Correction for volume recombination in liquid ionization chambers at high dose‐per‐pulse. Issue 8 (14th June 2019)
- Record Type:
- Journal Article
- Title:
- Correction for volume recombination in liquid ionization chambers at high dose‐per‐pulse. Issue 8 (14th June 2019)
- Main Title:
- Correction for volume recombination in liquid ionization chambers at high dose‐per‐pulse
- Authors:
- Gotz, Malte
Ka, Leonhard
Tölli, Heikki
Pawelke, Jörg - Abstract:
- Abstract : Purpose: To determine the volume recombination at high dose‐per‐pulse in liquid ionization chambers (LIC) and to ascertain whether existing calculation methods verified in air‐filled chambers may be used to calculate a correction factor. Methods: Two LICs, one filled with 2, 2, 4‐trimethylpentane (isooctane) the other with tetramethylsilane (TMS), were irradiated in a pulsed, 20 MeV electron beam. Via reference measurements with a Faraday cup, the saturation correction for volume recombination was determined for dose‐per‐pulse values ranging from about 5 mGy to 1 Gy for both chambers at a pulse duration of 693 ns. In addition, the isooctane chamber was irradiated with pulses of varying duration, ranging from 5 ps to 10 ms, at a dose‐per‐pulse of about 76.5 mGy. The dose‐per‐pulse‐dependent measurements were compared to calculations based on Boag's models (with and without a free electron fraction), the two‐dose‐rate method, and a numerical calculation. The pulse duration dependent measurements were compared only to a numerical calculation that iteratively calculates the charge transport and loss in a 1D model of an ionization chamber. Results: In TMS only Boag's model with a free electron fraction and the numerical calculation are in good agreement with the experimental data. However, in isooctane, good agreement is observed between the experimental data, the numerical calculation as well as the two‐dose‐rate method, and Boag's model including a free electronAbstract : Purpose: To determine the volume recombination at high dose‐per‐pulse in liquid ionization chambers (LIC) and to ascertain whether existing calculation methods verified in air‐filled chambers may be used to calculate a correction factor. Methods: Two LICs, one filled with 2, 2, 4‐trimethylpentane (isooctane) the other with tetramethylsilane (TMS), were irradiated in a pulsed, 20 MeV electron beam. Via reference measurements with a Faraday cup, the saturation correction for volume recombination was determined for dose‐per‐pulse values ranging from about 5 mGy to 1 Gy for both chambers at a pulse duration of 693 ns. In addition, the isooctane chamber was irradiated with pulses of varying duration, ranging from 5 ps to 10 ms, at a dose‐per‐pulse of about 76.5 mGy. The dose‐per‐pulse‐dependent measurements were compared to calculations based on Boag's models (with and without a free electron fraction), the two‐dose‐rate method, and a numerical calculation. The pulse duration dependent measurements were compared only to a numerical calculation that iteratively calculates the charge transport and loss in a 1D model of an ionization chamber. Results: In TMS only Boag's model with a free electron fraction and the numerical calculation are in good agreement with the experimental data. However, in isooctane, good agreement is observed between the experimental data, the numerical calculation as well as the two‐dose‐rate method, and Boag's model including a free electron fraction. Only Boag's model without a free electron fraction shows a good agreement with lesser extend. Furthermore, the pulse duration‐dependent data for isooctane are well described by the numerical model. Conclusion: With isooctane as an active medium, a LIC could be directly used in a field with high dose‐per‐pulse utilizing the well‐established two‐dose‐rate method to correct the volume recombination. In addition, pulsed fields with variable pulse duration are easily modeled for this medium using a numerical calculation. Other media, as exemplified by the TMS‐filled chamber, might require additional considerations, such as including a fraction of free electrons in the consideration of volume recombination. … (more)
- Is Part Of:
- Medical physics. Volume 46:Issue 8(2019)
- Journal:
- Medical physics
- Issue:
- Volume 46:Issue 8(2019)
- Issue Display:
- Volume 46, Issue 8 (2019)
- Year:
- 2019
- Volume:
- 46
- Issue:
- 8
- Issue Sort Value:
- 2019-0046-0008-0000
- Page Start:
- 3692
- Page End:
- 3699
- Publication Date:
- 2019-06-14
- Subjects:
- collection efficency -- ionization chamber -- liquid ionization chamber -- saturation correction -- volume recombination
Medical physics -- Periodicals
Medical physics
Geneeskunde
Natuurkunde
Toepassingen
Biophysics
Periodicals
Periodicals
Electronic journals
610.153 - Journal URLs:
- http://scitation.aip.org/content/aapm/journal/medphys ↗
https://aapm.onlinelibrary.wiley.com/journal/24734209 ↗
http://www.aip.org/ ↗ - DOI:
- 10.1002/mp.13600 ↗
- Languages:
- English
- ISSNs:
- 0094-2405
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5531.130000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 22507.xml