Multi‐atlas–based auto‐segmentation for prostatic urethra using novel prediction of deformable image registration accuracy. Issue 7 (27th April 2020)
- Record Type:
- Journal Article
- Title:
- Multi‐atlas–based auto‐segmentation for prostatic urethra using novel prediction of deformable image registration accuracy. Issue 7 (27th April 2020)
- Main Title:
- Multi‐atlas–based auto‐segmentation for prostatic urethra using novel prediction of deformable image registration accuracy
- Authors:
- Takagi, Hisamichi
Kadoya, Noriyuki
Kajikawa, Tomohiro
Tanaka, Shohei
Takayama, Yoshiki
Chiba, Takahito
Ito, Kengo
Dobashi, Suguru
Takeda, Ken
Jingu, Keiichi - Abstract:
- Abstract : Purpose: Accurate identification of the prostatic urethra and bladder can help determine dosing and evaluate urinary toxicity during intensity‐modulated radiation therapy (IMRT) planning in patients with localized prostate cancer. However, it is challenging to locate the prostatic urethra in planning computed tomography (pCT). In the present study, we developed a multiatlas–based auto‐segmentation method for prostatic urethra identification using deformable image registration accuracy prediction with machine learning (ML) and assessed its feasibility. Methods: We examined 120 patients with prostate cancer treated with IMRT. All patients underwent temporary urinary catheter placement for identification and contouring of the prostatic urethra in pCT images (ground truth). Our method comprises the following three steps: (a) select four atlas datasets from the atlas datasets using the deformable image registration (DIR) accuracy prediction model, (b) deform them by structure‐based DIR, (3) and propagate urethra contour using displacement vector field calculated by the DIR. In (a), for identifying suitable datasets, we used the trained support vector machine regression (SVR) model and five feature descriptors (e.g., prostate volume) to increase DIR accuracy. This method was trained/validated using 100 patients and performance was evaluated within an independent test set of 20 patients. Fivefold cross‐validation was used to optimize the hype parameters of the DIRAbstract : Purpose: Accurate identification of the prostatic urethra and bladder can help determine dosing and evaluate urinary toxicity during intensity‐modulated radiation therapy (IMRT) planning in patients with localized prostate cancer. However, it is challenging to locate the prostatic urethra in planning computed tomography (pCT). In the present study, we developed a multiatlas–based auto‐segmentation method for prostatic urethra identification using deformable image registration accuracy prediction with machine learning (ML) and assessed its feasibility. Methods: We examined 120 patients with prostate cancer treated with IMRT. All patients underwent temporary urinary catheter placement for identification and contouring of the prostatic urethra in pCT images (ground truth). Our method comprises the following three steps: (a) select four atlas datasets from the atlas datasets using the deformable image registration (DIR) accuracy prediction model, (b) deform them by structure‐based DIR, (3) and propagate urethra contour using displacement vector field calculated by the DIR. In (a), for identifying suitable datasets, we used the trained support vector machine regression (SVR) model and five feature descriptors (e.g., prostate volume) to increase DIR accuracy. This method was trained/validated using 100 patients and performance was evaluated within an independent test set of 20 patients. Fivefold cross‐validation was used to optimize the hype parameters of the DIR accuracy prediction model. We assessed the accuracy of our method by comparing it with those of two others: Acostas method‐based patient selection (previous study method, by Acosta et al.), and the Waterman's method (defines the prostatic urethra based on the center of the prostate, by Waterman et al.). We used the centerlines distance (CLD) between the ground truth and the predicted prostatic urethra as the evaluation index. Results: The CLD in the entire prostatic urethra was 2.09 ± 0.89 mm (our proposed method), 2.77 ± 0.99 mm (Acosta et al., P = 0.022), and 3.47 ± 1.19 mm (Waterman et al., P < 0.001); our proposed method showed the highest accuracy. In segmented CLD, CLD in the top 1/3 segment was highly improved from that of Waterman et.al. and was slightly improved from that of Acosta et.al., with results of 2.49 ± 1.78 mm (our proposed method), 2.95 ± 1.75 mm (Acosta et al., P = 0.42), and 5.76 ± 3.09 mm (Waterman et al., P < 0.001). Conclusions: We developed a DIR accuracy prediction model–based multiatlas–based auto‐segmentation method for prostatic urethra identification. Our method identified prostatic urethra with mean error of 2.09 mm, likely due to combined effects of SVR model employment in patient selection, modified atlas dataset characteristics and DIR algorithm. Our method has potential utility in prostate cancer IMRT and can replace use of temporary indwelling urinary catheters. … (more)
- Is Part Of:
- Medical physics. Volume 47:Issue 7(2020)
- Journal:
- Medical physics
- Issue:
- Volume 47:Issue 7(2020)
- Issue Display:
- Volume 47, Issue 7 (2020)
- Year:
- 2020
- Volume:
- 47
- Issue:
- 7
- Issue Sort Value:
- 2020-0047-0007-0000
- Page Start:
- 3023
- Page End:
- 3031
- Publication Date:
- 2020-04-27
- Subjects:
- auto‐segmentation -- deformable image registration -- machine learning -- prostate cancer -- radiotherapy
Medical physics -- Periodicals
Medical physics
Geneeskunde
Natuurkunde
Toepassingen
Biophysics
Periodicals
Periodicals
Electronic journals
610.153 - Journal URLs:
- http://scitation.aip.org/content/aapm/journal/medphys ↗
https://aapm.onlinelibrary.wiley.com/journal/24734209 ↗
http://www.aip.org/ ↗ - DOI:
- 10.1002/mp.14154 ↗
- Languages:
- English
- ISSNs:
- 0094-2405
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5531.130000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 22508.xml