved understanding of the pathogenic mechanisms underlying cardiac arrhythmias and concurrent evolving technologies have expanded indications for cardiac implantable electronic device (CIED) therapy over the past decades [1]. … (more)
- Is Part Of:
- European journal of cardio-thoracic surgery. Volume 62:Number 2(2022)
- Journal:
- European journal of cardio-thoracic surgery
- Issue:
- Volume 62:Number 2(2022)
- Issue Display:
- Volume 62, Issue 2 (2022)
- Year:
- 2022
- Volume:
- 62
- Issue:
- 2
- Issue Sort Value:
- 2022-0062-0002-0000
- Page Start:
- Page End:
- Publication Date:
- 2022-05-26
- Subjects:
- Cardiac implantable electronic device -- Cardiac surgery -- Coronary artery bypass graft -- Heart valve surgery -- Complications -- Pacemaker -- Implantable cardioverter defibrillator
Heart -- Surgery -- Periodicals
Chest -- Surgery -- Periodicals
617.54 - Journal URLs:
- http://ejcts.oxfordjournals.org/ ↗
http://www.sciencedirect.com/science/journal/10107940 ↗
http://ukcatalogue.oup.com/ ↗ - DOI:
- 10.1093/ejcts/ezac318 ↗
- Languages:
- English
- ISSNs:
- 1010-7940
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3829.725620
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 22586.xml