Agreement and accuracy of shear-wave techniques (point shear-wave elastography and 2D-shear-wave elastography) using transient elastography as reference. Issue 8 (29th June 2022)
- Record Type:
- Journal Article
- Title:
- Agreement and accuracy of shear-wave techniques (point shear-wave elastography and 2D-shear-wave elastography) using transient elastography as reference. Issue 8 (29th June 2022)
- Main Title:
- Agreement and accuracy of shear-wave techniques (point shear-wave elastography and 2D-shear-wave elastography) using transient elastography as reference
- Authors:
- Fernandes, Flavia
Piedade, Juliana
Freitas, Gabriela
Area, Philippe
Santos, Ricardo
Grinsztejn, Beatriz
Veloso, Valdilea
Pereira, Gustavo
Perazzo, Hugo - Abstract:
- Abstract : Objective: We aimed to evaluate the agreement/accuracy of point shear-wave elastography (p-SWE) and 2D-shear-wave elastography (2D-SWE) for liver fibrosis staging using transient elastography (TE) as the reference. Methods: This retrospective study analyzed data from people with chronic liver diseases submitted to TE, p-SWE, and 2D-SWE. Liver fibrosis stages were defined using the TE's 'rule of five': normal (<5 kPa); suggestive of compensated-advanced chronic liver disease (cACLD) (10–15 kPa); highly suggestive of cACLD (15–20 kPa); suggestive of clinically significant portal hypertension (>20 kPa). Agreement and accuracy of p-SWE and 2D-SWE were assessed. Optimal cutoffs for p-SWE and 2D-SWE were identified using the point nearest to the upper left corner of the ROC curves. Results: A total of 289 participants were included. The correlation between TE and 2D-SWE (rho = 0.59; P < 0.001) or p-SWE (rho = 0.69; P < 0.001) was satisfactory. The AUROCs (95% CI) of 2D-SWE and p-SWE for TE ≥ 5 kPa; TE ≥ 10 kPa; TE ≥ 15 kPa and TE ≥ 20 kPa were 0.757 (0.685–0.829) and 0.741 (0.676–0.806); 0.819 (0.770–0.868) and 0.870 (0.825–0.915); 0.848 (0.803–0.893) and 0.952 (0.927–0.978); 0.851 (0.806–0.896) and 0.951 (0.920–0.982), respectively. AUROCs of 2D-SWE were significantly lower compared with p-SWE for detecting cACLD. Optimal thresholds of 2D-SWE and p-SWE for TE ≥ 15 kPa were 8.82 kPa (sensitivity = 86% and specificity = 79%) and 8.86 kPa (sensitivity = 90% andAbstract : Objective: We aimed to evaluate the agreement/accuracy of point shear-wave elastography (p-SWE) and 2D-shear-wave elastography (2D-SWE) for liver fibrosis staging using transient elastography (TE) as the reference. Methods: This retrospective study analyzed data from people with chronic liver diseases submitted to TE, p-SWE, and 2D-SWE. Liver fibrosis stages were defined using the TE's 'rule of five': normal (<5 kPa); suggestive of compensated-advanced chronic liver disease (cACLD) (10–15 kPa); highly suggestive of cACLD (15–20 kPa); suggestive of clinically significant portal hypertension (>20 kPa). Agreement and accuracy of p-SWE and 2D-SWE were assessed. Optimal cutoffs for p-SWE and 2D-SWE were identified using the point nearest to the upper left corner of the ROC curves. Results: A total of 289 participants were included. The correlation between TE and 2D-SWE (rho = 0.59; P < 0.001) or p-SWE (rho = 0.69; P < 0.001) was satisfactory. The AUROCs (95% CI) of 2D-SWE and p-SWE for TE ≥ 5 kPa; TE ≥ 10 kPa; TE ≥ 15 kPa and TE ≥ 20 kPa were 0.757 (0.685–0.829) and 0.741 (0.676–0.806); 0.819 (0.770–0.868) and 0.870 (0.825–0.915); 0.848 (0.803–0.893) and 0.952 (0.927–0.978); 0.851 (0.806–0.896) and 0.951 (0.920–0.982), respectively. AUROCs of 2D-SWE were significantly lower compared with p-SWE for detecting cACLD. Optimal thresholds of 2D-SWE and p-SWE for TE ≥ 15 kPa were 8.82 kPa (sensitivity = 86% and specificity = 79%) and 8.86 kPa (sensitivity = 90% and specificity = 92%), respectively. Conclusion: LSM by p-SWE and 2D-SWE techniques were correlated with TE. LSM by p-SWE seems to be more accurate than 2D-SWE to identify patients with more advanced fibrosis. … (more)
- Is Part Of:
- European journal of gastroenterology & hepatology. Volume 34:Issue 8(2022)
- Journal:
- European journal of gastroenterology & hepatology
- Issue:
- Volume 34:Issue 8(2022)
- Issue Display:
- Volume 34, Issue 8 (2022)
- Year:
- 2022
- Volume:
- 34
- Issue:
- 8
- Issue Sort Value:
- 2022-0034-0008-0000
- Page Start:
- 873
- Page End:
- 881
- Publication Date:
- 2022-06-29
- Subjects:
- accuracy -- acoustic radiation force impulse -- liver stiffness -- shear-wave elastography -- transient elastography
Digestive organs -- Diseases -- Periodicals
Liver -- Diseases -- Periodicals
Digestive organs -- Diseases
Liver -- Diseases
Periodicals
616.33 - Journal URLs:
- http://ovidsp.ovid.com/ovidweb.cgi?T=JS&NEWS=n&CSC=Y&PAGE=toc&D=yrovft&AN=00042737-000000000-00000 ↗
http://www.eurojgh.com/ ↗
http://journals.lww.com/pages/default.aspx ↗ - DOI:
- 10.1097/MEG.0000000000002400 ↗
- Languages:
- English
- ISSNs:
- 0954-691X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3829.729400
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 22557.xml