RefineNet‐based 2D and 3D automatic segmentations for clinical target volume and organs at risks for patients with cervical cancer in postoperative radiotherapy. Issue 7 (9th May 2022)
- Record Type:
- Journal Article
- Title:
- RefineNet‐based 2D and 3D automatic segmentations for clinical target volume and organs at risks for patients with cervical cancer in postoperative radiotherapy. Issue 7 (9th May 2022)
- Main Title:
- RefineNet‐based 2D and 3D automatic segmentations for clinical target volume and organs at risks for patients with cervical cancer in postoperative radiotherapy
- Authors:
- Xiao, Chengjian
Jin, Juebin
Yi, Jinling
Han, Ce
Zhou, Yongqiang
Ai, Yao
Xie, Congying
Jin, Xiance - Abstract:
- Abstract: Purpose: An accurate and reliable target volume delineation is critical for the safe and successful radiotherapy. The purpose of this study is to develop new 2D and 3D automatic segmentation models based on RefineNet for clinical target volume (CTV) and organs at risk (OARs) for postoperative cervical cancer based on computed tomography (CT) images. Methods: A 2D RefineNet and 3D RefineNetPlus3D were adapted and built to automatically segment CTVs and OARs on a total of 44 222 CT slices of 313 patients with stage I–III cervical cancer. Fully convolutional networks (FCNs), U‐Net, context encoder network (CE‐Net), UNet3D, and ResUNet3D were also trained and tested with randomly divided training and validation sets, respectively. The performances of these automatic segmentation models were evaluated by Dice similarity coefficient (DSC), Jaccard similarity coefficient, and average symmetric surface distance when comparing them with manual segmentations with the test data. Results: The DSC for RefineNet, FCN, U‐Net, CE‐Net, UNet3D, ResUNet3D, and RefineNet3D were 0.82, 0.80, 0.82, 0.81, 0.80, 0.81, and 0.82 with a mean contouring time of 3.2, 3.4, 8.2, 3.9, 9.8, 11.4, and 6.4 s, respectively. The generated RefineNetPlus3D demonstrated a good performance in the automatic segmentation of bladder, small intestine, rectum, right and left femoral heads with a DSC of 0.97, 0.95, 091, 0.98, and 0.98, respectively, with a mean computation time of 6.6 s. Conclusions: The newlyAbstract: Purpose: An accurate and reliable target volume delineation is critical for the safe and successful radiotherapy. The purpose of this study is to develop new 2D and 3D automatic segmentation models based on RefineNet for clinical target volume (CTV) and organs at risk (OARs) for postoperative cervical cancer based on computed tomography (CT) images. Methods: A 2D RefineNet and 3D RefineNetPlus3D were adapted and built to automatically segment CTVs and OARs on a total of 44 222 CT slices of 313 patients with stage I–III cervical cancer. Fully convolutional networks (FCNs), U‐Net, context encoder network (CE‐Net), UNet3D, and ResUNet3D were also trained and tested with randomly divided training and validation sets, respectively. The performances of these automatic segmentation models were evaluated by Dice similarity coefficient (DSC), Jaccard similarity coefficient, and average symmetric surface distance when comparing them with manual segmentations with the test data. Results: The DSC for RefineNet, FCN, U‐Net, CE‐Net, UNet3D, ResUNet3D, and RefineNet3D were 0.82, 0.80, 0.82, 0.81, 0.80, 0.81, and 0.82 with a mean contouring time of 3.2, 3.4, 8.2, 3.9, 9.8, 11.4, and 6.4 s, respectively. The generated RefineNetPlus3D demonstrated a good performance in the automatic segmentation of bladder, small intestine, rectum, right and left femoral heads with a DSC of 0.97, 0.95, 091, 0.98, and 0.98, respectively, with a mean computation time of 6.6 s. Conclusions: The newly adapted RefineNet and developed RefineNetPlus3D were promising automatic segmentation models with accurate and clinically acceptable CTV and OARs for cervical cancer patients in postoperative radiotherapy. … (more)
- Is Part Of:
- Journal of applied clinical medical physics. Volume 23:Issue 7(2022)
- Journal:
- Journal of applied clinical medical physics
- Issue:
- Volume 23:Issue 7(2022)
- Issue Display:
- Volume 23, Issue 7 (2022)
- Year:
- 2022
- Volume:
- 23
- Issue:
- 7
- Issue Sort Value:
- 2022-0023-0007-0000
- Page Start:
- n/a
- Page End:
- n/a
- Publication Date:
- 2022-05-09
- Subjects:
- automatic segmentation -- cervical cancer -- clinical target volume -- deep learning -- organs at risk
Medical physics -- Periodicals
Clinical medicine -- Periodicals
Health Physics
Clinical Medicine
Electronic journals
Periodicals
Periodicals
Fulltext
Internet Resources
610.153 - Journal URLs:
- http://aapm.onlinelibrary.wiley.com/hub/journal/10.1002/(ISSN)1526-9914/ ↗
http://bibpurl.oclc.org/web/7294 ↗
http://www.jacmp.org/ ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/acm2.13631 ↗
- Languages:
- English
- ISSNs:
- 1526-9914
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 22564.xml