Characterizing surface viscoelastic integrity of ultra-fast photo-polymerized composites: Methods development. Issue 10 (October 2020)
- Record Type:
- Journal Article
- Title:
- Characterizing surface viscoelastic integrity of ultra-fast photo-polymerized composites: Methods development. Issue 10 (October 2020)
- Main Title:
- Characterizing surface viscoelastic integrity of ultra-fast photo-polymerized composites: Methods development
- Authors:
- Watts, David C.
Algamaiah, Hamad - Abstract:
- Highlights: The rapidly developing surface integrity of ultra-fast (3 s) photo-cure composites can be probed "immediately" by a new macroscopic indentation-creep methodology. PowerCure system and materials demonstrated an acceptable level of polymerization/property performance, despite the ultra-short irradiation times, as judged by this experimental criterion. Abstract: Objective: Resin-Composites are now available designed for polymerization using 3 s of intense light irradiation. The aim was to develop an experimental method to probe their surface viscoelastic integrity immediately following such rapid photo-cure via macroscopic surface indentation under constant stress as a function of time. Methods: Two bulk-fill composites (Ivoclar AG) were studied: Tetric PowerFill (PFill) and PowerFlow (PFlow). Split molds were used to fabricate cylindrical {4 mm (dia) × 4 mm} paste specimens, irradiated at 23 °C at 0 mm from the top surface with a Bluephase PowerCure LED-LCU, with 3 s or 5 s modes, emitting 3 and 2 W/cm 2, respectively. Post-irradiation specimens were immediately transferred to an apparatus equipped with a flat-ended indentor of 1.5 mm diameter. 14 MPa compressive stress at the indentor tip was applied centrally in < 2 min and maintained constant for 2 h. Indentation (I) magnitudes were recorded in real-time (t), with I(t) data re-expressed as % indentation relative to the 4 mm specimen height. After 2 h, the indentor was unloaded and indentation recovery wasHighlights: The rapidly developing surface integrity of ultra-fast (3 s) photo-cure composites can be probed "immediately" by a new macroscopic indentation-creep methodology. PowerCure system and materials demonstrated an acceptable level of polymerization/property performance, despite the ultra-short irradiation times, as judged by this experimental criterion. Abstract: Objective: Resin-Composites are now available designed for polymerization using 3 s of intense light irradiation. The aim was to develop an experimental method to probe their surface viscoelastic integrity immediately following such rapid photo-cure via macroscopic surface indentation under constant stress as a function of time. Methods: Two bulk-fill composites (Ivoclar AG) were studied: Tetric PowerFill (PFill) and PowerFlow (PFlow). Split molds were used to fabricate cylindrical {4 mm (dia) × 4 mm} paste specimens, irradiated at 23 °C at 0 mm from the top surface with a Bluephase PowerCure LED-LCU, with 3 s or 5 s modes, emitting 3 and 2 W/cm 2, respectively. Post-irradiation specimens were immediately transferred to an apparatus equipped with a flat-ended indentor of 1.5 mm diameter. 14 MPa compressive stress at the indentor tip was applied centrally in < 2 min and maintained constant for 2 h. Indentation (I) magnitudes were recorded in real-time (t), with I(t) data re-expressed as % indentation relative to the 4 mm specimen height. After 2 h, the indentor was unloaded and indentation recovery was monitored for a further 2 h. Parallel sets of measurements were made where indentation was delayed for 24 h. Further measurements were made with more conventional composites: EvoCeram Bulk Fill (ECeram) and Tetric EvoFlow Bulk Fill (EFlow). These were irradiated for 20 s at 1.2 W/cm 2 . Kinetic data were curve-fitted to exponential growth functions and key parameters analyzed by ANOVA and post-hoc tests (α = 0.05). Results: I(t) plots looked initially similar to bulk creep/recovery: rapid deformation plus viscoelastic response; then, upon unloading: rapid (elastic) recovery followed by partial viscoelastic recovery. However, unlike multiply irradiated and stored bulk-creep specimens, the present specimens were exposed to only 3 or 5 s "occlusal" irradiation; generating "hard" surfaces. Subsequently, during the 2 h indentation, the polymer matrix network continued to harden and consolidate. Upon initial loading, I(t) reached 2–3% indentation, depending upon the formulation. Upon unloading at 2 h, elastic recovery was only ca. 1 %. Delayed loading for 24 h, generated I(t) plots of significantly reduced magnitude. Most importantly, however, the I(t) plots for ECeram and EFlow, after 20 s irradiation, showed I(t) magnitudes quite comparable to the PFill and PFlow rapid-cure composites. Significance: Macroscopic indentation creep has been shown to be a workable procedure that can be applied to rapid-cure materials to assess their immediate surface integrity and developing viscoelastic characteristics. The applied stress of 14 MPa was relatively severe and the indentation/recovery profiles of PowerFill materials with only 3 or 5 s irradiation demonstrated comparability with their established 20 s cure siblings, evidencing the suitability of the PowerCure system for clinical application. … (more)
- Is Part Of:
- Dental materials. Volume 36:Issue 10(2020)
- Journal:
- Dental materials
- Issue:
- Volume 36:Issue 10(2020)
- Issue Display:
- Volume 36, Issue 10 (2020)
- Year:
- 2020
- Volume:
- 36
- Issue:
- 10
- Issue Sort Value:
- 2020-0036-0010-0000
- Page Start:
- 1255
- Page End:
- 1265
- Publication Date:
- 2020-10
- Subjects:
- Photopolymerization -- Dimethacrylate -- AFCT -- RAFT -- Resin-composite -- Indentation-creep -- Stretched-exponential -- Viscoelasticity -- Post-cure
Dentistry -- Periodicals
Dental materials -- Periodicals
617.695 - Journal URLs:
- http://www.elsevier.com/journals ↗
http://www.sciencedirect.com/science/journal/01095641/ ↗ - DOI:
- 10.1016/j.dental.2020.07.009 ↗
- Languages:
- English
- ISSNs:
- 0109-5641
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3553.365800
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 22552.xml