Assigning trabecular bone material properties in finite element models simulating the pelvis before and after the development of peri-prosthetic osteolytic lesions. (September 2022)
- Record Type:
- Journal Article
- Title:
- Assigning trabecular bone material properties in finite element models simulating the pelvis before and after the development of peri-prosthetic osteolytic lesions. (September 2022)
- Main Title:
- Assigning trabecular bone material properties in finite element models simulating the pelvis before and after the development of peri-prosthetic osteolytic lesions
- Authors:
- Grace, Thomas M.
Solomon, Lucian B.
Atkins, Gerald J.
Thewlis, Dominic
Taylor, Mark - Abstract:
- Abstract: Estimating strain distribution in the acetabulum before and after the development of peri-prosthetic osteolytic lesions secondary to total hip arthroplasty may assist with understanding the pathogenesis of this condition. This could be achieved by performing patient-specific finite element analysis of (1) total hip arthroplasty recipients with developed acetabular osteolytic lesions, and (2) models simulating the patient's pelvis and implant immediately after primary surgery. State of the art patient-specific total hip arthroplasty finite element analysis simulations obtain trabecular bone material properties from Hounsfield units within computed tomography (CT) scans of patients. However, this is not feasible when an implant is already in situ due to metal artefact disruption and, in turn, incorrectly reproduced Hounsfield units. Therefore, alternative methods of assigning trabecular bone material properties within such models were tested and strain results compared. It was found that assigning set material properties throughout the trabecular bone geometry was sufficient for the desired application. Simulating the primary implant and pelvis requires geometric and material based assumptions. Therefore, comparisons were made between strain values obtained from simulated primary models, from state of the art methods using material properties obtained from intact bone within a CT scan, and from models with osteolytic lesions. Strain values found using the finiteAbstract: Estimating strain distribution in the acetabulum before and after the development of peri-prosthetic osteolytic lesions secondary to total hip arthroplasty may assist with understanding the pathogenesis of this condition. This could be achieved by performing patient-specific finite element analysis of (1) total hip arthroplasty recipients with developed acetabular osteolytic lesions, and (2) models simulating the patient's pelvis and implant immediately after primary surgery. State of the art patient-specific total hip arthroplasty finite element analysis simulations obtain trabecular bone material properties from Hounsfield units within computed tomography (CT) scans of patients. However, this is not feasible when an implant is already in situ due to metal artefact disruption and, in turn, incorrectly reproduced Hounsfield units. Therefore, alternative methods of assigning trabecular bone material properties within such models were tested and strain results compared. It was found that assigning set material properties throughout the trabecular bone geometry was sufficient for the desired application. Simulating the primary implant and pelvis requires geometric and material based assumptions. Therefore, comparisons were made between strain values obtained from simulated primary models, from state of the art methods using material properties obtained from intact bone within a CT scan, and from models with osteolytic lesions. Strain values found using the finite element models simulating the pelvis before osteolytic lesion developed were considerably closer to those found using state of the art methods than those found for the bone loss models. These models could be used to determine relationships between strain distribution and factors such as bone loss. … (more)
- Is Part Of:
- Journal of the mechanical behavior of biomedical materials. Volume 133(2022)
- Journal:
- Journal of the mechanical behavior of biomedical materials
- Issue:
- Volume 133(2022)
- Issue Display:
- Volume 133, Issue 2022 (2022)
- Year:
- 2022
- Volume:
- 133
- Issue:
- 2022
- Issue Sort Value:
- 2022-0133-2022-0000
- Page Start:
- Page End:
- Publication Date:
- 2022-09
- Subjects:
- Peri-prosthetic osteolysis -- Finite element analysis -- Strain distribution -- Acetabulum -- Metal artefact
Biomedical materials -- Periodicals
Biomedical materials -- Mechanical properties -- Periodicals
Biomedical materials
Biomedical materials -- Mechanical properties
Periodicals
Electronic journals
610.28 - Journal URLs:
- http://www.sciencedirect.com/science/journal/17516161 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.jmbbm.2022.105311 ↗
- Languages:
- English
- ISSNs:
- 1751-6161
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5015.809000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 22544.xml