Spectra, ΓH*(10) and ΓKa produced by X-ray tubes, with Mo and Rh targets, in the diagnostic energy range. (October 2022)
- Record Type:
- Journal Article
- Title:
- Spectra, ΓH*(10) and ΓKa produced by X-ray tubes, with Mo and Rh targets, in the diagnostic energy range. (October 2022)
- Main Title:
- Spectra, ΓH*(10) and ΓKa produced by X-ray tubes, with Mo and Rh targets, in the diagnostic energy range
- Authors:
- Vega-Carrillo, Hector Rene
Campillo-Rivera, Guillermo Eduardo
Vazquez-Bañuelos, Joel
Garcia-Reyna, Mayra Guadalupe
Moreira-del Rio, Dania Estefania
Sanchez-Ortiz, Avelina
Baltazar-Raigosa, Antonio
Vasquez-Arteaga, Marcial - Abstract:
- Abstract: Voltage, current, target and filter in X-ray tubes define the X-ray spectrum; in turn, any dosimetric quantity depends on the spectrum. In the operation of an X-ray generator the dose is evaluated considering the contribution of leakage, scattered and direct beam contribution. For one X-ray unit using a voltage is important to know dose to 1 m per unit current (mA) and time (min); this feature is the Gamma factor (Γ). Using analog Monte Carlo methods, using the MCNP5 code, the objective of this work was to calculate the X-ray spectra and the Gamma factors for the ambient dose equivalent and air Kerma for X-units with two targets: Molybdenum and Rhodium and Aluminum filter. The X-rays are in the diagnostic energy range (70, 80, 90, 100, and 120 kV). Calculations were carried out in four positions (a, b, c and d ) along the useful beam, and to account the radiation leakage calculations include two positions (L1 and L2 ) around the shielding. The spectra average energy and the Gamma factors for air Kerma and ambient dose equivalent were calculated. Low energy photons are eliminated by the glass enclosure and the filter. To 1 m from the focal spot (positions d, L1 and L2 ) the larger photon fluence and the Gamma factors for air Kerma and ambient dose equivalent are larger when the target in the tube is Rh in comparison to those having a target of Mo. In position d all Γ factors are described by a third degree polynomial. Highlights: X-ray spectra produced by 70–120 kVAbstract: Voltage, current, target and filter in X-ray tubes define the X-ray spectrum; in turn, any dosimetric quantity depends on the spectrum. In the operation of an X-ray generator the dose is evaluated considering the contribution of leakage, scattered and direct beam contribution. For one X-ray unit using a voltage is important to know dose to 1 m per unit current (mA) and time (min); this feature is the Gamma factor (Γ). Using analog Monte Carlo methods, using the MCNP5 code, the objective of this work was to calculate the X-ray spectra and the Gamma factors for the ambient dose equivalent and air Kerma for X-units with two targets: Molybdenum and Rhodium and Aluminum filter. The X-rays are in the diagnostic energy range (70, 80, 90, 100, and 120 kV). Calculations were carried out in four positions (a, b, c and d ) along the useful beam, and to account the radiation leakage calculations include two positions (L1 and L2 ) around the shielding. The spectra average energy and the Gamma factors for air Kerma and ambient dose equivalent were calculated. Low energy photons are eliminated by the glass enclosure and the filter. To 1 m from the focal spot (positions d, L1 and L2 ) the larger photon fluence and the Gamma factors for air Kerma and ambient dose equivalent are larger when the target in the tube is Rh in comparison to those having a target of Mo. In position d all Γ factors are described by a third degree polynomial. Highlights: X-ray spectra produced by 70–120 kV x-ray tubes were estimated with Monte Carlo methods. X-ray tubes have two targets: Mo and Rh. The spectra were estimated in 4 positions along the useful beam. To account the leakage radiation the spectra were estimated in 2 positions. The Gamma factors for Ka and the H*(10) were calculated. … (more)
- Is Part Of:
- Radiation physics and chemistry. Volume 199(2022)
- Journal:
- Radiation physics and chemistry
- Issue:
- Volume 199(2022)
- Issue Display:
- Volume 199, Issue 2022 (2022)
- Year:
- 2022
- Volume:
- 199
- Issue:
- 2022
- Issue Sort Value:
- 2022-0199-2022-0000
- Page Start:
- Page End:
- Publication Date:
- 2022-10
- Subjects:
- X-rays -- Rh and Mo targets -- Spectrum -- Air kerma -- Ambient dose equivalent -- MCNP
Radiation chemistry -- Periodicals
Radiometry -- Periodicals
Radiation -- Periodicals
Chimie sous rayonnement -- Périodiques
539.2 - Journal URLs:
- http://www.sciencedirect.com/science/journal/0969806X ↗
http://www.elsevier.com/journals ↗
http://www.journals.elsevier.com/radiation-physics-and-chemistry/ ↗ - DOI:
- 10.1016/j.radphyschem.2022.110300 ↗
- Languages:
- English
- ISSNs:
- 0969-806X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 7227.984000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 22535.xml