Calibration and standardization of extracellular vesicle measurements by flow cytometry for translational prostate cancer research. Issue 27 (30th June 2022)
- Record Type:
- Journal Article
- Title:
- Calibration and standardization of extracellular vesicle measurements by flow cytometry for translational prostate cancer research. Issue 27 (30th June 2022)
- Main Title:
- Calibration and standardization of extracellular vesicle measurements by flow cytometry for translational prostate cancer research
- Authors:
- Kim, Yohan
van der Pol, Edwin
Arafa, Ali
Thapa, Ishwor
J. Britton, Cameron
Kosti, Jorgena
Song, Siyang
Joshi, Vidhu B.
M. Erickson, Ree
Ali, Hesham
Lucien, Fabrice - Abstract:
- Abstract : Higher levels of tumor-derived extracellular vesicles are detected in metastatic prostate cancer compared to localized prostate cancer by standardized and calibrated flow cytometry. Abstract : Extracellular vesicles (EVs) are microscopic particles released naturally in biofluids by all cell types. Since EVs inherits genomic and proteomic patterns from the cell of origin, they are emerging as promising liquid biomarkers for human diseases. Flow cytometry is a popular method that is able to detect, characterize and determine the concentration of EVs with minimal sample preparation. However, the limited awareness of the scientific community to utilize standardization and calibration methods of flow cytometers is an important roadblock for data reproducibility and inter-laboratory comparison. A significant collaborative effort by the Extracellular Vesicle Flow Cytometry Working Group has led to the development of guidelines and best practices for using flow cytometry and reporting data in a way to improve rigor and reproducibility in EV research. At first look, standardization and calibration of flow cytometry for EV detection may seem burdensome and technically challenging for non-academic laboratories with limited technical training and knowledge in EV flow cytometry. In this study, we build on prior research efforts and provide a systematic approach to evaluate the performance of a high sensitivity flow cytometer (herein Apogee A60-Micro Plus) and fine-tuneAbstract : Higher levels of tumor-derived extracellular vesicles are detected in metastatic prostate cancer compared to localized prostate cancer by standardized and calibrated flow cytometry. Abstract : Extracellular vesicles (EVs) are microscopic particles released naturally in biofluids by all cell types. Since EVs inherits genomic and proteomic patterns from the cell of origin, they are emerging as promising liquid biomarkers for human diseases. Flow cytometry is a popular method that is able to detect, characterize and determine the concentration of EVs with minimal sample preparation. However, the limited awareness of the scientific community to utilize standardization and calibration methods of flow cytometers is an important roadblock for data reproducibility and inter-laboratory comparison. A significant collaborative effort by the Extracellular Vesicle Flow Cytometry Working Group has led to the development of guidelines and best practices for using flow cytometry and reporting data in a way to improve rigor and reproducibility in EV research. At first look, standardization and calibration of flow cytometry for EV detection may seem burdensome and technically challenging for non-academic laboratories with limited technical training and knowledge in EV flow cytometry. In this study, we build on prior research efforts and provide a systematic approach to evaluate the performance of a high sensitivity flow cytometer (herein Apogee A60-Micro Plus) and fine-tune settings to improve detection sensitivity for EVs. We performed calibration of our flow cytometer to generate data with comparable units (nanometers, MESF). Finally, we applied our optimized protocol to measure the concentrations of prostate-derived EVs in healthy individuals and prostate cancer patients. In conclusion, our proof-of-feasibility study can serve as a scientific and technical framework for other groups motivated in using flow cytometry for EV research. … (more)
- Is Part Of:
- Nanoscale. Volume 14:Issue 27(2022)
- Journal:
- Nanoscale
- Issue:
- Volume 14:Issue 27(2022)
- Issue Display:
- Volume 14, Issue 27 (2022)
- Year:
- 2022
- Volume:
- 14
- Issue:
- 27
- Issue Sort Value:
- 2022-0014-0027-0000
- Page Start:
- 9781
- Page End:
- 9795
- Publication Date:
- 2022-06-30
- Subjects:
- Nanoscience -- Periodicals
Nanotechnology -- Periodicals
620.505 - Journal URLs:
- http://www.rsc.org/Publishing/Journals/NR/Index.asp ↗
http://www.rsc.org/ ↗ - DOI:
- 10.1039/d2nr01160c ↗
- Languages:
- English
- ISSNs:
- 2040-3364
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 9830.266000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 22542.xml