Spirometer-guided breath-hold breast VMAT verified with portal images and surface tracking. (April 2021)
- Record Type:
- Journal Article
- Title:
- Spirometer-guided breath-hold breast VMAT verified with portal images and surface tracking. (April 2021)
- Main Title:
- Spirometer-guided breath-hold breast VMAT verified with portal images and surface tracking
- Authors:
- Delombaerde, Laurence
Petillion, Saskia
Weltens, Caroline
Depuydt, Tom - Abstract:
- Highlights: Spirometer breath-hold VMAT-SIB breast treatments on Halcyon can be performed in 10 min. Intra-bore surface scanning provides continuous monitoring of breath-hold performance. Portal images should be interpreted with caution due to MLC leaf occlusion. Abstract: Background and purpose: Fast rotating closed-bore gantry linacs are ideally suited for breath-hold treatments due to reduced imaging and delivery times. We evaluated the reproducibility and stability of spirometer-guided breath-hold breast treatments, using intra-bore surface monitoring and portal imaging on Halcyon (Varian Medical Systems). Materials and methods: Seven left-sided breast cancer patients were treated in breath-hold using the SDX spirometer (Dyn'R) with an integrated boost volumetric arc protocol on Halcyon. A dual depth-camera surface scanning system monitored the left breast. The interfraction, intrafraction and intrabreath-hold motion was determined in the anterior-posterior (AP) and superior-inferior (SI) direction. Portal images (PI), acquired at a tangential gantry angle were manually registered to the planning-CT to determine inter- and intrafraction breath-hold errors for the SI and tangential-anterior-posterior ("AP") axis. Correlations between PI and surface imaging deviations were investigated. To evaluate workflow efficiency, the total time and the number of breath-holds were recorded. Results: Systematic and random variability of breath-hold amplitude was below 0.7 mm for the APHighlights: Spirometer breath-hold VMAT-SIB breast treatments on Halcyon can be performed in 10 min. Intra-bore surface scanning provides continuous monitoring of breath-hold performance. Portal images should be interpreted with caution due to MLC leaf occlusion. Abstract: Background and purpose: Fast rotating closed-bore gantry linacs are ideally suited for breath-hold treatments due to reduced imaging and delivery times. We evaluated the reproducibility and stability of spirometer-guided breath-hold breast treatments, using intra-bore surface monitoring and portal imaging on Halcyon (Varian Medical Systems). Materials and methods: Seven left-sided breast cancer patients were treated in breath-hold using the SDX spirometer (Dyn'R) with an integrated boost volumetric arc protocol on Halcyon. A dual depth-camera surface scanning system monitored the left breast. The interfraction, intrafraction and intrabreath-hold motion was determined in the anterior-posterior (AP) and superior-inferior (SI) direction. Portal images (PI), acquired at a tangential gantry angle were manually registered to the planning-CT to determine inter- and intrafraction breath-hold errors for the SI and tangential-anterior-posterior ("AP") axis. Correlations between PI and surface imaging deviations were investigated. To evaluate workflow efficiency, the total time and the number of breath-holds were recorded. Results: Systematic and random variability of breath-hold amplitude was below 0.7 mm for the AP and below 1.2 mm for the SI component as detected by surface monitoring ( N = 130). Systematic and random errors retrieved from portal images ( N = 140) were below 1.2 mm for the "AP" and 2.1 mm for SI axis. A limited correlation was found between PI and surface monitoring deviations for both the SI and "AP" axes (R 2 = 0.27/0.38, p < 0.01). 75% of fractions were completed using four breath-holds and 82% within 10 min. Conclusion: Surface imaging indicated spirometer-guided breath-hold VMAT breast radiotherapy can be accurately and quickly performed on a closed-bore gantry linac. Intra-bore surface scanning proved a valuable technique for monitoring breathing motion in closed-bore systems. … (more)
- Is Part Of:
- Radiotherapy and oncology. Volume 157(2021)
- Journal:
- Radiotherapy and oncology
- Issue:
- Volume 157(2021)
- Issue Display:
- Volume 157, Issue 2021 (2021)
- Year:
- 2021
- Volume:
- 157
- Issue:
- 2021
- Issue Sort Value:
- 2021-0157-2021-0000
- Page Start:
- 78
- Page End:
- 84
- Publication Date:
- 2021-04
- Subjects:
- Oncology -- Periodicals
Radiotherapy -- Periodicals
Tumors -- Periodicals
Medical Oncology -- Periodicals
Neoplasms -- radiotherapy -- Periodicals
Radiotherapy -- Periodicals
Radiothérapie -- Périodiques
Cancérologie -- Périodiques
Tumeurs -- Périodiques
Electronic journals
616.9940642 - Journal URLs:
- http://www.sciencedirect.com/science/journal/01678140 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/01678140 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/01678140 ↗
http://www.estro.org/ ↗
http://www.elsevier.com/journals ↗
http://www.journals.elsevier.com/radiotherapy-and-oncology/ ↗ - DOI:
- 10.1016/j.radonc.2021.01.016 ↗
- Languages:
- English
- ISSNs:
- 0167-8140
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 7240.790000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 22555.xml