Deneke, Thomas - Abstract:
- Abstract: Aims: Pulmonary vein isolation (PVI) using radiofrequency (RF) ablation is an effective treatment option for patients with atrial fibrillation (AF). This study aims to investigate the safety of high-power short duration (HPSD) with emphasis on oesophageal lesions after PVI. Methods and results: Consecutive patients undergoing AF ablation with HPSD (50 W; ablation index (AI)-guided; target AI 350 for posterior wall ablation, AI 450 for anterior wall ablation) using the ThermoCool SmartTouch SF catheter were included. Patients underwent post-ablation oesophageal endoscopy to detect and categorize thermal oesophageal injury (EDEL). Occurrence and risk factors of oesophageal lesions and perforating complications were analysed. A total of 1033 patients underwent AF ablation with HPSD. Of them, 953 patients (67.6 ± 9.6 years; 58% male; 43% paroxysmal AF; 68% first PVI) underwent post-procedural oesophageal endoscopy and were included in further analyses. Median procedure time was 82.8 ± 24.4 min with ablation times of 16.1 ± 9.2 min. Thermal oesophageal injury was detected in 58 patients (6%) ( n = 29 Category 1 erosion, n = 29 Category 2 ulcerous). One patient developed oesophageal perforation (redo, 4th AF ablation). No patient died. Using multivariable regression models, increased total ablation time [odds ratio (OR) 1.029, P = 0.010] and history of stroke (OR 2.619, P = 0.033) were associated with increased incidence of EDEL after AF ablation, whereas increased bodyAbstract: Aims: Pulmonary vein isolation (PVI) using radiofrequency (RF) ablation is an effective treatment option for patients with atrial fibrillation (AF). This study aims to investigate the safety of high-power short duration (HPSD) with emphasis on oesophageal lesions after PVI. Methods and results: Consecutive patients undergoing AF ablation with HPSD (50 W; ablation index (AI)-guided; target AI 350 for posterior wall ablation, AI 450 for anterior wall ablation) using the ThermoCool SmartTouch SF catheter were included. Patients underwent post-ablation oesophageal endoscopy to detect and categorize thermal oesophageal injury (EDEL). Occurrence and risk factors of oesophageal lesions and perforating complications were analysed. A total of 1033 patients underwent AF ablation with HPSD. Of them, 953 patients (67.6 ± 9.6 years; 58% male; 43% paroxysmal AF; 68% first PVI) underwent post-procedural oesophageal endoscopy and were included in further analyses. Median procedure time was 82.8 ± 24.4 min with ablation times of 16.1 ± 9.2 min. Thermal oesophageal injury was detected in 58 patients (6%) ( n = 29 Category 1 erosion, n = 29 Category 2 ulcerous). One patient developed oesophageal perforation (redo, 4th AF ablation). No patient died. Using multivariable regression models, increased total ablation time [odds ratio (OR) 1.029, P = 0.010] and history of stroke (OR 2.619, P = 0.033) were associated with increased incidence of EDEL after AF ablation, whereas increased body mass index was protective (OR 0.980, P = 0.022). Conclusion: Thermal oesophageal lesions occur in 6% of HPSD AF ablations. The risk for development of perforating complications seems to be low. Incidence of atrio-oesophageal fistula (0.1%) is comparable to other reported series about RF ablation approaches. … (more)
- Is Part Of:
- Europace. Volume 24:Issue 6(2022)
- Journal:
- Europace
- Issue:
- Volume 24:Issue 6(2022)
- Issue Display:
- Volume 24, Issue 6 (2022)
- Year:
- 2022
- Volume:
- 24
- Issue:
- 6
- Issue Sort Value:
- 2022-0024-0006-0000
- Page Start:
- 928
- Page End:
- 937
- Publication Date:
- 2022-02-02
- Subjects:
- Atrial fibrillation -- Pulmonary vein isolation -- High-power short duration ablation -- Prognosis -- Endoscopically detected oesophageal lesion
Arrhythmia -- Treatment -- Periodicals
Cardiac pacing -- Periodicals
Catheter ablation -- Periodicals
Heart -- Physiology -- Periodicals
Electrophysiology -- Periodicals
617.4120645 - Journal URLs:
- http://europace.oxfordjournals.org/ ↗
http://ukcatalogue.oup.com/ ↗ - DOI:
- 10.1093/europace/euab329 ↗
- Languages:
- English
- ISSNs:
- 1099-5129
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3829.340450
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 22551.xml